DCN S4600 Series Manuale utente

S4600 series Installation manual Content
1
Content
Chapter 1 Introduction ............................................................. 1-1
1.1 Product Brief ................................................................................... 1-1
1.2 Physical Specifications .................................................................. 1-2
1.3 Description of Hardware ................................................................ 1-3
1.3.1 Front Panel............................................................................................... 1-3
1.3.2 Back Panel ............................................................................................... 1-5
1.3.3 Status LEDs ............................................................................................. 1-6
1.3.4 Front Panel Port Description ...............................................................1-12
Chapter 2 Hardware Installation .............................................. 2-1
2.1 Installation Notice ........................................................................... 2-1
2.1.1 Environmental Requirements ................................................................ 2-1
2.1.2 Installation Notice ................................................................................... 2-4
2.1.3 Security Warnings ................................................................................... 2-4
2.2 Installation Preparation .................................................................. 2-5
2.2.1 Verify the Package Contents .................................................................. 2-5
2.2.2 Required Tools and Materials ................................................................ 2-5
2.3 Installation Guide ............................................................................ 2-6
2.3.1 Installing the Switch ............................................................................... 2-6
2.3.2 Connecting Console ............................................................................... 2-7
2.3.3 SFP Transceiver Installation .................................................................. 2-7
2.3.4 Copper Cable/Fiber Cable Connection ................................................. 2-7
2.3.5 Power Supply Connection ..................................................................... 2-8

S4600 series Installation manual Chapter 1 Introduction
1-1
Chapter 1 Introduction
1.1 Product Brief
S4600 series switches are 1000Mb uplink layer 2 switches. S4600-10P-SI provides
10 fixed ports (8 10/100/1000Base-T fixed ports and 2 1000Mb SFP ports). S4600-28P-SI
provides 28 fixed ports (24 10/100/1000Base-T fixed ports and 4 1000Mb SFP ports).
S4600-52P-SI provides 52 fixed ports (48 10/100/1000Base-T fixed ports and 4 1000Mb
SFP ports). S4600-28P-P-SI provides 28 fixed ports (24 10/100/1000Base-T fixed ports
and 4 1000Mb SFP ports), supports 24 1000M ports of POE power supply.
S4600-28P-PL-SI provides 28 fixed ports (24 10/100/1000Base-T fixed ports and 4
1000Mb SFP ports), support 24 1000M ports of POE power supply. S4600-10P-P-SI
provides 10 fixed ports (8 10/100/1000Base-T fixed ports and 2 1000Mb SFP ports),
supports 8 1000Mb ports of POE power supply. S4600-28C-SI provides 28 fixed ports (24
10/100/1000Base-T fixed ports,2 1000Mb combo ports and 2 1000Mb SFP ports).S4600
series switches with advanced intelligent and secure features, can serve ideally as
distribution layer switches for the access device of campus networks, enterprise networks
and IP metropolitan networks.
S4600 series switches including the following 6 series switch:
Fig 1-1 S4600-10P-SI Switch
Fig 1-2 S4600-28P-SI Switch
Fig 1-3 S4600-52P-SI Switch

S4600 series Installation manual Chapter 1 Introduction
1-2
Fig 1-4 S4600-28P-P-SI Switch
Fig 1-5 S4600-28P-PL-SI Switch
Fig 1-6 S4600-10P-P-SI Switch
Fig 1-7 S4600-28C-SI Switch
1.2 Physical Specifications
Management Port
1 RJ-45 serial console port
AC Power Input
90 ~ 264VAC, 47Hz ~ 63Hz
Power Consumption
S4600-10P-SI: <6.92W
S4600-28P-SI: <18.3W
S4600-52P-SI: <40W
S4600-28P-P-SI: <390W
S4600-28P-PL-SI: <230W
S4600-10P-P-SI: <144W
S4600-28C-SI: <20W
Operating Temperature
-5 °C~50°C
Storage Temperature
-40°C~ 70°C

S4600 series Installation manual Chapter 1 Introduction
1-3
Relative Humidity
5%~95%, no condensate
Dimension
S4600-10P-SI: W×D×H 250mm×180mm×43.6mm
S4600-28P-SI: W×D×H 442mm×220mm×43.6mm
S4600-52P-SI: W×D×H 442mm×220mm×43.6mm
S4600-28P-P-SI: W×D×H 442mmX260mmx43.6mm
S4600-28P-PL-SI: W×D×H 442mmX280mmx43.6mm
S4600-10P-P-SI: W×D×H 340mmX200mmx43.6mm
S4600-28C-SI: W×D×H 442mm×230mm×43.6mm
Weight
S4600-10P-SI: 1.00±0.1kg
S4600-28P-SI: 2.20±0.1kg
S4600-52P-SI: 2.65±0.1kg
S4600-28P-P-SI: 3.90±0.1kg
S4600-28P-PL-SI: 3.63±0.1kg
S4600-10P-P-SI: 2.15±0.1kg
S4600-28C-SI: 2.20±0.1kg
Average no trouble time
At least 21, 0000 hours MTBF
1.3 Description of Hardware
1.3.1 Front Panel
S4600-10P-SI provides 8 10/100/1000Base-T ports, 2 1000Mb SFP ports, 1 Console
port, 1 system reset button, 12 LEDs, 1 220V AC power socket and 1 grounding screw.
The front panel of S4600-10P-SI is shown as follow:
Fig1-8 Front Panel of S4600-10P-SI
S4600-28P-SI provides 24 10/100/1000Base-T ports, 4 1000Mb SFP ports, 1
Console port, 1 system reset button, 30 LEDs, 1 220V AC power socket and 1 grounding
screw.
The front panel of S4600-28P-SI is shown as follow:

S4600 series Installation manual Chapter 1 Introduction
1-4
Fig 1-9 Front Panel of S4600-28P-SI
S4600-52P-SI provides 48 10/100/1000Base-T ports, 4 1000Mb SFP ports, 1
Console port, 1 system reset button, 54 LEDs.
The front panel of S4600-52P-SI series is shown as follow:
Fig 1-10 Front Panel of S4600-52P-SI
S4600-28P-P-SI provides 24 10/100/1000Base-T ports, 4 1000Mb SFP ports, 1
Console port, 1 system reset button, 30 LEDs.
The front panel of S4600-28P-P-SI series is shown as follow:
Fig 1-11 Front Panel of S4600-28P-P-SI
S4600-28P-PL-SI provides 24 10/100/1000Base-T ports, 4 1000Mb SFP ports, 1
Console port, 1 system reset button, 30 LEDs.
The front panel of S4600-28P-PL-SI series is shown as follow:
Fig 1-12 Front Panel of S4600-28P-PL-SI
S4600-10P-P-SI provides 8 10/100/1000Base-T ports, 2 1000Mb SFP ports, 1
Console port, 1 system reset button, 12 LEDs, 1 220V AC power socket and 1 grounding
screw.
The front panel of S4600-10P-P-SI series is shown as follow:
Fig 1-13 Front Panel of S4600-10P-P-SI
S4600-28C-SI provides 24 10/100/1000Base-T ports, 2 1000Mb combo ports,2
1000Mb SFP ports, 1 Console port, 1 system reset button, 28 LEDs, 1 220V AC power
socket and 1 grounding screw.
The front panel of S4600-28C-SI series is shown as follow:

S4600 series Installation manual Chapter 1 Introduction
1-5
Fig 1-14 Front Panel of S4600-28C-SI
1.3.2 Back Panel
The back panel of S4600-10P-SI is shown below:
Fig 1-15 Back Panel of S4600-10P-SI
The back panel of S4600-28P-SI is shown below:
Fig 1-16 Back Panel of S4600-28P-SI
The back panel of S4600-52P-SI is shown below, and there is 1 220V AC power
socket and 1 ground screw hole.
Fig 1-17 Back Panel of S4600-52P-SI
The back panel of S4600-28P-P-SI/S4600-28P-PL-SI is shown below, and there is 1
220V AC power socket and 1 ground screw hole.
Fig 1-18 Back Panel of S4600-28P-P-SI/S4600-28P-PL-SI
The back panel of S4600-10P-P-SI is shown below:
Fig 1-19 Back Panel of S4600-10P-P-SI
The back panel of S4600-28C-SI is shown below:
Fig 1-20 Back Panel of S4600-28C-S

S4600 series Installation manual Chapter 1 Introduction
1-6
1.3.3 Status LEDs
S4600 series switches include port indicator and system status indicator, as shown in
below and described in the following table.
1.3.3.1 Port Indicator Description
Fig 1-21 S4600-10P-SI LED diagram
Table 1-1 S4600-10P-SI port indicator description
Panel Symbol Status Description
Port1-8(Link/Act)
On (Green) The port is linked successfully
Flash (Green) The port is linked successfully, and
receive/send data
Off The port is not link
Port9/10(Link/Act)
On (Green) SFP port is linked successfully
Flash (Green) SFP port is linked successfully, and
receive/send data
Off SFP port is not link
Fig 1-22 S4600-28P-SI LED diagram
Table 1-2 S4600-28P-SI port indicator description
Panel Symbol Status Description
Port1-24(Link/Act)
On (Green) The port is linked successfully
Flash (Green) The port is linked successfully, and
receive/send data
Off The port is not link

S4600 series Installation manual Chapter 1 Introduction
1-7
Port25-28(Link/Act)
On (Green) SFP port is linked successfully
Flash (Green) SFP port is linked successfully, and
receive/send data
Off SFP port is not link
Fig 1-23 S4600-52P-SI LED diagram
Table 1-3 S4600-52P-SI port indicator description
Panel Symbol Status Description
Port1-48(Link/Act)
On (Green) The port is linked successfully
Flash (Green) The port is linked successfully, and
receive/send data
Off The port is not link
Port49-52(Link/Act)
On (Green) SFP port is linked successfully
Flash (Green) SFP port is linked successfully, and
receive/send data
Off SFP port is not link
Fig 1-24 S4600-28P-P-SI LED diagram
Table 1-4 S4600-28P-P-SI port indicator description
Panel Symbol Status Description
Port1-24(Link/Act)
On (Green) The port is linked successfully or PD
connected successfully
Flash (Green) The port is linked successfully, and
receive/send data
Off The port is not link and PD not connected
Port25/26/27/28(Link/A On (Green) SFP port is linked successfully

S4600 series Installation manual Chapter 1 Introduction
1-8
ct) Flash (Green) SFP port is linked successfully, and
receive/send data
Off SFP port is not link
Fig 1-25 S4600-28P-PL-SI LED diagram
Table 1-5 S4600-28P-PL-SI port indicator description
Panel Symbol Status Description
Port1-24(Link/Act)
On (Green) The port is linked successfully or PD
connected successfully
Flash (Green) The port is linked successfully, and
receive/send data
Off The port is not link and PD not connected
Port25/26/27/28(Link/A
ct)
On (Green) SFP port is linked successfully
Flash (Green) SFP port is linked successfully, and
receive/send data
Off SFP port is not link
Fig 1-26 S4600-10P-P-SI LED diagram
Table 1-6 S4600-10P-P-SI port indicator description
Panel Symbol Status Description
Port 1-8(Link/Act)
On (Green) The port is linked successfully or PD
connected successfully
Flash (Green)
The port is linked successfully, and
receive/send data
Off The port is not link and PD not
connected
Port 9/10(Link/Act)
On (Green) The port is linked successfully
Flash (Green)
The port is linked successfully, and
receive/send data
Off The port is not link

S4600 series Installation manual Chapter 1 Introduction
1-9
Fig 1-27 S4600-28C-SI LED diagram
Table 1-7 S4600-28C-SI port indicator description
Panel Symbol Status Description
Port1-24(Link/Act)
On (Green) The port is linked successfully
Flash (Green) The port is linked successfully, and
receive/send data
Off The port is not link
Port25-26(Link/Act)
On (Green) 1000Mb combo port is linked successfully
Flash (Green) 1000Mb combo port is linked successfully,
and receive/send data
Off 1000Mb combo port is not link
Port27-28(Link/Act)
On (Green) SFP port is linked successfully
Flash (Green) SFP port is linked successfully, and
receive/send data
Off SFP port is not link
1.3.3.2 System Status Indicator Description
Fig 1-28 S4600-10P-SI system LED diagram
Table 1-8 S4600-10P-SI system indicator description
LED Status Description
Power
On (Green) The internal power is operating normally
Off Power is off or error
DIAG
On (Green) Operating state is abnormal
Flash(Green) Operating state is normal
Off Power is off or system is abnormal