1. GENERAL INFORMATIONS and WARNINGS
- For emergancy conditions, we recommend you to put the keys to an accessible place (like car, bag etc.)
- If there is any problem with door or locking mechanism, first of all, those problems need to be solved. Door's mechanical
parts and locking mechanism should be working properly.
- If there is a problem with the device, first look to the troubleshooting part of this manual. If you cannot solve the
problem, contact with your dealer.
- Replace the batteries, if there is a battery warning. RECYCLE EMPTY BATTERIES!
- All the system need to be protected from water, direct sunlight and shocks.
- Place the batteries after installation of the system to the door. If the batteries are placed before the installation, auto-
rotating parts may cause injuries. WATCH YOUR FINGERS!
We would like to thank you for choosing this patented product. We hope you to enjoy it.
DESi Alarm and Security System Inc.

Controlling Options and Compatible Accessories
Wireless Fingerprint Reader
Wireless Keypad (with or without Bluetooth)
Wireless Auto-Locking Module
Wireless Home Automation Interface
Wireless Secretary Button
Remote Access Module
3
1.1. FEATURES OF THE DEVICE
Structure
Engraved block alluminum
Cylinder Length
(outside) 26 mm | 10 mm | 30 mm (inside)
Inside part can extensile up to 42 mm
(Different cylinder lengths are available)
Batteries and Battery Life
3x 3V CR123 type Lithium batteries.
Device is suitable to use with rechargable batteries.
According to tests done in DESi labratories, battery life of
the device is measured as follows:
2 years standby or
7.000 operations (locking or unlocking) for 3 turn locks
Remote Controller
434 Mhz Anti-duplicatiion rolling code remote controller
1.2. BOX CONTENT (may vary according to model number)
1x Wireless Motorized Cylinder (with keys)
1x Master Remote Controller
2x User Remote Controller
1x Installation screw and Hex key
User Manual

2. PARTS OF WIRELESS MOTORIZED CYLINDER and INSTALLATION
Cylinder
Handle
Handle Screw
4
Master RC
Full-Turn Locking
In the administrator menu;
Shift to next menu item or Confirm
1 Turn Locking
To enter administrator menu,
press 3 seconds.
In the administrator menu;
Enter to displayed menu item.
Display
Unlock and Open
In the administrator menu;
Shift to previous menu item

5
User RC
Set Screw
26 10 30
26 10 42
ADJUSTING CYLINDER LENGTH
Cylinder’s inner part can be extended by 12 mm.
- Open “handle screw” and remove the handle.
- Remove the batteries.
- Loosen the set screw with hex key out of the box.
- Extend the motorized part as needed by pulling.
- Tighten the set screw. Install the batteries and
handle. Check if it is working properly.
(if needed)
DETACHING / ATTACHING MOTOR AND
CYLINDER
- Open “handle screw” and remove the handle.
- Remove the batteries.
Set Screw
2
1
3
Full-Turn Locking
1 Turn Locking
Unlock and Open
Display
- Loosen the set screw with hex key out
of the box. Pull the motor part out.
To attach two parts, push the motor
properly in to cylinder and tighten the
set screw.

6
2.1. INSTALLATION OF MOTORIZED CYLINDER
This is the easiest installation. It is suitable for all kind of doors.
In some security doors, even if you remove cylinder screw, you cannot remove cylinder due to cramped installation of cylinder
defender. Follow the instructions below, for that kind of situations: (Recommended for professional installers.)
- Untighten screws of cylinder defender (don’t remove the screws)
- Remove cylinder screw and take out the old cylinder.
- Disassemble the motozied part from the cylinder. (see. p.5)
- Install the cylinder part to the door and tighten the cylinder screw.
- Tighten the screws of cylinder defender.
- Assemble the motorized part with cylinder. (see. p.5)
1.STEP
Remove
existing
cylinder.
2. STEP
Install
motorized
cylinder and
tighten
the screw
That’s
it!

7
3. ADMINISTRATIVE ACTIONS / SETTINGS
3.1. ENROLLING NEW REMOTE CONTROLLER
- Press 3rd button of master rc till “0" flashes on the display.
- Press 2nd button of master rc three times. “6" will be flashing on the display.
- Press 3rd button of master rc. “L” will be appeared on the display.
- Press 1st button of master rc. The cylinder will give a long (5 sec) and a short warning tone one
after the other.
- Just after the short warning tone, press 1st button of new remote controller till you hear 2 warning
tones from the cylinder.
In this way, the new remote controller will be enrolled to the device. Schematic representation of
operation is as follows:
3s 3X 5s Bp Bp Bp Bp
Master RC
i
Before using your motorized cylinder, Direction of locking/unlocking (p.9) and Number of turns (p.10) should
be adjusted. Otherwise, the device would not work properly.
(The remote controllers coming with Utopic are already enrolled)

8
Master RC
3.2. DELETING ALL THE REMOTE CONTROLLERS
- Press 3rd button of master rc till “0" flashes on the display.
- Press 2nd button of master rc two times. “7" will be flashing on the display.
- Press 3rd button of master rc. “d” will be shown on the display.
- Press 1st button of master rc. The motorized cylinder will give a long (10 sec) and two short warning
tone one after the other.
In this way, all the remote controllers (except the master rc) would be deleted from the device.
Schematic representation of operation is as follows:
3s 2X 10s Bp Bp Bp

9
Master RC
3.3. ADJUSTING THE DIRECTION OF LOCKING / UNLOCKING
- Press 3rd button of master rc till “0" flashes on the display.
- Press 1st button of master rc one time. “1" will be flashing on the display.
- Press 3rd button of master rc. Either “r” or “L” will be shown on the display.
- For counter-clockwise locking, choose “L” by pressing 1st button, for clockwise locking, choose
“r” by pressing 2nd button and than press 3rd button to confirm selection. Three lines will be
shown on the display.
After first locking or unlocking operation done by master rc, selected settings will be applied to
the system. Schematic representation of operation is as follows:
3s

10
3.4. ADJUSTING THE NUMBER OF TURNS
- Close the door and press 3rd button of master rc till “0" flashes on the display.
- Press 1st button of master rc two times. “2" will be flashing on the display.
- Press 3rd button of master rc. “o” will be shown on the display.
- Press 1st button. The motorized cylinder will give a long (3 sec) warning tone and it will lock and unlock the door.
In this way, motorized cylinder learns the number of turns of the locking mechanism.
Schematic representation of operation is as follows:
3s 2X 3s Bp Lock and Unlock
3.5. REPORTING NUMBER OF REMOTE CONTROLLERS IN THE MEMORY
- Press 3rd button of master rc till “0" flashes on the display.
- Press 2nd button of master rc one time. “8" will be flashing on the display.
- Press 3rd button of master rc. “C” will be shown on the display.
- Press 1st button of master rc.
The motorized cylinder reports number of remote controllers (and other wireless devices enrolled to the
motorized cylinder) as warning signals. Schematic representation of operation is as follows:
3s Bp Bp
...