5
Firestop Supports are
currently manufactured for
pipe sizes of 3" through 12"
only. Larger sizes may be
locallyfabricatedfromsheet
metal, provided that the
mandatory 1-inch clearance
is maintained, the pipe is
adequatelysupported,andthe
installation is acceptable to
Local Authorities. In
multistory buildings, a Firestop/
Spacer must be provided at every
floor /ceiling level other than the
firstfloorwhichrequiresasupport.
4.WallThimble. Forathrough-
the-wall system, install the Wall
Thimble,asshowninFigure5. The
Wall Thimble is designed to ac-
commodate walls up to 6 inches
thick. If you have thicker walls, a
sleeve extension should be fabri-
cated and attached to the existing
sleeve . Do not fill the air space
between the B-vent Pipe Section
andtheWallThimblewithinsula-
tion,althoughanRTV-typesealant
may be applied around the flange
and nail heads if desired.
5.PipeAssembly. Sectionsof
SimpsonDura-Ventroundpipeare
joinedtogetherbyliningup the fe-
maleendofthelockinglugwiththe
maleendslot,pushingthemtogether,
andturningclockwisetotwistlock.
Refer to Figure 9. Sheet metal
screwsarenotneededfor3"through
PIPE SIZE STOCK NUMBER OF
CEILING SUPPORT FRAMED INSIDE
DIMENSIONS (X & Y)
FIG 4
3 INCH 1440 7-3/8" X 7-3/8"
4 INCH 1441 7-3/8" X 7-3/8"
5 INCH 1442 9-1/8" X 9-1/8"
6 INCH 1443 9-1/8" X 9-1/8"
7 INCH 1444 11-1/8" X 11-1/8"
8 INCH 1445 11-1/8" X 11-1/8"
10 INCH 1446 13-1/8" X 13-1/8"
12 INCH 1447 13-1/8" X 13-1/8"
Table1
EXISTING
SHEET ROCK
FRAMINGMEMBERS
REQUIRED FOR
SUPPORT
EXISTING
JOISTS
Fig 4
Fig 5