Dynabrade DYNA-FAST 62110 Manuale utente

WE LISTEN. WE OBSERVE. WE OPTIMIZE.
DYNA-FAST
FOOT ACTIVATED SCREENING THERMOMETER
62110
Forehead
Thermometer
Included
62111
Forehead
Thermometer
Not Included
ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
PD20-07

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
2
TABLE OF CONTENTS
1. Title 1
2. Contents 2
3. Description 3
4. Intended Use 3
5. Foreseeable Misuse 3
6. Important Safety Instructions 4
7. Set Up
7.1 Wall Mounting 4
7.2 Thermometer Installation 6
7.3 Battery Installation 7
7.4 Cable Adjustment 8
8. Operation 9
9. Maintenance 10
10.Dimensions 10
11.Parts Diagram
11.1 Lower Housing 11
11.2 Upper Housing 12
11.3 Cable 13
12.Warranty 14

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
3
3. DESCRIPTION
The Dynabrade Foot Activated Screening Thermometer (DYNA-FAST) is a hands-free system for
independently checking body temperature. The system’s foot activated switch prevents the transfer
of germs from person to person by surface contact, and its self-service design allows correct social
distancing to be maintained since a dedicated thermometer operator is not required.
The DYNA-FAST secures an infrared forehead thermometer and uses a foot pedal, cable, and linkage
to actuate the thermometer’s switch. The rearward facing temperature reading is displayed with an
arrangement of two mirrors.
4. INTENDED USE
The DYNA-FAST is intended to be used as a body temperature screening system to let individuals
privately see their own temperature. The DYNA-FAST is for indoor use only and must be securely wall
mounted adjacent to an Instructions for Use poster. The DYNA-FAST is for use with a non-contact,
front switch, forehead thermometer. The DYNA-FAST is for individuals with the ability to use their foot
to press a switch at oor level while their forehead is aligned with the thermometer.
5. FORESEEABLE MISUSE
Misuse could include but isn’t limited to the following:
• Set up and installation without reading this manual
• Using the DYNA-FAST without reading this manual
• Un-secure wall mounting
• Instructions for Use not posted
• Outdoor use
• Touching the DYNA-FAST with hands during use
• Misalignment of forehead to thermometer during use

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
4
6. IMPORTANT SAFETY INSTRUCTIONS
READ ALL PARTS OF THIS MANUAL CAREFULLY BEFORE USE AND KEEP FOR FUTURE REFERENCE
Denitions:
WARNING
Indicates a hazardous situation that, if not avoided, could result in death
or serious injury.
Indicates a hazardous situation that, if not avoided, could result in minor
or moderate injury.
WARNING
Cancer and Reproductive Harm – www.P65Warnings.ca.gov
7. SET-UP
7.1 Wall Mounting (Figure 1)
1) Securely fasten the UPPER HOUSING to a wall using #10 fasteners (not included).
Position UPPER HOUSING to accommodate the height of the shortest anticipated user.
To avoid impact injury, secure UPPER HOUSING to wall
To prevent error, do not mount in direct sunlight or in draft
2) Securely fasten the LOWER HOUSING to the wall using #10 fasteners (not included).
Mount at oor level, centered below the UPPER HOUSING within +/- 1 inch.
3) Securely fasten the CABLE to the wall using supplied LOOP CLAMPS.
To avoid entanglement or tripping injury, secure LOWER HOUSING and CABLE to wall.

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
5
7. SET-UP
7.1 Wall Mounting (Figure 1)

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
6
7. SET-UP
7.2 Forehead Thermometer Installation (Figure 2)
1) Loosen FRONT and REAR LOCKING NUTS (3/8” wrench) CLAMPING SCREWS (#2 Phillips screwdriver)
2) Position FRONT CLIPS to align forehead thermometer SWITCH with TRIGGER then tighten FRONT LOCKING NUTS
3) Tighten CLAMPING SCREWS to secure forehead thermometer
4) Tighten REAR LOCKING NUTS
Figure 2

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
7
7. SET-UP
7.3 Forehead Thermometer Battery Installation (Figure 3)
1) Conrm size and polarity of batteries and install as indicated on the forehead thermometer housing
2) Follow local guidelines when disposing of used batteries
Figure 3

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
8
7. SET-UP
7.4 Cable Adjustment (Figure 4)
1) Loosen NUT to allow CABLE adjustment. SPRING will pull TRIGGER BAR up to the STOP
2) Pull CABLE up to remove slack, then tighten NUT to secure CABLE
Figure 4

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
9
8. OPERATION
(Figure 5)
1) Align forehead 2 inches (50mm) from forehead thermometer
To avoid error, do not align with hair or perspiration
2) Press foot switch
3) Read temperature output in mirror
Figure 5

ABRASIVE POWER TOOLS AND PROCESS SOLUTIONS SINCE 1969 Dynabrade, Inc. |8989 Sheridan Dr. |Clarence, NY 14031 |dynabrade.com
10
9. MAINTENANCE
1) Clean surfaces with a damp cloth
2) Do not use abrasive cleaners
3) Clean mirrors with glass cleaner
10. DIMENSIONS