Edge-Core VST3305 Manuale utente


Attention: This is draft e
VST3300 Series
Quick Installation Guide
Edition 1.0
Update:2006/04/25
DOC No.: 9172018701

Quick Installation Guide
1
Table of Contents
1. Safety Instructions..................................................................................3
2. Package Contents and Related Environmental Requirements...............4
2.1 Contents...........................................................................................................4
2.2 Hardware and network requirements................................................................5
3. Device Figure .........................................................................................6
3.1 Panel ................................................................................................................6
3.2 LED indicators..................................................................................................6
3.3 Connectors.......................................................................................................6
4. Hardware Installation..............................................................................7
4.1 General Connection..........................................................................................7
4.1.1 Connection with Telephone Line................................................................................7
4.1.2 Connection with Network Cables...............................................................................8
4.1.3 Connection with Console Cable.................................................................................8
4.2 Connection of 16 Port Model............................................................................9
4.2.1 Installation of Modules...............................................................................................9
4.2.2 Module Numbering ...................................................................................................9
4.2.3 Use IDC Connector....................................................................................................9
4.2.4 Connection between IDC Connector and Phone Set...............................................10
4.3 Connection of Basic Structure ........................................................................ 11
5. Initial Settings for a Single Device........................................................12
5.1 Phone Set Configuration (Phone Set Programming Mode)..........................122
5.2 Configuration of Telecom Region ID.............................................................122
5.3 Configuration of IPAddress............................................................................13
5.4 Configuration of My Phone Number ...............................................................13
5.5 Restart............................................................................................................14
6. Configuration of Router ........................................................................15
6.1 Connection to Internet ....................................................................................15
6.1.1 Configuration............................................................................................................15
6.2 Open Server Port to Penetrate NAT ...............................................................18

Quick Installation Guide
2
7. Checking before Dialing .....................................................................211
7.1 Enter Web to Verify.........................................................................................21
7.2 Check Related Configurations........................................................................22
7.2.1 Basic Information.....................................................................................................22
7.2.2 IP Setting .................................................................................................................23
7.3 Restart............................................................................................................23
7.4 Check LED Status...........................................................................................24
7.5 Trouble Shooting ............................................................................................25
7.5.1 The configuration is not correct................................................................................25
7.5.2 LED Errors...............................................................................................................25
8. Making Phone Calls..............................................................................26
8.1 Dialing between Extension .............................................................................26
8.2 Make and Answer Trunk Calls........................................................................26
8.3 Making a Call to the Distributor.......................................................................27
9. Other Important Notices .......................................................................29
9.1 Change Password ..........................................................................................29
9.1.1 How To Use Console or Telnet.................................................................................29
9.1.2 Change Web Password...........................................................................................30
9.1.3 Change Password of FTP, Telnet and Console .......................................................31
9.2 Change Service Port ......................................................................................31
9.2.1 Change Service Port of Http, Console, FTP............................................................31
9.2.2 How to Enter System with Customized Service Port...............................................32
9.3 Recordable Greetings.....................................................................................32
9.4 Other References ...........................................................................................33

Quick Installation Guide
3
1.Safety Instructions
1. Do not attempt to service the product yourself. Any servicing of this product should be
referred to qualified service personnel.
2. To avoid electric shock, do not put your finger, pin, wire or any other metal objects
into vents and gaps.
3. To avoid accidental fire or electric shock, do not twist power cord or place it under
heavy objects.
4. This product should be connected to a power supply of the type described in the
operating instructions or as marked on the device.
5. To avoid hazard to children, dispose of the product’s plastic packaging carefully.
6. The phone line from Telecom Company or traditional PBX should always be
connected to the LINE or FXO connector. It should not be connected to the
PHONE/FAX or FXS connector as it may cause damage to the product.
Please read all instructions before using this product to prevent damage to this
product. If the document you read is in digital format, print out the whole manual
for easy installation.
Warning

Quick Installation Guide
4
2.Package Contents and Related Environmental
Requirements
2.1 Contents
Includes:
VST3300 Series Device x 1
SIP Channels (Default)Model Name Analog Channels SIP Lines SIP Trunks
VST3305 3 1 FXO + 2 FXS 8 2
VST3306A 4 2 FXO + 2 FXS 12 2
VST3306B 4 4 FXS 12 2
VST3306C 4 4 FXO 12 2
VST3318A 16 8 FXO + 8FXS 24 2
VST3318D 16 4 FXO + 12 FXS 24 2
VST3318E 16 12 FXO + 4 FXS 24 2
Power Cord x 1
Console Cable x 1
Manual/Tools CD x 1
RJ-45 LAN Cable x 1
RJ-11 Phone Cable x 1
Rubber Foot Pads x 1
Dedicated accessories for VST3318:
Plug-in Modules
Modules Description
MP3208+ 4FXS + 4FXO
MP3008+ 8FXS
MP3108+ 8FXO
Rack mounting accessories for standard rack
IDC connectors x 4

Quick Installation Guide
5
2.2 Hardware and network requirements
This product requires the basic environment listed below.
1. Broadband IP network, fixed IP (Public or Private IP) is suggested. This device may
connect to a router using dynamic IP (PPPoE).
2. Bi-directional, 64~512 Kbps bandwidth or more is recommended depending on port
usage. (Each call occupies about 40 Kbps. Make estimations for concurrent calls and
occasional poor network conditions.)
Note: If a fixed public IP address (Public or Private IP) is not used, this system can still
work. In this case, the factory default value will not be suitable. Please refer to the
operation manual or contact your distributor for more assistance.

Quick Installation Guide
6
3.Device Figure
This device can be cascaded or integrated into a network. The diagram below shows a
single unit and its LED indicators.
3.1 Panel
The example below is the 16 ports model (VST3318)
3.2 LED indicators
Please refer to section 7.4 Check LED Status for the meaning of each LED indicator and
status of the device.
3.3 Connectors
Terminal Label Description
FXS For analog phone sets or FAX machines
FXO For public lines or trunk from Analog PBX
Voice
BROADCAST (for
VST3305 only) For an amplifier, speakers or earphones
To WAN (MDI-X) RJ-45 MDI-X terminal, for WANNetwork
To LAN (MDI) RJ-45 MDI terminal, for LAN
CDR For Call Detail Records
RS-232 CONSOLE For system console management

Quick Installation Guide
7
4.Hardware Installation
4.1 General Connection
4.1.1 Connection of Telephone Line
There are 2-wire and 4-wire telephone lines. A 2-wire line is OK for this machine. The
connector type is RJ-11.
♦The FXS or Phone port of this machine can connect to phone set or Trunk card/FXO
port of an analog PBX only.
♦The FXO or Line port of this machine can connect to the PSTN from a CO or a Line
card/FXS from an Analog PBX only.
Attention: VST3300 Series extensions will seize the highest FXO port number first when
trunk calls are made. Therefore, connect the FXO ports of the VST3300 Series from
highest number downward. For example, on the 16 port model, please follow the
sequence 16→15→14→13→. For port position arrangement refer to 4.2.2 Module
Numbering
Attention: Incorrect connection of the FXS/Phone ports of this machine to the PSTN or
Line card of an analog PBX will damage this machine or the analog PBX.
V
S
T
3300 PBX
FXS/
Phone
FXO/
Trun
k
V
S
T
3300
PBX FXO/
Line
Line/
FXS
V
S
T
3300
FXS/
Phone
V
S
T
3300
PSTN
FXO/
Line
Larger ports
numbers first

Quick Installation Guide
8
4.1.2 Connection of Network Cables
There are 2 kinds of LAN cables, straight through cables and crossover cables. Both
connectors are RJ-45 type although they appear the same. Using the wrong cable type
will not damage the machine. The figure below is for your reference.
Confirm the following:
zThe Link/Act LED of the PC network card is ON or blinking.
zLNK/ACT LED of MDI or MDI-X port of VST3300 Series is ON or blinking.
Otherwise, change the port or LAN cable and retry it again
Note: PC connection is for the configuration of this product. When configuration is
complete, no PC is required to make or accept calls, the PC can then be shut
down.
4.1.3 Connection of Console Cable
The Console port is available for a PC connection and can be used to make initial
configurations such as for IP address and regional ID. Some initial values have already
been set on this machine. If connected to a LAN, the console cable is not required.
VST3300
Internet/LAN
PC
MDI/MDI-X
Altri manuali per VST3305
1
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali Edge-Core Centralino
Manuali Centralino popolari di altre marche

Grandstream Networks
Grandstream Networks UCM6208 Manuale utente

ATCOM
ATCOM IPPBX IP02 Manuale utente

Panasonic
Panasonic KX-TVS50 - 2 Port Voicemail System Manuale utente

bintec elmeg
bintec elmeg elmeg hybird 600 Manuale utente

Panasonic
Panasonic KX-NS300 Manuale utente

MCK
MCK EXTender PBXgateway Manuale utente