EdilKamin PHOENIX 1115620 Manuale utente

REMOTE CONTROL
PHOENIX
1115620
Please refer to web site, technical area

2
ENGLISH
Characteristics:
Frequency 2.4 GHz - Power supply 2 AA slimline 1.5 VDC batteries.
Dimensions 66x29x144mm; weight 105 without batteries. 2” LCD Display.
Must be kept within a temperature range of -5°C to 50°C.
USER INSTRUCTIONS: REMOTE CONTROL
USER
Risk of explosion if the batteries are replaced with other batteries of an incorrect type.
The remote control has a probe which reads the temperature and communicates with the product for automatic
management.
Day, Date and Time
DECREASE
INCREASE
ON-OFF
switch-on/switch-off
AUTO/MAN
MENU
RELAX
Room temperature
Operating procedure
(e.g. Manual P5)
or set temperature
Pellet reserve
Output power
Ventilation
- Lock/ Unlock keys
By pressing and for 2” at the same time (prolonged press) the keyboard is locked.
If you press any key, the padlock symbol appears on the main display.

3
ENGLISH
USER INSTRUCTIONS: REMOTE CONTROL
- Energy saving
After 20 seconds of non-use the backlighting switches off and after a further 10 seconds or so the display
switches off completely.
USER
DAY AND TIME
WARNING Symbols
MODE:
Auto or Timer
INFO Bar SET or ALARM or
OFF
FLAME and FAN
Symbols
ROOM
TEMPERATURE
- ON-OFF
- INCREASE
- DECREASE
- CONFIRM OK
- MENU - AUTO/MAN (prolonged press) – SCROLLING L
- RETURN - RELAX (prolonged press) – SCROLLING R
Speed 1 Speed 2 Speed 3
Speed 4 Speed 5 AUTOMATIC Speed
Relax Function active

4
ENGLISH
FOR THE TECHNICIAN
INSTALLER
Installation in the place of Asola
To install the Remote control update:
- the Firmware on the basic circuit board with a
version from PELE1711 onwards
- complete APF, if the installed revision is below rev 103.
In order to do that, copy the updated APF of the
product in the USB pen-drive supplied with the
Remote control (and containing the firmware).
Insert the USB pen-drive into the product’s USB
socket and supply power to the product. After
about 30 seconds, a beep will signal that the
reprogramming has completed successfully.
At this point the Phoenix must be linked with the
product.
The remote control will show this display.
To link the Remote control with the product, disconnect
and restore power to the basic circuit board.
When you hear the beep, press the key on the remote
control . This display will appear:
When the Remote control finds a compatible
communication, the linking procedure will terminate
automatically.
If the remote control does not find any compatible
communication, it will again display “No network”.

5
ENGLISH
FOR THE TECHNICIAN
INSTALLER
Disassociating the remote control from a
circuit board - LEAVE
If the remote control has already been linked to
one circuit board and must be linked to a different
circuit board (for example if a circuit board has been
replaced), the “No network” icon will appear on the
display.
To link the remote control to the new basic circuit board,
you need to perform the disassociation procedure.
The procedure can be performed via the Technical
Menu or, if there is no communication, in the following
manner:
press the “Return” key for at least 10 seconds.
The following display will appear
and the disassociation can be confirmed with the
key
The remote control will display “No network” and it is
then possible to proceed with a new linking.
If no buttons are pressed, the Remote control will go to
“Energy Saving” while waiting for confirmation.
Once the Phoenix has been linked to the product, the
remote control proposes the update of the APF, which
requires confirmation.

6
ENGLISH
OPERATION
Mode Settable parameters
MANUAL • power level
• ventilation level (if there are
two or more fans, they can be
adjusted separately)*
AUTOMATIC • desired room temperature
• ventilation level *
CRONO • desired room temperature,
selected per day of the week
• ventilation level*
* when lowering the ventilation, the product can also
automatically modulate its power to maintain maximum
efficiency.
USER INSTRUCTIONS
USER
The product also has the following supplementary
functions.
Function Modes in which
it can be acti-
vated
What it does
Stand-By automatic crono when the desired
temperature is
reached, the
product switches
off and then back
on again when the
temperature drops
RELAX manual
automatic crono
enables natural
convection mode
(fan off), thus
reducing the power
EASY
TIMER
manual
automatic
is used to
programme the
switching off/on
after a set number
of hours (maximum
12 hours)
OPTIONAL CONNECTIONS
The technician can supply, on request:
• external thermostat;
• telephone dialler;
• probes/thermostats for managing the ducting fans
(if present on the purchased model).
1) Ex.: air product in Automatic with 3 fans in AUTO, Power P5, Set Room 18.5°C
2) Ex.: air product in Manual with 3 fans in V3, Power P3.
3) Ex.: air product with Crono active and Fans in V5, Power P5, Set Room = 22°C.
1) 2) 3)

7
ENGLISH
USER INSTRUCTIONS
USER
POWER ON/POWER OFF
These operations will take a few minutes, during which the flame must appear or extinguish. Simply wait without
taking any action.
During switch-off,
the display shows the text “OFF”.
- CLEAN in the cleaning phase
- START in the Load Pellets and Start 1 phases
- START in the Start 2 phase with the flame symbol
- WARM UP in the Warm Up phase with the flame symbol
If timer scheduling is active:
The switching on and off of the product can be forced with the Crono active, by prolonged pressing of the
button.
The switching on and off force the move from Crono to Automatic mode with the pre-set Set Room and Ventilation.
During switch-on:

8
ENGLISH
In AUTOMATIC mode:
Setting the Room Temperature (read by the remote control, which should be located in the room where the
product is installed). Modify the desired temperature using the “+” and “–” buttons.
AUTOMATIC MANUAL
Press any button and the display will activate, then press the button
With CRONO active, it is not possible on the main display to change the choice of Temperature level (T1, T2 or T3) or
the value of T1, T2 or T3. To do so, you need to access the Menu.
The or buttons are disabled.
The flashing “SET” or “MAN” symbol appears; the operating Mode symbols and the Power level and Ventilation
symbols disappear.
The Set is modified with the or buttons and the setting is confirmed with the button or by waiting
5 seconds without pressing any buttons.
USER INSTRUCTIONS
USER
USER CONTROLS ON REMOTE CONTROL
ON/OFF
Hold the ON/OFF button down to switch the product ON.
AUTOMATIC and MANUAL setting
Press the AUTO/MAN button for a few seconds to switch from manual to automatic mode or vice versa.
NOTE
or WAIT

9
ENGLISH
If the product is in AUTOMATIC mode and the room temperature probes in the ducted zones are
present and activated, you can press the button to confirm the main Set Room setting and enter the
setting of the Set Room for the ducted zones 2 and 3 by displaying the Room Temperature of the ducted zone and
the related Set
The flashing “SET”or “MAN” symbol appears; the operating Mode symbols and the Power level and Ventilation
symbols disappear.
The Set is modified with the or buttons and the setting is confirmed with the button or by waiting
5 seconds without pressing any buttons.
USER INSTRUCTIONS
USER
Press any button and the display will activate, then press the button
- FAN ADJUSTMENT
Fan ventilation adjustment can be accessed from the Menu. See the relevant section
In MANUAL mode:
Setting of the power
Modify the power level (displayed by the flame symbol) using the “+” and “–” buttons.
WAIT
WAIT
or WAIT

10
ENGLISH
USER INSTRUCTIONS
- RELAX FUNCTION
Natural convection function (without ventilation) with automatic power limiting.
This function is available in all modes: automatic, manual and crono.
Press the button for two seconds to activate the Relax function.
Activation is indicated on the display with the RELAX symbol instead of the frontal fan.
Again by prolonged pressing of the button, the function is disabled.
The product reduces its power output and after a few minutes switches the fan off too.
USER