EFOY DuoCartSwitch DCS 1 Manuale utente

User Manual
Bedienungsanleitung
DuoCartSwitch DCS 1
EFOY Pro 800 / 800 Duo / 2400 / 2400 Duo
EFOY Pro 600 / 1200 / 1600 / 2200 / 2200 XT EN
DE

User Manual 2
Bedienungsanleitung 21
EN
DE

1. Table of contents
2
1. Table of contents 2
2. Introduction 3
2.1 Introduction 3
2.2 Safety Information 4
2.3 Normal Operation 5
2.4 Improper use 6
2.5 Declaration of conformity 6
2.6 Seals of approval 6
2.7 Disposal 6
2.8 Specification label 7
3. Configuration 8
3.1 Standard Equipment 8
3.2 Overview 8
3.3 Specifications DuoCartSwitch 8
4. Installation 9
4.1 Installation 9
4.2 Connecting the fuel cartridges 10
4.3 Connection to the EFOY Pro 11
5. Operation 12
5.1 Activate the DuoCartSwitch 12
5.2 Operate the DuoCartSwitch 15
5.3 Switching of DuoCartSwitch 19
6. FAQs 20
6.1 FAQs 20
1. Table of contents

2. Introduction
3
2. Introduction
2.1 Introduction
Thank you for purchasing an EFOY product. We hope that you
will enjoy your new unit.
Please read these instructions as well as the user manual of
the EFOY Pro Series before using the DuoCartSwitch.
Use the DuoCartSwitch only with EFOY Pro fuel cells.
Please note the instructions and the warnings in both
manuals.
Should you have any questions about installation or operation,
please contact the EFOY hotline.
Headquarter Europe: North America:
SFC Energy AG SFC Energy, Inc.
Eugen-Saenger-Ring 7 7632 Standish Place
D-85649 Brunnthal-Nord Rockville, MD 20855
Phone: +49 89 - 673 592 555 Phone:+1 240 – 328 6688
Fax: +49 89 - 673 592 369 Fax: +1 240 – 328 6694
service@sfc.com service-USA@sfc.com
www.efoy-pro.com
Freecall: 00800 732 762 78*
*The toll-free number via landline is available in the following countries:
Germany, Belgium, Denmark, France, Great Britain, Italy, the Netherlands,
Norway, Austria, Sweden, Switzerland and Spain.

2. Introduction
4
2.2 Safety Information
Read the user manual before commissioning the fuel
cell, and keep the user manual close to the device at
all times.
Follow all of the instructions in this user manual.
WARNING!
In exceptional cases, the waste gases emitted by the
device may contain substances that are harmful to
health!
Do not inhale waste gases directly for prolonged
periods. Instead, use the exhaust tube provided to
route the waste gas into the open air.
WARNING!
Damage in the event of an accident; risk of injury!
EFOY fuel cells and EFOY fuel cartridges must be
securely fastened to prevent damage in the event of an
accident.
CAUTION!
The fuel cell is not water-tight!
Ensure that no water can enter the fuel cell.
DANGER!
Leakage of methanol fumes poses a fire hazard!
Do not smoke when replacing the EFOY fuel cartridge
and do not expose it to other ignition sources! Protect
EFOY fuel cartridges from temperatures exceeding
50 °C / 122 °F.

2. Introduction
5
WARNING!
Methanol is highly flammable!
You receive methanol in safe, tested EFOY fuel
cartridges, which prevent the contents from escaping if
used correctly.
The storage and transport of methanol may be subject
to statutory regulations.
Fore more information, refer to the safety sheet on
methanol, available on our website at
http://www.efoy-pro.com
WARNING!
Methanol is toxic when inhaled, swallowed or allowed
to come into contact with the skin. Inhaling and
swallowing methanol or allowing it to come into
contact with your skin carries a serious risk of
irreversible damage.
Call a doctor immediately if you have direct physical
contact with the substance, in the event of an accident,
or if you feel unwell, and show the doctor the fuel
cartridge label, the methanol safety data sheet or the
user manual.
CAUTION!
Impurities in methanol!
Original EFOY fuel cartridges contain methanol that
has been approved by SFC. Even slight impurities or
foreign particles in commercially available methanol
may cause irreversible damage to the device, and may
nullify the warranty or guarantee.
Use only original EFOY fuel cartridges!
2.3 Normal Operation
The DuoCartSwitch is used to operate two EFOY cartridges
with one EFOY Pro fuel connector. The switching valve turns
automatically from the operating cartridge to the reserve
cartridge. The DuoCartSwitch is only approved to be used

2. Introduction
6
with EFOY cartridges.
2.4 Improper use
The DuoCartSwitch can only be used with EFOY cartridges.
Do not use any other identical cartridge. No changes to the
whole system are allowed.
2.5 Declaration of conformity
SFC Energy AG, Eugen-Saenger-Ring 7, 85649 Brunnthal-
Nord declares that the DuoCartSwtich DCS1 conforms to the
European Community’s 2004/108/EG guidelines for electro-
magnetic compatibility. The following norms apply: DIN EN
61000-6-1, DIN EN 61000-6-3
2.6 Seals of approval
The DuoCartSwitch has undergone voluntary testing by TÜV
SÜD for conformity with the basic requirements of IEC
62282-5 and have been awarded the seal of approval for
product safety.
2.7 Disposal
Packaging
Packaging protected your DuoCartSwitch during shipping. All
materials are environmentally friendly and recyclable.
Please help protect our environment by disposing of
packaging properly.
Your dealer or community authorities can inform you about
proper disposal.
WARNING!
Danger of Suffocation!
Keep packaging away from children. Plastic wrapping and
cartons may cause suffocation.
Old units
Old units are still valuable! Proper disposal can yield
valuable raw materials while protecting the environment.

2. Introduction
7
The hotline can advise you about returning old units:
Headquarter Europe: North America:
+49 89 – 673 592 555 +1 240 – 328 6688
Freecall: 00800 732 762 78*
*The toll-free number via landline is available in the following countries:
Germany, Belgium, Denmark, France, Great Britain, Italy, the
Netherlands, Norway, Austria, Sweden, Switzerland and Spain.
2.8 Specification label
Input voltage of the unit: 12V / 24V DC
Operating temperature of the unit:
-20 °C up to +45 ° C / -4 °F up to +113 °F.
IP Protection class: IP 20
Serial number
Warning: Do not open the unit. Keep dry.
Use only EFOY Cartridges.
The DuoCartSwitch has undergone
voluntary testing by TÜV SÜD for
conformity with the basic requirements
of IEC 62282-5.
SFC Energy declares that the
DuoCartSwitch DCS1 conform to the
European Community’s 2004/108/EG
guidelines for electro-magnetic
compatibility (Chapter 2.5, page 6).
Proper disposal can yield raw materials
while protecting the environment
(Chapter 2.7, page 6).

4. Installation
8
3. Configuration
3.1 Standard Equipment
Standard Equipment:
1 DuoCartSwitch DCS1
2 Port-Doppler
3 Data line, Length 50.0 cm / 19.7 in, Cat5
4 User Manual
3.2 Overview
1 Data Interface (Connection for Port-Doppler)
2 Connector for EFOY Pro fuel cell
3 DuoCartSwitch connector #1
4 DuoCartSwitch connector #2
3.3 Specifications DuoCartSwitch
Dimensions (L x W x H) : 174.0 x 119.0 x 96.0 mm / 6.9 x 4.7 x 3.8 in
Weight 0.7 kg / 24.7 oz
Operating temperature: -20 °C to +45 °C / -4 °F to +113 °F
Quiescent current draw 7.5 mA
Max. leakage rate 280 mg per hour
Compatible fuel cells EFOY Pro Series
Firmware Version 9.17 / 11.04 / 17.06 and higher (from production date
September 2009).
M5, M10
Compatible fuel cartridges
M28 (with M28 adapter)
Nominal Voltage 12 V / 24 V
Switch signal GPO (General Purpose Output) at PIN1 of EFOY Pro
1 2
3
4
3
2
1

4. Installation
9
4. Installation
4.1 Installation
WARNING!
Keep the DuoCartSwitch and fuel cartridges away from
children, temperatures in excess of 50 °C / 122 °F and
direct sunlight.
For detailed information to the EFOY Pro fuel cells please
refer to the EFOY Pro user manual.
1. Make sure to install the DuoCartSwitch so that no water
can infiltrate through the data interface or the breather hole.
2. Define a position to fix the EFOY Pro, the DuoCartSwitch
and the cartridges. Control the length of the connection
hoses and the data lines.
3. Install the DuoCartSwitch and the fuel cartridge holder
with four suitable screws and dowels, if necessary, so that it
will not shake loose in case of an accident, at mobile
applications.
Indice
Lingue:
Altri manuali EFOY Interruttore