USA/CA-13
Technical data/Troubleshooting
USA/CA-14
Troubleshooting
Problem Cause Solution
No radio 1. Transmitter is 1. Program the
reception not programmed. transmitter.
2. No mains 2. Switch on the mains
voltage. supply again.
Bad radio Unsuitable receiver Change the location of
reception position. the receiver or the antenna.
Inverted sense Sense are program- Delete transmitter and
of rotation med incorrectly. program correctly.
Combio-915 JA Combio-915 RM
(venetian blind drives) (tubular motors)
Nominal voltage 120 V 120 V
Frequency 60 Hz 60 Hz
Max. 450 W 450 W
Protection class IP 54 IP 54
Permitted
ambient
temperature –20 to +80°C –20 to +80°C
Radio frequency 915 MHz frequency band
Mains cable 0,5 m with 3 m
Hirschmann plug
Motor cable 0,25 m with 0,25 m with
Hirschmann female plug plug
Dimensions in mm L 100 x B 44 x H 15 L 100 x B 44xH15
Max. number
of transmitters 16 16
USA
CA
Technical data
EC-Declaration of conformity
E C - D E C L A R A T I O N O F C O N F O R M I T Y
We hereby declare that the following mentioned product/s meet/s
the standards of the European Community.
Product designation: ProLine
xCombio-868/ -915/ -433 all versions
xVarioTec-868 /-915 all versions
xRevio-868 all versions
xAeroControl-868
xUniLogic-868/ -915
Description: Radio receiver for controlling roller shutters,
blinds and other shading systems
The conformity of the above mentioned products with the relevant
requirements is approved by the following directives and standards:
xEMC Directive 2004/108/EC
xEN 60335-1, EN 61000-6-2,
EN 61000-6-3, EN 61000-4-5
xLow Voltage Directive 2006/95/EC
xEN 61000-4-4, EN 61000-4-2
xEN 61000-4-11, EN 61000-4-5
xR&TTE-Directives 1999/5/EC
xETSI EN 301 489-3 V1.4.1
xETSI EN 300 220-3 V2.3.1
xDIN EN 60730-1 (VDE 0631 part 1);
EN 30730-1 +A1 +A2 +A11 bis A17
xDIN EN 60730-2-7 (VDE 0631 part 2-7);
EN 60730-2-7 +A1 +A11 +A12 +A13 +A14
Beuren, 29.12.2009
elero GmbH
Ulrich Seeker Antriebstechnik
– CE Officer – Linsenhofer Str. 59–63
– Representative – D-72660 Beuren