Elexa GUARDIAN GBR1 Manuale utente

GBR1
User Manual
Guardian Bridge
BY ELEXA

Page 2
Guardian Bridge Advanced User Manual
Preface
BY ELEXA
As this is the full User Manual, a working knowledge of Z-Wave automa-
tion terminology and concepts will be assumed. If you are a beginner user,
please visit www.getguardian.com for instructions. This manual will pro-
vide in-depth technical information about the Guardian Bridge, especially
in regards to its compliance to the Z-Wave standard (such as compatible
Command Classes, Association Group capabilities, special features, and
other information) that will help you maximize the utility of this product in
your system.
Preface

Page 3
Guardian Bridge Advanced User Manual
Table of Contents
BY ELEXA
Table of Contents
Preface ........................................................................................................2
Description ..................................................................................................4
Specifications..............................................................................................4
Inclusion & Exclusion...................................................................................5
Reset to Factory Default ..............................................................................6
Physical Installation ....................................................................................7
LEDs Behavior .............................................................................................8
Button Behavior ...........................................................................................9
Compatible Command Classes..................................................................10
“Configuration” Command Class Parameters ............................................12
Troubleshooting ........................................................................................13
Warranty & Support....................................................................................14

Page 4
Guardian Bridge Advanced User Manual
Specications
BY ELEXA
Specications
Technical Specications
Radio protocol Z-Wave(500 series)
LoRa
Power supply 5 VDC OR 12VDC
Working current NA
Operating temperature 0 - 40 °C
Radio frequency 908.4 MHz US (Z-Wave)
915 MHz (LoRa)
Range Up to 40m (Z-Wave) depending on environment
Up to 500m (LoRa)
Dimensions (L x W) Board: 119 x 60 mm
Update OTA
Guardian Bridge device was developed to provide the Guardian
product line compatibility with Z-Wave Network protocol.
Description

Page 5
Guardian Bridge Advanced User Manual
Inclusion & Exclusion
BY ELEXA
Inclusion (Add to System) for Z-Wave and LoRa
1. For proper inclusion, bring the Guardian Bridge to the final location where it will
be used*.
2. Follow the instructions for your Z-Wave controller to enter on inclusion mode.
3. Supply power to the Guardian Bridge to begin inclusion mode. If the Guard-
ian Bridge is already powered on, press the button 3 times quickly within 1,5 se-
conds.
4. The device will enter inclusion mode for 15 seconds.
Upon successful inclusion, the 1st LED will stop blinking and stay turned off.
Exclusion (Remove from System) for Z-Wave and LoRa
Follow the instructions for your Z-Wave Certified Controller to enter exclusion
mode. When prompted by the controller:
1. Make sure the Guardian Bridge is powered on.
2. Press the Button 3 times quickly within 1,5 seconds.
Upon successful exclusion, the 1st LED will start blinking in 500ms.
NWI - Network Wide Inclusion
This Device supports NWI - Network Wide Inclusion.
1. Follow the instructions for your Z-Wave controller to enter on Inclusion/Exclu-
sion mode.
2. Supply power to the Guardian Bridge to begin inclusion/exclusion mode. If
the Guardian Bridge is already powered on, NWI will be activated automatically if
Guardian Bridge is already out of a Z-Wave Network.
3. When Guardian Bridge is out a Z-Wave Network, and Controller enters in Exclu-
sion mode, Guardian Bridge will be removed automatically through the NWI.
Upon successful in both cases, results is the same as Inclusion/Exclusion Default
procedures.
*For non Z-Wave Plus networks, please consult the owner’s manual for your primary controller to determine the best method/location
for adding the Guardian Bridge to your Z-Wave network. A Security Enabled Z-Wave Controller must be used in order to fully utilize the
product.
Inclusion & Exclusion

Page 6
Guardian Bridge Advanced User Manual
Reset to Factory Default
BY ELEXA
Resetting the Guardian Bridge
If needed, the Guardian Bridge can be reset locally by following these steps.
Only do this if your Z-Wave controller is missing or otherwise unreachable.
Beware that resetting your device will disconnect it from the system:
1. Make sure that your Guardian Bridge is powered on.
2. Press & Hold the button for 10 seconds.
3. The 1st LED will turn on and right after that, release the Button.
The Guardian Bridge memory will be erased to factory settings excluding
all Associations. This procedure also sends a Device Reset Locally to AG01
- Lifeline notification.
4. The 1st LED will start blinking in 500ms.
Reset to Factory Default

Page 7
Guardian Bridge Advanced User Manual
Physical Installation
BY ELEXA
The Guardian Bridge can be plugged directly into a Micro USB power supply.
Include the Guardian Bridge into your Z-Wave network and make sure it can
communicate from the installation location before continuing further.
Physical Installation

Page 8
Guardian Bridge Advanced User Manual
LEDs Behavior
BY ELEXA
LED Behavior This happens when…
First LED (Z-Wave)
1st LED Blinking in 500ms Guardian Bridge isn’t in a Z-Wave Network
1st LED Turned Off Guardian Bridge is included in a Z-Wave
Network
1st LED Flash 1st LED will ash every time that a
Z-Wave transmission happens.
Second LED
(Power) LED is On Guardian Bridge is Powered On
Third LED
(Guardian RF) LED Flashes 3rd LED will ash every time that a
Guardian RF transmission happens.
LEDs Behavior

Page 9
Guardian Bridge Advanced User Manual
Button Behavior
BY ELEXA
LED Behavior This happens when…
First LED (Z-Wave)
1st LED Blinking in 500ms Guardian Bridge isn’t in a Z-Wave Network
1st LED Turned Off Guardian Bridge is included in a Z-Wave
Network
1st LED Flash 1st LED will ash every time that a
Z-Wave transmission happens.
Second LED
(Power) LED is On Guardian Bridge is Powered On
Third LED
(Guardian RF) LED Flashes 3rd LED will ash every time that a
Guardian RF transmission happens.
Action Condition Result
Push Button
3x within 1,5
seconds
Always Guardian Bridge will enter in Learn Mode
(Add/Remove from a Z-Wave Network)
Press and Hold
for 10 seconds Always
The Guardian Bridge memory will be erased to
factory settings excluding all Associations. This
procedure also sends a Device Reset Locally to
AG01 - Lifeline notication.
Association Groups (AGs)
The Guardian Bridge supports up to 5 Node IDs on AGs. Please see be-
low a description of all available Association Groups:
Association Group 01
Lifeline
This AG sends Binary Report when happens a Valve
Open/Close action.
It also supports a Device Reset Locally.
When any Guardian Leak Detector is wet, the Device
will send a Leak Notication
Association Group 02 This AG supports a Open/Close Basic Report
Association Group 03 This AG supports a Sensor Multilevel Report contain-
ing the Temperature information every 60 seconds
Button Behavior

Page 10
Guardian Bridge Advanced User Manual
Compatible Command Classes
BY ELEXA
Command Class Notes
COMMAND_CLASS_VERSION V2 (86)
Returned Value: 03 04 3D 01 01 01 00
Z-Wave Library Type: 03
(Enhanced Slave)
Protocol Version: 04 3D
Protocol Sub-Version: 01 01
Application Version: 01
Application Sub-Version: 00
COMMAND_CLASS_BASIC V1 (20) -
COMMAND_CLASS_SWITCH_BINARY V1 (25)
Binary Switch commands will open/close the valve. Reports are used
to communicate valve opening/closing
Valve Open: FF
Valve Closed: 00
COMMAND_CLASS_SENSOR_MULTILEVEL V11 (31)
The Multilevel CC is used to communicate the temperature recorded
by the Valve Controller in the Guardian system. This is only reported
to association group 3.
Returned Value: 01 XX XX
Sensor Type 01 (Temperature)
Precision/Scale/Size (Celsius) 01 (Precision = 000; Scale = 00; Size =
001)
Precision/Scale/Size (Farenheit) 01 (Precision = 000; Scale = 00; Size
= 001)
Sensor Data 00 ~ FF (-125 ~ 125 in Degrees Fahrenheit or Celsius)
COMMAND_CLASS_MULTI_CHANNEL V4 (60)
The Multi Channel Command Class is used to distinguish commands
to/from the Valve Controller endpoint (endpoint 1) and the Leak De-
tector endpoint (endpoint 2).
COMMAND_CLASS_ASSOCIATION V2 (85) Group 1
Group 1 is the “Lifeline” group, which can hold ve devices.
COMMAND_CLASS_ASSOCIATION_GRP_INFO V3 (59) -
COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
(72)
Returned Value: 02 1F 01 02 03 04
Manufacturer ID: 02 1F
Product Type: 01 02
Product ID: 03 04
COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 (5A) -
COMMAND_CLASS_POWERLEVEL V1 (73) -
COMMAND_CLASS_SUPERVISION V1 (6C) -
COMMAND_CLASS_FIRMWARE_UPDATE_MD V4 (7A) -
COMMAND_CLASS_CONFIGURATION V1 (70) See ““Conguration” Command Class Parameters”
Compatible Command Classes
Indice