Envirovent energiSava 200 Manuale utente


SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
01 Introduction
You are about to install a product that is designed to outlast
the life-cycle of the building. Once installed the unit will operate
continuously for 5 years and beyond without a major service.
Please therefore ensure that this product is treated with care
and installed properly i.e. for the life of the building. If the unit
is mishandled you might break it! This invalidates the warranty.
And remember, if you have any problems please call our
dedicated Technical Team. We are always pleased to help and
in an emergency will come out to site quickly, completely free
of charge.
Thank you for choosing EnviroVent
The fastest growing ventilation company in the UK
HOTLINE: 0345 27 27 810
Due to our policy of continuous innovation and improvement EnviroVent
reserves the right to alter products specication and appearance without
notice.
01

AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY 02
02 About The Unit
The energiSava 200 is a whole house heat
recovery unit which works by continuously
extracting stale, moisture-laden air from the
“Wet Rooms” of the apartment or a house -
the kitchen, bathroom and en-suite rooms -
and ducts this to a central unit. This extracted
air passes through a high eciency counter-
ow heat exchanger before being ducted to
the outside. Fresh air is drawn into the unit
from outside, which is warmed by the heat
exchange cell and delivered into the living,
dining and bedroom areas.
EXPLODED VIEW
Front cover
Mounting
plate
Spigot
Rear
shell
Filter & Filter plugs
Motor assembly
Heat recovery cell
Fixing rods
Bypass

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
03 Wiring Diagram
03
Commissioning -
Electrical Connections
The appliance must be earthed and a double
pole switch having a minimum contact
separation of 3.0mm must be used to
provide isolation for the unit. All wiring must
be completed by a qualied electrician. This
appliance is suitable for 230V ~ 50Hz single
phase supply fused at 3 amps.
The appliance is supplied with a 4 core mains
exible cable.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualied persons in order to
avoid a hazard.
Emergency shutdown details - Unit to be isolated
from the mains by turning it o at the isolating switch.
Fan connection-
RH conguration
shown. Reverse
for LH.

AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY 04
04 Technical Specications
Maximum Flow Rate 67 l/s (241m3/h) MAX* Protection Class IPX2
Heat Exchanger Counter Flow (Plastic) Supply Filter
Extract Filter
G3
G3
Fans EC (Electronically
Commutated DC) Spigot Ø 125mm
Electrical Supply 230V/1PH/50Hz Dimensions 571 x 646 x 335mm
Max Power Consumption 140W Weight 14kg

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
05 Installation Instructions
05
IMPORTANT
Be sure to have read and understood these
instructions before beginning the installation
process.
PRE-INSTALLATION CHECK LIST
Make sure that the unit can physically t in to
the desired location.
The energiSava®200 unit should be
situated so that access for maintenance or
replacement of parts is possible. Make the
ductwork runs as short as possible. Having
the most direct route and using as few
bends as possible will reduce air resistance
and improve the eciency of the unit.
SAFETY AND RECOMMENDATIONS
• All wiring must comply with Building
Regulations and the current I.E.E. Wiring
Regulations (BS7671) or the equivalent
standards for your country. The nal
installation should be examined and tested
by a qualied electrician.
• Precautions must be taken to avoid the
back-ow of gases into the dwelling from
the open ue of gas or other fuel-burning
appliances.
• Make sure the mains supply complies with
the rating label for voltage, frequency and
phase.
• This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning
use of the appliance in a safe way and
understand the hazards involved. Children
shall not play with the appliance. Cleaning
and user maintenance shall not be made
by children without supervision.

AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
05 Installation Instructions
06
Control Options
Frost Protection
When the cell temperature in the unit falls below
5ºC the unit automatically warms the cell with
extracted air to prevent the formation of frost.
Boost - Switch Live
The energiSava 200®comes with Switch Live
as standard. It is an automatic function, sending
the unit to boost when the bathroom or kitchen
light is on.
Summer Bypass
The summer bypass helps reduce the air
temperature coming into the dwelling during the
summer months. It is an automatic function and
operates when the supply air temperature to the
property is above 25ºC.
Intellitrac®Humidity Tracking
When the energiSava®200 unit senses a rise
in humidity, caused by increased moisture
generation such as through cooking or
showering, the extract and supply airows will
slowly begin to increase in direct proportion to
the increase in humidity.
It will then automatically track back down again
when humidity falls. This controls condensation
quietly and eciently.
Boost - Remote Control
The energiSava®200 unit also comes with a
remote control switch which can be used at any
time to send the unit to boost for 20 mins (see
page 13).
Control Options
Frost Protection
Boost Switch Live
Mechanical Summer
Bypass
Humidity Tracking
Boost - Remote Control

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
07
05 Installation Instructions
Ducting Conguration
See page 10 for duct connections to the unit/airow directions
FIRST FIX - Installing ductwork and electrical supply
1. Locate external terminations (supply and extract) in accordance with the latest addition of
the Domestic Ventilation Compliance Guide.
2. Ductwork within house Ø125mm - maximise duct size where possible. Make sure that the
ductwork is insulated in unheated spaces. Minimise exible duct.
3. Locate the mains supply within 1m of the location of unit. The position of the electrical
power supply or unit (a fused switched isolator) must not be mounted above or closer
than 1m to a cooker where it could be aected by excessive heat or moisture.
4. Make sure that there is room for the MVHR unit. The unit is designed to be mounted
horizontally on a ceiling or the underside of a ceiling slab.
5. Also make sure that there is a free space at the front of the appliance for cleaning the lter
and carrying out maintenance on the appliance.

AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
05 Installation Instructions
08
SECOND FIX - Installing the unit
1. Tape template at to ceiling. Ensure it is in
the correct orientation and that you have
left space for access.
2. Fix brackets to template in positions
indicated by using screws provided.
3. Slot unit into bracket (a) and then lift the
threaded pins up into and across the ‘J’
slots on bracket (b).
4. IMPORTANT! Ensure you have a rm
footing and the unit is fully supported until
secured in place. Place security screw
and nuts into the bracket (b) to ensure
the unit is secure.
a
b
a
b

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
09
05 Installation Instructions
SECOND FIX - Installing the unit
5. Ensure that there is enough space for the
condensate drain to be tted and ducts
to be connected.
Ensure that the slope to the drain is
maintained.
6. Prepare the drain. All MVHR units
produce condensate. The condensation
drain should be located at the lowest
point in the foam moulding as shown
overleaf. It is recommend that the drain
is prepared before the unit is assembled
to the ceiling.
Altri manuali per energiSava 200
4
Indice
Altri manuali Envirovent Sistema di riscaldamento

Envirovent
Envirovent energiSava 250 Manuale utente

Envirovent
Envirovent heatSava Manuale utente

Envirovent
Envirovent energiSava 200 Manuale utente

Envirovent
Envirovent energiSava 250 Manuale utente

Envirovent
Envirovent energiSava 200 Manuale utente

Envirovent
Envirovent energiSava 325 Guida rapida

Envirovent
Envirovent heatSava Manuale utente

Envirovent
Envirovent heatSava Manuale utente

Envirovent
Envirovent energiSava 500 Guida rapida