B1PF Actuator
3 Port Motorised Valve Actuator
Important: Keep this document
The B1PF range of actuators c/w auxiliary switch are specically
designed for use in domestic applications only.
They are not designed for use in commercial or industrial
applications such as schools, nursing homes or hotels where large
commercial pump sets are tted.
Warranty will be void If a valve is tted in any application other
than domestic.
Please note we have a full range of commercial and industrial valves
to suit every application.
CAUTION! Installation and connection
should only be carried out by a qualied person
and in accordance with wiring regulations.
Do not open the products. There are no serviceable
or adjustable parts inside. The system must be fused
to no more than 3 Amps.
Isolate mains supply before installation commences.
Isolate mains supply before attaching cable to
actuator.
Isolate mains supply before detaching cable from
actuator.
If this equipment is installed or used in a way not
specied by the manufacturer, its safety may be
impaired.
TECHNICAL SPECIFICATION
ACTUATOR MANUFACTURER MODEL SIZE & TYPE MAX. CLOSE OFF PRESSURE
B1PF
replacement
for
EPH B322P(F) 22mm Compression 1.0 Bar
EPH B328P(F) 28mm Compression 0.6 Bar
Honeywell V4073A 22mm Compression 1.0 Bar
Honeywell V4044C 28mm Compression 0.6 Bar
Horstmann 2322 22mm Compression 1.0 Bar
ACTUATOR
Motor supply voltage 230V Impedance protected motor
Rated impulse voltage 2500V Max. ambient temperature 50˚C
Power consumption 5W Protection rating IP20
LEAD SUPPLIED 1.2 metre cable. Earth Connection required.
ACTUATOR OPERATION
230V Power to open - Spring return to close.
This is not a fail safe, a no fail or a safety product.
This control is designated Type 1. AA. C in accordance with EN60730.
Type of action is multi position. Type of movement is rotary.
MANUAL OVERRIDE
Valve may be manually opened for lling or draining the system.
In normal operation, the lever must be in the Auto position
If the mains power is disconnected, the valve will automatically spring
return to the closed position (Port A)