EQK EACH7R2W Manuale utente

Thank you very much for purchasing our air conditioner. Please read this owen's manual carefully before
using your air conditioner.
Model No.: EACH7R2W
EACH9R2W
EACH12R2W
EACH18R2W
EACH24R2W
User Manual
Multi Zone Indoor User Manual

Contents
Remotecontrolleroperatinginstructions.See"remotecontroller
instructions".
Forindoorunitonly, please refer to theoutdoorunit’s USE AND
INSTALLTION INSTRUCTIONS for the outdoorunit.
Safety Instructions 1
Care and Maintenance 17
Protection 18
Energy Saving Tips 19
Troubleshooting 20
Safety Precautions 4
Preset 3
Safeguarding the Environment 3
3
Preparation before Use
Indoor Unit Installation 7
Power and Wiring 13
Installation Diagram 5
Start-up 16
Installation Instructions 5
Site Instructions 5
Suggested Tools 6
Indoor Unit 21
Outdoor Unit 21
Display Introduction 22
Identification of Parts 21

1
Safety Instructions
1. To guarantee the unit work normally, please read the manual carefully before
installation, and try to install strictly according to this manual.
2. Do not let air enter the refrigeration system or discharge refrigerant when moving the
air conditioner.
6. After installing, the consumer must operate the air conditioner correctly
according to this manual,keep a suitable storage for maintenance and moving of
the air conditioner in the future.
5. There must be an air-break switch.
4. Check the connecting cables and pipes carefully, make sure they are correct and firm
before connecting the power of the air conditioner.
3. Properly ground the air conditioner into the earth.
9. Warning: Risk of electric shock can cause injury or death: Disconnect all remote
electric power supplies before servicing .
8. A residual current device(RCD)with the rating of above 10mA shall be
incorporated in the fixed wiring according to the national rule.
10.The best length of the connecting pipe between the indoor unit and outdoor
unit is less than 7.5 meters(24.6ft). It will affect the efficiency of the air conditioner
if the distance longer than that length.
12.This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards I
nvolved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
13.The batteries in remote controller must be recycled or disposed of properly.
Disposal of Scrap Batteries --- Please discard the batteries as sorted municipal
waste at the accessible collection point.
11. This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.Children should be
supervised to ensure that they do not play with the appliance.
7. The Fuse of the unit:
T 3.15A or T 5A 250V
T 20A 250V
Model
EACH12R2W
Fuse of Indoor unit
EACH18R2W
EACH24R2W
Fuse of outdoor unit
T 3.15A or T 5A 250V
T 3.15A or T 5A 250V
T 3.15A or T 5A 250V
EACH9R2W T 15A 250V
T 15A 250VT 3.15A or T 5A 250V
EACH7R2W
T 15A 250V
T 30A 250V

2
Safety Instructions
15. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
14. If the appliance is fixed wiring, the appliance must be fitted with means for
disconnection from the supply mains having a contact separation in all poles
that provide full disconnection under overvoltage category III conditions, and
these means must be incorporated in the fixed wiring in accordance with the
wiring rules.
18.The appliance shall not be installed in the laundry.
16.The appliance shall be installed in accordance with local electrical safety
regulations and National Electrical Codes(NEC).
17.The air conditioner must be installed by professional or qualified persons.
20.Regarding to maintenance, please refer to section “Care and Maintenance”.
19.Regarding to installation, please refer to section “Installation instructions”.
THANK YOU
Congratulations on your purchase and welcome to the Family.
Your new Air Conditioner combines high-efficiency operation with portable convenience.
By following the operating and care instructions in this manual, your air conditioner will
provide you with many years of reliable service.
Please visit our website
www.eqkhvac.com
For any questions or Technical Support,
please contact us by mail info@geektechnology.com or by phone 1-888-493-0305.

Preparation before Use
3
The air conditioner has an Auto-Restart function.
Each time after the remote control is replaced with new batteries or is energized, auto presetting
heat pump.If the air conditioner you purchased is a Cooling Only one, heat pump remote controller can also be
used.
remote control
Remote Control Presetting
Before using the air conditioner, be sure to check and preset the following.
Auto Restart Presetting
Hold down any button on remote control to activate the back light. It automatically shuts off 10 seconds
later.
Note: Back-light is an optional function.
Back-light Function (optional)of Remote Control
This appliance is made of recyclable or re-usable material. Scrapping must be carried out in
compliance with local waste disposal regulations. Before scrapping it, make sure to cut off the
mains cord so that the appliance cannot be re-used.
For more detailed information on handling and recycling this product, contact your local authorities
who deal with the separate collection of rubbish or the shop where you bought the appliance.
SCRAPPING OF APPLIANCE
This marking indicates that this product should not be disposed
with other household wastes throughout the North America. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote
the sustainable reuse of material resources. To return your
used device, please use the return and collection systems or
contact the retailer where the product was purchased.
They can take this product for environmental safe recycling.
Note
Preset
Safeguarding the environment
When charging refrigerant into the system, make sure to charge in liquid state, if
the refrigerant of the appliance is R410A.Otherwise, chemical composition of
refrigerant (R410A) inside the system may change and thus affect performance
of the air conditioner.
According to the character of
pressure of the tube is very high, so be sure to be careful when you install and
repair the appliance.
refrigerant (R410A,the value of GWP is 2088), the
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
The air conditioner must be installed by trained, qualified installers
and service mechanics.
The temperature of refrigerant circuit will be high, please keep the
interconnection cable away from the copper tube.

Safety Precautions
Symbols in this Use and Care Manual are interpreted as shown below.
Be sure not to do.
Pay attention to such a situation.
Grounding is essential.
Warning: Incorrect handling could
cause a serious hazard, such as death,
serious injury, etc.
4
Do not use the power supply circuit
breaker or pull off the plug to turn it off
during operation. This may cause a fire
due to spark, etc.
Keep the power supply circuit breaker
or plug from dirt. Connect the power
supply cord to it firmly and correctly,
lest an electric shock or a fire break out
due to insufficient contact.
Use correct power supply in
accordance with the rating plate
requirement. Otherwise, serious
faults or hazard may occur or a
fire maybe break out.
Do not knit, pull or press the power supply
cord, lest the power supply cord be broken.
An electric shock or fire is probably caused
by a broken power supply cord.
Never insert a stick or similar obstacle
to the unit. Since the fan rotates at high
speed, this may cause an injury.
Do not repair the appliance by yourself.
If this is done incorrectly, it may cause an
electric shock, etc.
Turn off the appliance by remote control
firstly before cutting off power supply if
malfunction occurs.
It is harmful to your health if the cool air
reaches you for a long time. It is advisable
to let the air flow be deflected to all the room.
Prevent the air flow from reaching the gas
burners and stove.
Do not touch the operation buttons
when your hands are wet.
Do not put any objects on the outdoor
unit.
It is the user's responsibility to make the
appliance be grounded according to
local codes or ordinances by a licenced
technician.
OFF OFF
ON
ON
ON/OFF
MODE FAN
SWINGSLEEPSUPER
SMART IFEELDIMMER
TIMER ON TIMER OFFCLOCK
ON
OFF
ON
OFF

5
Installation Instructions
Installation must be performed in accordance with the national wiring standards by authorized personnel only.
Above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased.
Distance from ceiling
Distance from wall
should be over 50mm/2in
Distance from the wall
should be over
200 mm/7.9in
should be over 50mm/2in
Distance from floor
over 2.4m/8ft. should be
Distance from the obstacle
should be over 3.0m/10ft.
Indoor unit A
Installation diagram
Site Instructions
Site for Installing Indoor Unit
Installation of outdoor unit refers to the outdoor unit installation manual.
1. Where there is no obstacle near the air outlet and air can be
easily blown to every corner.
2. Where piping and wall hole can be easily arranged.
3. Keep the required space from the unit to the ceiling and wall
according to the installation diagram on previous page.
4. Where the air filter can be easily removed.
5. Keep the unit and remote controller 1m(3.28ft) or more apart
from television, radio etc.
6. Keep as far as possible from fluorescent lamps.
7. Do not put anything near the air inlet to obstruct it from air
absorption.
8. Install on a wall that is strong enough to bear the weight of t
he unit.
9. Install in a place that will not increase operation noise and
vibration.
10. Keep away from direct sunlight and heating sources. Do not place
flammable materials or combustion apparatuses on top of the unit.
Outdoor unit
Indoor unit
Pipe length is
20 meters
(65.4ft) Max.
be less than 10m (32.8ft)
Height should
Indoor unit is higher than outdoor unit

6
Installation Instructions
Suggested Tools
In order to install your air-conditioner more conveniently and safely, you might use
those special tools listed below.
Standard Wrench
Screw Driver
Hex Keys or Allen Wrenches
Adjustable/Crescent Wrench
Torque wrench
Drill & Drill Bits
Manifold and Gauges
Vacuum Pump
Clamp on Amp Meter
Level
Work Gloves
Safety Glasses
Pipe Cutter
Refrigerant Scale
R410A Flaring Tool
Micron Gauge
Hole Saw

7
Installation Instructions
Indoor unit installation
.Keep the mounting plate horizontal with a horizontal level or dropping line.
Mark the center of the indoor unit on mounting plate for future reference.
Tapping mounting plate to the wall with a minimum of five screws, evenly spaced to properly support
indoor unit weight.
1. Installing the Mounting Plate
MOUNTING BRACKET DIAGRAMS AND DIMENSIONS (Recommended)
Decide an installing location for the mounting plate according to the indoor unit location and piping
direction.
Mounting plate
Tapping screw
Note: The shape of your mounting plate may be different from the one above, but the installation method is similar.
Note: it is recommended to install screw anchors for sheet rock, concrete block, brick and such type of wall.
Note: the center of the mounting bracket may be not the center of the indoor unit.
Note: As the above figure shown, the six holes matched with tapping screw on the mounting plate must be used to
fix the mounting plate, the others are prepared.
For EACH7R2W, EACH9R2W, EACH12R2W Model, WIDTH:592mm/23.3in
200mm/7.9in or more to ceiling
50mm/2in
or more to wall50mm/2in
or more to wall
Indoor unit outline
FOR the Ordinary Mounting Plate
Pipe hole

8
Installation Instructions
MOUNTING BRACKET DIAGRAMS AND DIMENSIONS (Recommended)
For EACH18R2W, EACH24R2W Model, WIDTH: 629mm/24.8in
200mm/7.9in or more to ceiling
50mm/2in
or more to wall50mm/2in
or more to wall
Indoor unit outline
Pipe hole
FOR the Ordinary Mounting Plate
Questo manuale è adatto per i seguenti modelli
4
Indice
Lingue:
Altri manuali EQK Unità di trattamento dell'aria