Escea EW5000 Istruzioni per il montaggio

Installation Instructions
and User Guide
EW5000
ESCEA FIREPLACE KITCHEN
630187_10

WARRANTY REPAIR AND ANNUAL SERVICING
Please contact Escea if you require warranty work. Warranty repair work must be carried out by a
recognised Escea woodfire installer. It is recommended that recognised Escea Wood Fire Installers are
also used to carry out annual servicing requirements (particularly during the warranty period). For contact
details of recognised Escea Wood Fire Technicians in your area, or for replacement parts, please contact
the retailer from whom the appliance was purchased from, or visit our website.
All installation work must comply to AS/NZS 2918 Domestic solid fuel burning appliances- Installation
AND these installation instructions. Any work undertaken that does not comply to AS/NZS 2918 AND
these installation instructions will not qualify for the Escea warranty. Escea will not be accountable for any
unsafe installation that does not comply to AS/NZS 2918.
Please contact your local council for updates to AS/NZS 2918 or additional restrictions. The installation
must comply to any additional requirements to qualify for the Escea Warranty.
Manufactured by: Escea Ltd, PO Box 5277 Dunedin NZ, Ph: +64 3 478 8220
For contact details of your local Escea distributor or dealer, please visit www.escea.com,
From Australia, please visit www.escea.com.au, call AU: 1800 460 832 or WA: 1800 730 140, or email

CONTENTS
A Saftey Information 4
B Product Details 6
B1 Product Description
B2 Installation Scenarios
B3 Product Dimensions
C External Clearances to Combustible Surfaces 10
D Concrete/ Block Structure Installation 11
D1 Minimum Requirements of Concrete/ Block Structure
D2 Sealing Requirements
D3 Concrete/ Block Structure Flue System Installation
E Timber/ Combustible Structure Installation 15
E1 Minimum Requirements of the Timber/ Combustible Structure
E2 Sealing Requirement
E3 Autoclaved Aerated Concrete (AAC) Heat Cell Assembly
E4 Timber/ Combustible Structure Flue System Installation
E5 Heat Cell Construction Recommendations
F Assembling and Installing the Fireplace 22
F1 Placement of Interior Parts
F2 Fitting the Fascia
G Operation Guide 24
G1 Fuel Selection
G2 Starting the Fire
G3 Loading the Fire
G4 Extinguishing the Fire
H Maintenance 26
H1 Cleaning the Fascia
H2 Chimney Maintenance
H3 Recommended Refurbishment Products
I General Warranty Terms and Conditions 27

4630187_10 EW5000 InstallatIon Manual
AA SAFETY INFORMATION
NOTICE
DO NOT DISCARD THIS MANUAL
IMPORTANT OPERATING AND MAINTENANCE
INSTRUCTIONS INCLUDED.
READ, UNDERSTAND AND FOLLOW THESE
INSTRUCTIONS FOR SAFE INSTALLATION AND
OPERATION.
LEAVE THIS MANUAL WITH PARTY
RESPONSIBLE FOR USE AND OPERATION.
WARNING
IF THE INFORMATION IN THESE
INSTRUCTIONS IS NOT FOLLOWED EXACTLY,
A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
IMPROPER INSTALLATION, ADJUSTMENT,
AERATION, SERVICE OR MAINTENANCE
CAN CAUSE INJURY OR PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH. PLEASE READ
ENTIRE MANUAL BEFORE YOU INSTALL AND
USE YOUR APPLIANCE.
THIS APPLIANCE IS NOT TO BE USED BY
PERSONS INCLUDING CHILDREN WITH
REDUCED PHYSICAL, SENSORY, OR MENTAL
CAPABILITIES, OR LACK OF EXPERIENCE AND
KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING
USE OF THE APPLIANCE BY A PERSON
RESPONSIBLE FOR THEIR SAFETY.
WARNING: THIS APPLIANCE AND FLUE
SYSTEM MUST BE INSTALLED IN ACCORDANCE
WITH AS/NZS 2918 AND THE APPROPRIATE
REQUIREMENTS OF ANY RELEVANT LOCAL/
NATIONAL BUILDING CODES.
CAUTION: THIS APPLIANCE SHOULD BE
MAINTAINED AND OPERATED AT ALL TIMES IN
ACCORDANCE WITH THESE INSTRUCTIONS:
ͳThe appliance should be allowed to cool before servicing.
ͳDo not operate without fully assembling all components.
ͳRisk of cuts and abrasions. Wear protective gloves and
safety glasses during installation. Sheet metal edges may
be sharp.
ͳDo not operate appliance before reading and
understanding operating instructions. Failure to operate
appliance according to operating instructions could
cause fire or injury.
CAUTION: MIXING OF APPLIANCE OR FLUE
SYSTEM COMPONENTS FROM DIFFERENT
SOURCES OR MODIFYING THE DIMENSIONAL
SPECIFICATION OF COMPONENTS MAY RESULT
IN HAZARDOUS CONDITIONS. WHERE SUCH
ACTION IS CONSIDERED, THE DISTRIBUTOR:
ESCEA LTD SHOULD BE CONSULTED AT THE
FIRST INSTANCE.

55
A
ͳThis appliance can be very hot when burning.
ͳCombustible materials such as firewood, wet
clothing, etc. placed too close can catch fire
ͳYoung children and elderly people should be
carefully supervised when they are in the same
room as the appliance. Toddlers, young children
and others may be susceptible to accidental
contact burns. A physical barrier is recommended
if there are at risk individuals present. To
restrict access to an appliance or stove, install an
adjustable safety gate to keep toddlers, young
children and other at risk individuals out of
the room and away from hot surfaces.Children
and pets must be prevented from touching the
appliance when it is hot.
ͳClothing or other flammable material should not
be placed on or near the appliance.
ͳDue to high temperatures, the appliance should
be located out of trac and away from furniture.
ͳEnsure you have incorporated adequate safety
measure to protect infants/toddlers from
touching hot surfaces.
ͳKeep the packaging material out of reach of
children and dispose of the material in a safe
manner. As with all plastic bags, these are not
toys and should be kept away from children and
infants.
CAUTION: THE USE OF SOME TYPES OF
PRESERVATIVETREATED WOOD AS FUEL
CAN BE HAZARDOUS.
ͳDo not start a fire with chemicals or fluids such
as gasoline, engine oil, etc.
ͳDo not burn treated wood, coal, charcoal,
coloured paper, cardboard, solvents or garbage.
ͳDo not let the appliance become hot enough for
any part to glow red.
ͳDo not overload or over fire the appliance.
ͳAshes must be disposed in a metal container
with a tight lid and placed on a non-combustible
surface well away from the home or structure
until completely cool.
ͳThe appliance must be installed using only
the building materials as approved by the
manufacturer.

6630187_10 EW5000 InstallatIon Manual
BB PRODUCT DETAILS
B1 Product Description
The Escea EW5000 is an outdoor wood burning cooking fire. The appliance is designed to burn
wood and charcoal only with the ability to transform from a cooking appliance into a fireplace for
entertainment.
The appliance can be installed into a variety of scenarios. Please note that there are dierent flue
systems to be specified for dierent install scenarios.
The serial number can be found in the lower left of the fire underneath the recepticle for the fascia
hooks. To access this the fascia must be removed as detailed in section F2 of this manual.
Always check with your local city council for additional restrictions prior to installation. Consider the
topography of the land and the prevailing wind to ensure optimal performance before installation.
Care also needs to be taken to ensure your fireplace will not cause any nuisance to your neighbours
from smoke, ash, or smells.
B2 Installation Scenarios
Concrete/ Masonry Cavity
The EW5000 can be installed into a fully non-combustible cavity on all surfaces (e.g. top/bottom/
sides/back) surrounding the fireplace. Example materials that can be used include: solid concrete,
concrete/masonry blocks, bricks, or Autoclaved Aerated Concrete (AAC) blocks/panels. This install
scenario must be free-standing and cannot be in contact with any combustible materials. The cavity
must not be connected to the envelope of a building. Please refer to section C for more details.
This scenario must be supplied with the EW Concrete Cavity Flue Kit.
The appliance can be installed with an optional fascia or frameless for this install scenario.

77
B
Timber/ Combustible Cavity
The EW5000 can also be installed within a free-standing timber/combustible cavity. The cavity
structure must be freestanding and must not be connected to the envelope of a building. However,
the cavity can penetrate through a combustible roof structure. The roof structure may be attached
to a building.
For this scenario, the appliance must be enclosed within an Autoclaved Aerated Concrete (AAC)
heat cell with a minimum thickness of 75mm thick panels having a thermal resistance/ R-value of no
less than 0.59m2 K/W. Additionally, the appliance must be installed with the EW Heat Cell Dropbox.
This scenario must be supplied with the EW5000 Timber Cavity Flue Kit.
The appliance must be frameless for this install scenario as the optional fascia is not compatible with
this installation type.
Kitset Enclosure
If you do not have a suitable structure to build you outdoor fire into, Escea can provide, as an
accessory, a ready-to-be-assembled steel frame skeleton and fastenings. This free-standing kitset
also provides the option of a fascia accessory or frameless install.

8630187_10 EW5000 InstallatIon Manual
8
B
892mm
901mm
134mm
996mm
548mm
Flue:
250mm OD
884mm Opening Width
479 mm Opening Height
426mm
122mm
377mm
504mm
758mm
64mm
EW5000 Specifications (No Fascia)
Appliance Dimensions(mm): 996W x 758H x 548D
Appliance Weight(kg): 90.3kg
Concrete or Concrete Block Structure
Minimum Internal Cavity Dimensions (mm): 1077W x 835D
Timber or Combustible Structure
Minimum AAC Heat Cell Dimensions (mm): 1200W x 950H x 735D
Minimum Cavity Dimensions (mm): 1270W x 1550H x 770D
For Installations Without Fascia:
B3 Product Dimensions

99
B
For Installations with Fascia:
EW5000 Specifications (With Fascia)
Appliance Dimensions(mm): 1292W x 758H x 551 D
Appliance Weight(kg): 99.8kg
Concrete or Concrete Block Structure
Minimum Internal Cavity Dimensions (mm): 1077W x 835D
892mm
901mm
134mm
996mm
Flue:
250mm OD
50mm
1292mm Fascia Width
644mm Fascia Height
426mm
122mm
377mm
504mm
758mm

10
C
630187_10 EW5000 InstallatIon Manual
A EXTERNAL CLEARANCES
Any combustibles in front of the fireplace need to be no less than 2000mm from the opening of the
fire and 650mm to each side. Any heat sensitive roofing/ceiling material above the fireplace must be
no less than 1400mm from the appliance opening.
Also check with your city council (municipal authority) for local restrictions.
Note: The cavity structure must comply with the relevant section “D1 Minimum Requirements of
Concrete | Concrete Blosk Structure” on page 11 or section “ E1 Minimum Requirements of the
Timber | Combustable Structure” on page 15, depending on the installation method of choice. For
flue external clearances, refer to AS/NZS2918:2001.
Appliance opening
Appliance opening
Heat-sensitive material sidewall
650mm min
1400mm min
2000mm min
Any heat-sensitive material
Any heat sensitive roofing/ ceiling material
Floor must be non-combustible
SIDE VIEW
TOP VIEW
Altri manuali per EW5000
3
Indice
Altri manuali Escea Camino da interno

Escea
Escea EF5000 Manuale utente

Escea
Escea DL850 Manuale utente

Escea
Escea DS 1900 Istruzioni di installazione e manutenzione

Escea
Escea ST900 Manuale utente

Escea
Escea DX1000 Manuale utente

Escea
Escea EK950 Manuale utente

Escea
Escea DS Series Manuale utente

Escea
Escea ST900 Manuale utente

Escea
Escea EF5000 - AUS Manuale utente

Escea
Escea EF5000 - AUS Manuale utente

Escea
Escea SMART HEAT Manuale utente

Escea
Escea IB850 Manuale utente

Escea
Escea IB850 Manuale utente

Escea
Escea IB850 Manuale utente

Escea
Escea IB600 Manuale utente

Escea
Escea ST900 Manuale utente

Escea
Escea ST900 Manuale utente

Escea
Escea FS730 Manuale utente

Escea
Escea KS1150 Peninsula 400 Guida rapida

Escea
Escea EK950 Guida