ETAS ES1310.1 Manuale utente

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

ES1310.1
D/A Board
User’s Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ES1310.1 D/A Board2
Copyright
The data in this document may not be altered or amended without special
notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in
relation to this document. The software presented herein is provided on the
basis of a general license agreement or a single license. Using and copying is
only allowed in concurrence with the specifications stipulated in the contract.
Under no circumstances may any part of this document be copied, repro-
duced, transmitted, stored in a retrieval system or translated into another lan-
guage without the express written permission of ETAS GmbH.
© Copyright 2007 ETAS GmbH, Stuttgart
The names and designations used in this document are trademarks or brands
belonging to the respective owners.
Document QH131001 R1.0.5 EN TTN F 00K 102 868
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents 3
Contents
1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 Software Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5 Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1.1 Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1.2 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1.3 Board ID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.2 Hardware Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3 Addressing the D/A Converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.4 Offset for Data Transfer, Board ID and Reset . . . . . . . . . . . . . . . . . . . . . . 11
2.5 Operating Multiple ES1310.1 D/A Boards . . . . . . . . . . . . . . . . . . . . . . . . 12
2.6 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3ETAS Contact Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents4
List of Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Introduction 5
1 Introduction
This section contains information about the basic features and applications of
the ES1310.1 D/A Board.
1.1 Features
The ES1310.1 D/A Board has eight D/A converters and a VMEbus interface.
The board has the following features:
• 8 analog outputs
• dc decoupling of the analog outputs from the VMEbus
• common ground of the analog outputs
• Lemo connector for EMC-proof connection to external analog measur-
ing systems
• extended temperature range for use in vehicles
• cable with conversion from Lemo to BNC connectors is part of the
delivery package
The following figure shows the front panel of the ES1310.1 D/A Board.
Note
Some components of the ES1310.1 D/A Board may be damaged or
destroyed by electrostatic discharges. Please keep the D/A Board in its stor-
age package until it is installed.
The D/A Board should only be taken from its package, configured and
installed at a work place that is protected against static discharge.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Introduction6
Fig. 1-1 Front Panel of the ES1310.1 D/A Board
1.2 Applications
The ES1310.1 D/A Board is used for the analog output of data, e.g. for control
and simulation tasks. The data to be issued is transferred from the VMEbus,
converted on the ES1310.1 D/A Board and then output as analog data.
ES1310.1
1
2
3
4
5
6
7
8
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Introduction 7
1.3 Block Diagram
The following figure shows you a block diagram of the ES1310.1 D/A Board.
Fig. 1-2 Block Diagram
On the right you can see the VMEbus and how the signals are routed via the
VME interface to the control logic or to the D/A converters after dc decoupling.
On the left, the signals are converted in the D/A converters DAC 1 and DAC 2
and are made available via eight analog outputs.
1.4 Software Support
In one VME bus system, multiple cards of this type can be used. ASCET-SD,
equipped with Target Integration Package Experimental (TIPExp), and INCA
support up to three ES1310.1 cards.
1.5 Placement
The ES1310.1 cards have to be inserted to the right of the bus master card.
Note
The ES1310.1 card is not multi-master capable. This means that a given card
can only be accessed by either the application or the simulation node.
Hence, the simultaneous use of one card by INCA (measurement) and
ASCET-SD (RTIO/simulation) is impossible.
12-Bit D/A
Converter
Overvoltage
Protection
Overvoltage
Protection
Overvoltage
Protection
Overvoltage
Protection
4:1 MUX
12-Bit D/A
Converter
Overvoltage
Protection
Overvoltage
Protection
Overvoltage
Protection
Overvoltage
Protection
4:1 MUX
Control Unit
Slave
VMEbus Interface
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Introduction8
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Hardware 9
2 Hardware
This section contains a detailed description of the functions, information on
the hardware configuration and the connectors and the technical data of the
ES1310.1 D/A Board.
2.1 Functional Description
This section provides you with a detailed overview of the features of the
ES1310.1 D/A Board. It contains information on the following aspects:
• connectors
• outputs
• board ID and status
2.1.1 Connectors
The eight Lemo connectors on the front panel are designed as sockets and are
used to issue the output signals.
The middle pin routes the output signal, the ground is on the connector hous-
ing.
Fig. 2-1 Lemo Connector
2.1.2 Outputs
All eight analog outputs have a common ground and are dc decoupled from
the VMEbus ground. The insulation voltage is 500 V.
2.1.3 Board ID
The board has an ID which is used to identify the type of board in the VMEbus
system. The ID can be queried under the offset 0x20. The ID is 0xA5.
2.2 Hardware Configuration
This section describes the base address configuration of the board.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Indice
Altri manuali ETAS Sistema I/O
Manuali Sistema I/O popolari di altre marche

WAGO
WAGO 750-344 Manuale utente

Teknim
Teknim TWM-1887 Manuale di istruzioni

Intelligent Appliance
Intelligent Appliance IA-2662-E Manuale utente

BERGHOF
BERGHOF ECC DIO 16/16 Manuale di istruzioni

Advantech
Advantech PCM-27J3AU Manuale di installazione e funzionamento

Festo
Festo CP-E08-M12-CL Manuale utente