ETIC 1400 Manuale utente

XSLAN
SHDSL switch
_________________
User’s guide
Document reference : 9014709-02
_________________

The XSLAN SHDSL switch is manufactured by
ETIC TELECOM
13 Chemin du vieux chêne
38240 MEYLAN
FRANCE
TEL : + 33 4-76-04-20-00
FAX : + 33 4-76-04-20-01
web : www.etictelecom.com
Hotline
TEL : + 33 4-76-04-20-05
FAX : + 33 4-76-04-20-01

CONTENT
XSLAN SHDSL switch User’s guide ref 9014709-02 Page 3
OVERVIEW
1PRODUCTS IDENTIFICATION...........................................................................6
2PRODUCT OVERVIEW.......................................................................................7
2.1 Function..................................................................................................7
2.2 Data rate versus distance.....................................................................7
2.3 Ethernet ports........................................................................................8
2.4 VLAN.......................................................................................................8
2.5 Quality of service...................................................................................8
2.6 Serial gateway........................................................................................8
2.7 Diagnostic functions.............................................................................8
2.8 Html or DIP switches configuration....................................................8
3DATA-SHEET......................................................................................................9
INSTALLATION
1PRODUCT DESCRIPTION...............................................................................11
1.1 Leds.......................................................................................................12
1.2 Connectors...........................................................................................13
1.3 DIP switches and push-button...........................................................15
2VENTILATION...................................................................................................16
3SUPPLY VOLTAGE..........................................................................................16
4FUSE.................................................................................................................16
5ETHERNET PORTS..........................................................................................16
6RS232 (XSLAN—1220, 1230, 2220 AND -2230) .............................................17
7RS485 (XSLAN-1230 OR -2230)......................................................................17
8SHDSL LINE.....................................................................................................18
9INPUT AND OUTPUT.......................................................................................20
../..

CONTENT
Page 4 User’s guide ref 9014709-02 XSLAN SHDSL switch
DIP SWITCHES CONFIGURATION
1OVERVIEW.......................................................................................................21
2ONE TWISTED PAIR SHDSL LINE SET UP....................................................21
3TWO TWISTED PAIRS SHDSL LINE SET UP.................................................23
4TESTING THE SHDSL CONNECTION AND ADJUSTING THE DATA RATE24
HTML CONFIGURATION
1SET UP STEPS.................................................................................................25
2ENABLING HTML CONFIGURATION .............................................................26
3CONNECTING A PC TO THE XSLAN FOR CONFIGURATION.....................26
3.1 Overview...............................................................................................26
3.2 First configuration...............................................................................27
3.3 Modifying the configuration from the LAN........................................28
4REBOOTING THE XSLAN AFTER PARAMETERS CHANGES.....................28
5RECOVERING THE FACTORY LAN IP ADDRESS ........................................28
6RECOVERING THE FACTORY CONFIGURATION.......................................29
7RESTRICTING ACCESS TO THE ADMINISTRATION SERVER....................29
8RECOVERING A FREE ACCESS TO THE ADMINISTRATION SERVER......29
9ASSIGNING AN IP ADDRESS TO THE LAN INTERFACE.............................30
10 IP ROUTING AND BROADCAST FILTERING................................................30
11 ONE TWISTED PAIR SHDSL CONNECTION SET UP....................................33
11.1 Set up....................................................................................................33
11.2 Testing the SHDSL connection and adjusting the data rate...........34
12 TWO WISTED PAIRS UP SHDSL CONNECTION SET UP.............................35
12.1 SHDSL port set up...............................................................................35
12.2 Testing the SHDSL connection and adjusting the data rate...........36
../..

CONTENT
XSLAN SHDSL switch User’s guide ref 9014709-02 Page 5
… HTML CONFIGURATION
13 VLAN SET UP...................................................................................................37
13.1 Overview...............................................................................................37
13.2 VLAN set up .........................................................................................39
14 QUALITY OF SERVICE (QOS) SET UP..........................................................40
14.1 DiffServ benefits & overview..............................................................40
14.2 QoS set up............................................................................................41
15 SNMP SET UP..................................................................................................43
16 SERIAL GATEWAY SET UP............................................................................44
16.1 Modbus gateway..................................................................................45
16.2 RAW TCP gateway...............................................................................50
16.3 RAW UDP gateway ..............................................................................53
16.4 Multicast gateway................................................................................55
16.5 Unitelway gateway...............................................................................57
17 DIAGNOSTIC MENU ........................................................................................58
Appendix 1 : Data rate versus distance and cable quality
Appendix 2 : Html server description

INSTALLATION
Switch Shdsl XSLAN Notice d’utilisation ref 9014309-01 page 6
1 Products identification
XSLAN SHDSL switch 1400 1220 1230 2400 2220 2230
SHDSL ports 1 1 1 2 2 2
Maximum data rate (Mb/s) 2.3 2.3 2.3 4.6 4.6 4.6
10-100 Mb/s Ethernet ports 4 2 2 4 2 2
RS232 0 1 2 0 1 2
RS485 0 1 0 0 1 0
Basic IP routing feature Yes Yes Yes Yes Yes Yes
VLAN Yes Yes Yes Yes Yes Yes
Quality of service Yes Yes Yes Yes Yes Yes
Gateway
(Raw, telnet, modbus,
unitelway)
0 2 2 0 2 2
Line cable * 1 1 1 2 2 2
Χ The product is delivered with Cable ref. CAB614 for
connection to the line (Qty 1 or 2)

INSTALLATION
2 Product overview
2.1 Function
The XSLAN shdsl switch enables to extend an Ethernet network over
kilometers using one or two simple voice-grade twisted pairs (telephone
lines).
The XSLAN-1400 or 1220 or 1230 come with one SHDSL interface; they
can be connected to a one twisted pair line.
They feature up to 2.3 Mb/s.
One pair operation
up to 2.3 Mb/s
XSLAN-1400
XSLAN-1220
XSLAN-1230
The XSLAN-2400 or 2220 or 2230 come with two SHDSL interfaces; they
can be connected to a two twisted pair line.
They feature up to 2.3 Mb/s.
Two pairs operation
up to 4.6 Mb/s
XSLAN-2400
XSLAN-2220
XSLAN-2230
2.2 Data rate versus distance
Each interface features an adaptive data rate from 128 Kb/s up to 2.3
Mb/s.
The data rate is a function of the cable quality and the distance with the
next SHDSL switch. For instance, the maximum distance between 2
switches through a line is 13 Km (8 miles) with a 0.9 mm wire diameter
cable.
The table in appendix 1 gives the data rate which can be expected over a
line versus the length of the line.
XSLAN SHDSL switch User’s guide ref 9014709-02 Page 7

INSTALLATION
Page 8 User’s guide ref 9014709-02 XSLAN SHDSL switch
2.3 Ethernet ports
The XSLAN provides 2 or 4 Ethernet RJ45 interfaces (depending on the
product reference).
2.4 VLANs
The XSLAN features VLAN per port :
Each Ethernet port can be assigned to a particular VLAN. A device
connected to an Ethernet port belonging to a particular VLAN can
communicate only with devices connected to Ethernet ports belonging to
the same one.
2.5 Quality of service
The product provides “DiffServ” quality of service functionality to give
transmission priority to critical applications.
Devices TCP ports and IP addresses are classified in 4 priority classes.
A minimum and a maximum bandwidth is allocated to each class.
2.6 Serial gateway
The XSLAN –1220, -1230, -2220 or –2230 feature a 2 ports serial
gateway.
The gateway features raw TCP client and server, raw UDP, modbus
client and server, telnet and multicast.
2.7 Diagnostic functions
The XSLAN html server provides diagnostic pages giving the guarantee
the transmission quality is what it has to be.
2.8 Html or DIP switches configuration
The XSLAN can be configured either with an html browser if advanced
functions are necessary (QoS, RS gateway, diagnostic …).
It can be configured with a few DIP switches for simple unmanaged
applications.

INSTALLATION
XSLAN SHDSL switch User’s guide ref 9014709-02 Page 9
3 Data-sheet
Dimensions 137 x 48 x 116 mm (h, l, d)
C.E.M EN50082-2
Electrical safety EN 60950
Lightning EN61000-4 et –5
Supply voltage XSLAN-1400 or –2400 or –1230 or –2230 : 9 to 60 VDC
XSLAN-1220 –2220 : 9 to 30 VDC
Consumption 4W
Operating T° -20°/ + 60°C non condensing
SHDSL ITU-T G.991.2, 802.3ah : 2BaseTL (EFM)
Data rate : 128 kb/s to 2.3 Mb/s with 2 wires
Latency : 4 ms
Ethernet 10/100 Mb/s Half / Full duplex Auto MDI/MDIX
Switch Store and forward – 1024 MAC @
IP Routing Static routes
RIP V2
QoS DiffServ compliant with RFC 2474, 2475, 2597, 2598
4 priority levels (premium, gold, silver, bronze)
SNMP SNMP V2 – MIBII and traps
VLAN Per port
RS232-RS485 1200 to 115200 kb/s parity E/O/N
Raw TCP client and server
Raw UDP
Multicast
Modbus client and server
Unitelway
Telnet
Logs 300 events (date & time)
Configuration Managed mode : HTML browser
Unmanaged mode : DIP switches

Questo manuale è adatto per i seguenti modelli
5
Indice
Altri manuali ETIC Router di rete

ETIC
ETIC IPL-3G-G-1400 Manuale utente

ETIC
ETIC IPL-3G Manuale utente

ETIC
ETIC IPL-E Manuale utente

ETIC
ETIC IPL-M156 Manuale utente

ETIC
ETIC IPL-G12 Manuale utente

ETIC
ETIC IPL-CW-2 Series Manuale utente

ETIC
ETIC RAS-E Manuale utente

ETIC
ETIC IPL-DAC Manuale utente

ETIC
ETIC IPL-I1128 Manuale utente

ETIC
ETIC IPL-E-2 Series Manuale utente
Manuali Router di rete popolari di altre marche

NETGEAR
NETGEAR FS526T - Switch Manuale utente

Korenix
Korenix JetNet 5710G Series Manuale utente

Automated Logic
Automated Logic ZN551 Manuale del proprietario

Cisco
Cisco ASR 1000 Series Manuale dell'operatore

EnGenius
EnGenius ESR-9710 Manuale utente

Cisco
Cisco 805 Series Istruzioni operative e di sicurezza