EvoJet Jetronic-BOX HV Manuale utente

Jetronic-BOX HV[0288]
R/C Controller – Doorsequencer
with ir Failsave
© 2013 evoJet GmbH ● m Parir 4 ● D-52379 Langerwehe/Germany ● www.evojet.de

Jetronic-BOX HV Instructions 2.1
Contents
Introduction .........................................................................................................................3
Schematic Overview 'Doorsequencer'...............................................................................4
Factory Setting 'Doorsequencer'.......................................................................................5
Jetronic Display EDT (Engine Data Terminal)...................................................................6
JETRONIC-BOX – Setup......................................................................................................7
1:BOX-SETUP Menu.............................................................................................................8
2:RC-CONTROL Menu........................................................................................................11
3/4/5: RC-3/4/5-CONTROL Menu.......................................................................................14
6:TEST-DEVICES Menu ....................................................................................................17
CE - Konformitätserklärung / Conformity Declaration / Déclaration de conformitè ..22
2

Jetronic-BOX HV Instructions 2.1
Introduction
The Jetronic-BOX HV is a universal R/C controller for use in medium-sized and large model
aircraft Two R/C inputs can be programmed to control up to four R/C outputs, for example to
implement a landing gear with door control or a cockpit with open/close and lock functions, where
even an R/C transmitter with microprocessor control is not sufficient Since such model functions
are often realised using pneumatic systems with an air tank and a pneumatic cylinder, the Jetronic
-BOX HV also features an air pressure measurement and display function as well as the
corresponding adjustable pressure failsave function
To read the current operating data and to adjust settings, a suitable display and programming unit
(Engine Data Terminal) is required The following devices are supported:
Jetronic-Display EDT, no : 8830
Micro-EDT, no : 8832
Graupner BOOSTER-EDT no : 6813 10
Graupner ONBOARD-EDT no : 6813 7
These units are equipped with an illuminated alphanumeric display and can be connected and
disconnected while the system is running, or they can be permanently installed in the model
(ONBOARD-EDT)
Besides the current operating parameters, such as the battery voltage, it is also possible to display
additional information, such as air pressure or R/C inputs and outputs All display and adjustment
functions are accessible via a menu-controlled plain text dialog The JETRONIC-BOX is connected
to the R/C receiver via RC-1 normally, but RC-2 can be used as well (additional function)
Using a USB cable (type Jetronic-SIO2USB), the JETRONIC-BOX can be updated via the Internet,
making it possible to install new functions or extensions To do so, use the JetLog PC software
shipped with the Jetronic-SIO2USB cable
This makes the JETRONIC-BOX suitable for future model projects, too – for example, flashing
position lights, warning lights or special control functions are possible
evoJet GmbH
52379 Langerwehe
http://evoJet de
WEEE Reg Nr :
DE79530708
3

Jetronic-BOX HV Instructions 2.1
Schematic Overview 'Doorsequencer'
4

Jetronic-BOX HV Instructions 2.1
Factory Setting 'Doorsequencer'
Landing Gear with different Door Controls RC4 / RC5
RC3: The landing gear waits 1 second before retraction/extension
RC4: The door type-1 closes always automatically after a delay of 8 seconds (gear
extended) and after a delay of 6 seconds (gear retracted)
RC5: The door type-2 stays extended open closes after a delay of 7 seconds (gear
retracted)
RC2: A brake valve is controlled by a mixing function in the transmitter when the gear is
extended, e g from +100% to +150%
RC1 input: gear switch ON – extended / OFF – retracted
20:RC1-MODE: NORMAL
21:RC1-PRESET: OUT, after power on the landing gear extends
RC2 output: Single action brake valve
22:RC2-MODE: OUT-RC1
RC3 output: gear valve or servo
30:RC3-MODE: RC1-DIRECT
31:RC3-WAIT-OUT: 1 0 seconds, the landing gear waits before extend
32:RC3-WAIT-IN: 1 0 seconds, the landing gear waits before retract
33: to 37: any, depending on the servo or valve
RC4 output: door type-1 closes always automatically, valve or servo
40:RC4-MODE: RC1-TRIGGER, the door closes automatically
41:RC4-WAIT-OUT: 8 0 seconds, the door waits when extending
42:RC4-WAIT-IN: 6 0 seconds, the door waits when retracting
43: to 47: any, depending on the servo or valve
RC5 output: door type-2 stays extended open, valve or servo
50:RC5-MODE: RC1-DIRECT
51:RC5-WAIT-OUT: 0 0 seconds, the door opens immediately
52:RC5-WAIT-IN: 7 0 seconds, the door waits when retracting
53: to 57: any, depending on the servo or valve
RC6 output is not supported in this version
5

Jetronic-BOX HV Instructions 2.1
Jetronic Display EDT (Engine Data Terminal)
EDT-LEFT and EDT-RIGHT are configurable function displays for operating parameters In the
BOX-SETUP menu, you can choose what should be displayed in the LEFT and RIGHT areas
In the BOX-SETUP menu under 12:EDT→LEFT and 13:EDT→RIGHT, you can choose either to
display one of the R/C ports (RC1 to RC5) or an air pressure value [bar or psi]
In the lower line of the display, the voltage of the receiver system is shown as a bar graph that also
has a memory function for the minimum value (voltage under load) The measurement range can
be adapted to the battery type used in the BOX-SETUP menu under 10:R/C-BATTERY
6

Jetronic-BOX HV Instructions 2.1
JETRONIC-BOX – Setup
SETUP Menu
To activate the SETUP menu for changing the firmware configuration, first press the SET key, then
use the Up/Down keys to switch between the available items
To leave the SETUP menu and to return to the BOX status display, press the SET key for more
than 2 seconds (ESC) In the following, the individual submenus of the SETUP menu are
described
7

Jetronic-BOX HV Instructions 2.1
1:BOX-SETUP Menu
To activate the 1:BOX-SETUP menu, first press the SET key, then use the Up/Down keys to switch
between the available items
To leave the 1:BOX-SETUP menu and to return to the SETUP menu, press the SET key for more
than 2 seconds (ESC)
Pressing the SET key for more than 2 seconds again will return you to the operating status display
(>>> changes to <<<, ESC)
8

Jetronic-BOX HV Instructions 2.1
1:BOX-SETUP – Basic Settings for the Box
10:R/C-BATTERY
Specifies the type of battery used (required for a correct voltage display)
Ni = NiCd or NiMh, Li = lithium ion
Default setting: Ni4 (4.8V)
11:INFO-LED
Specifies the display function for the info LED on the top side of the device
OFF: No info LED function
RC1: Status of the RC1 remote control input: ON / OFF / NO signal => LED flashes
RC2: Status of the RC2 remote control input: ON / OFF / NO signal => LED flashes
Or display of the position switches if 20:RC2-MODE is set to POS -SWITCH
IR: Air pressure display via modulated flashing of the LED between 14:AIR-FAIL (LED => OFF)
and 15:AIR-NOMINAL (LED => ON)
ON: Info LED always on
Default setting: RC1
12/14:EDT~LEFT1/2
13/15:EDT~RIGHT1/2
Selects the display function for the left or right display area on the EDT line1/2
RC1: Remote control input RC1 – range: ON / OFF / NO
A ! marks the signal as FAIL signal, controlled by 14:AIR-FAIL and 24:@AIR-FAIL
A * marks the signal as preset-defined, configured by 21:RC1-PRESET
RC2: Remote control input RC2 – range: ON / OFF / NO
A ! marks the signal as FAIL signal, controlled by 14:AIR-FAIL and 24:@AIR-FAIL
A * marks the signal as preset-defined, configured by 23:RC2-PRESET
IR[bar]: Air pressure display in bar (kg/cm2) – range: 0 0 – 10 0 bar
A ! marks the signal as FAIL signal, i e pressure dopped below 14:AIR-FAIL
IR[psi]: Air pressure display in psi (lb/inch2) – range: 0 – 145 psi
A ! marks the signal as FAIL signal, i e pressure dopped below 14:AIR-FAIL
RC3/4/5: Output RC3/4/5 as servo travel in % – range: ±150 %
Default setting: RC1 und IR[bar]
16:AIR-FAIL
Specifies the minimum air pressure for the LED display (11:INFO-LED) as well as the safety setting
(24:@AIR-FAIL)
This parameter should be set to the minimum pressure value where the landing gear is still able to
extend and lock safely
Range: 0 0 bar – 15:AIR-NOMINAL
Default setting: 5.0 bar
9

Jetronic-BOX HV Instructions 2.1
17:AIR-NOMINAL
Specifies the nominal air pressure for the LED display (11:INFO-LED)
This parameter should be set to the pressure value nominally required for the model to take off
Range: 14:AIR-FAIL – 10 bar
Default setting: 8.0 bar
18: ET-DOOR EQ.
Resets the JETRONIC-BOX to the factory settings, a typical 'Doorsequencer'
See page 4 and page 5 for the overview and description
Default setting: NO
Set value to YES and push the SET-key two times
Landing Gear with different Door Controls RC4 / RC5
RC3: The landing gear waits 1 second before retraction/extension
RC4: The door type-1 closes always automatically after a delay of 8 seconds (gear
extended) and after a delay of 6 seconds (gear retracted)
RC5: The door type-2 stays extended open closes after a delay of 7 seconds (gear
retracted)
RC2: A brake valve is controlled by a mixing function in the transmitter when the gear is
extended, e g from +100% to +150%
19:FIRMWARE
Shows the actual firmware version
Value: 2.1
10