EXFO IQS-9100 Manuale utente

User Guide
Optical Switch for IQS platforms
IQS-9100

ii IQS-9100
Copyright © 2006–2008 EXFO Electro-Optical Engineering Inc. All rights
reserved. No part of this publication may be reproduced, stored in a
retrieval system or transmitted in any form, be it electronically,
mechanically, or by any other means such as photocopying, recording or
otherwise, without the prior written permission of EXFO Electro-Optical
Engineering Inc. (EXFO).
Information provided by EXFO is believed to be accurate and reliable.
However, no responsibility is assumed by EXFO for its use nor for any
infringements of patents or other rights of third parties that may result from
its use. No license is granted by implication or otherwise under any patent
rights of EXFO.
EXFO’s Commerce And Government Entities (CAGE) code under the North
Atlantic Treaty Organization (NATO) is 0L8C3.
The information contained in this publication is subject to change without
notice.
Trademarks
EXFO’s trademarks have been identified as such. However, the presence
or absence of such identification does not affect the legal status of any
trademark.
Units of Measurement
Units of measurement in this publication conform to SI standards and
practices.
Patents
EXFO’s Universal Interface is protected by US patent 6,612,750.
Version number: 2.0.0

Contents
Optical Switch iii
Contents
Certification Information ........................................................................................................v
1 Introducing the IQS-9100 Optical Switch .................................................... 1
Main Features .........................................................................................................................1
Available Models ....................................................................................................................2
Basic Switching Principles .......................................................................................................9
Typical Applications ..............................................................................................................11
Conventions ..........................................................................................................................15
General Safety Information ...................................................................................................16
2 Getting Started with Your Optical Switch ................................................ 17
Inserting and Removing Test Modules ..................................................................................17
Starting the Optical Switch Application ................................................................................22
Exiting the Application .........................................................................................................25
3 Operating the Optical Switch .................................................................... 27
Installing the EXFO Universal Interface (EUI) .........................................................................28
Cleaning and Connecting Optical Fibers ...............................................................................29
Optimizing the Application for Repeatability ........................................................................30
Selecting Configurations with the 1 x n Model .....................................................................31
Selecting Configurations with the 2 x 2 Model .....................................................................33
Selecting Configurations with the 2 x 4 Model .....................................................................34
Saving and Recalling Configurations .....................................................................................35
4 Controlling Multiple Optical Switch Modules .......................................... 37
Starting a Multimodule Application ......................................................................................37
Selecting Modules to Control ...............................................................................................38
Setting Parameters for Multiple Modules ..............................................................................39
Controlling a Single IQS-9100 Optical Switch .......................................................................42
Navigating and Closing Multiple Module Windows ..............................................................43
5 Monitoring Optical Switch Modules ......................................................... 45
Using Monitor Windows .......................................................................................................45
Using QuickTools ...................................................................................................................48
6 Maintenance ............................................................................................... 51
Cleaning Fixed Connectors ....................................................................................................52
Cleaning EUI Connectors ......................................................................................................54
Recycling and Disposal (Applies to European Union Only) ....................................................56

Contents
iv IQS-9100
7 Troubleshooting ..........................................................................................57
Solving Common Problems ...................................................................................................57
Obtaining Online Help ..........................................................................................................58
Finding Information on the EXFO Web Site ..........................................................................58
Contacting the Technical Support Group ..............................................................................59
Transportation ......................................................................................................................60
8 Warranty ......................................................................................................61
General Information .............................................................................................................61
Liability .................................................................................................................................61
Exclusions .............................................................................................................................62
Certification ..........................................................................................................................62
Service and Repairs ...............................................................................................................63
EXFO Service Centers Worldwide ..........................................................................................64
A Technical Specifications ..............................................................................65
B SCPI Command Reference ..........................................................................67
Quick Reference Command Tree ...........................................................................................68
Product-Specific Commands—Description ............................................................................69
Index .................................................................................................................89

Certification Information
Optical Switch v
Certification Information
F.C.C. Information
Electronic test equipment is exempt from Part 15 compliance (FCC) in
the United States. However, compliance verification tests are
systematically performed on most EXFO equipment.
Information
Electronic test equipment is subject to the EMC Directive in the European
Union. The EN61326 standard prescribes both emission and immunity
requirements for laboratory, measurement, and control equipment.
This unit has undergone extensive testing according to the European Union
Directive and Standards.

Certification Information
vi IQS-9100
Application of Council Directive(s): 73/23/EEC - The Low Voltage Directive
89/336/EEC - The EMC Directive
And their amendments
Manufacturer’s Name: EXFO Electro-Optical Engineering Inc.
Manufacturer’s Address: 400 Godin Avenue
Quebec, Quebec
Canada G1M 2K2
(418) 683-0211
Equipment Type/Environment: Test & Measurement / Industrial
Trade Name/Model No.: IQS-9100
Optical Switch
Standard(s) to which Conformity is Declared:
EN 61010-1:2001 Safety Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use, Part 1: General Requirements.
EN 55022: 1998 +A2: 2003 Limits and Methods of Measurement of Radio Disturbance
Characteristics of Information Technology Equipment.
EN 61326:1997 +A1:1998
+A2:2001 + A3:2003
Electrical Equipment for Measurement, Control and Laboratory
Use - EMC Requirements
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive and Standards.
Manufacturer
Signature:
Full Name: Stephen Bull, E. Eng
Position: Vice-President Research and
Development
Address: 400 Godin Avenue, Quebec (Quebec),
Canada, G1M 2K2
Date: January 7, 2002
DECLARATION OF CONFORMITY

Optical Switch 1
1 Introducing the IQS-9100
Optical Switch
Main Features
The IQS-9100 Optical Switch provides fiber-to-fiber positioning of optical
signals for a number of optical applications. This module, which exists in
various models depending on the number of optical ports and
configuration options it has, allows you to quickly switch light from one
fiber to another.
³This optical switch can be controlled using applications available in the
IQS Manager software
³The applications can control one or more modules at a time and allow
for various configurations.
³The configurations can be modified at any time and can be saved for
future use, allowing you to save time and be more efficient.
The IQS-9100 Optical Switch supports local control (via the IQS Manager
software) and remote control (through GPIB, RS-232, or Ethernet TCP/IP
using SCPI commands or the provided LabVIEW drivers). For more
information, refer to the IQS platform user guide.

Introducing the IQS-9100 Optical Switch
2IQS-9100
Available Models
Available Models
The different available switch configurations are shown in the following
figures, except for the 1 x 8 and the 1 x 24 optical switch models.
Note: Actual connectors may differ from those depicted in the illustrations.
1 x 2 Optical Switch Module
Switch ports 1 and 2
Common port
1 x 2
IQS-9100
Optical Switch
Retaining screw knob
LED push button

Introducing the IQS-9100 Optical Switch
Optical Switch 3
Available Models
1 x 4 Optical Switch Module
Switch ports 1 to 4
Common port
1 x 4
IQS-9100
Optical Switch
Retaining screw knob
LED push button

Introducing the IQS-9100 Optical Switch
4IQS-9100
Available Models
1 x 12 Optical Switch Module
Switch ports
1 to 12
Retaining screw knob
IQS-9100
1 x 12 Optical Switch
Common port
LED push button
Indice
Altri manuali EXFO Interruttore