F&F RS-407B Manuale utente

- 1 -
RS-407B
Bistable receiver
Electronic relays are used for radio remote control of gates,
shutters, lighting, arming alarm systems, etc. The remote control
system consis-ting of a transmitter (remote) and receiver (relay).
There is a possibility of cooperation between many transmitters
to one receiver and one transmitter to multiple receivers.
The RS-407B receiver works with dedicated devices
(transmitters) by F&F: RS-P (remote control) and RS-N
(flush-mounted transmitter).
The impulse caused by pressing a button on the remote control
sends a coded signal to the receiver. Remote control is protected
against break transmission after releasing the button. Thanks
to this, even the shortest activation function is the full frame of
data transmissions. Data transmission from the remote control is
indicated by flashing of red LED on the remote. When the signal
Purpose
Functioning
F&F Filipowski sp. j.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
Do not dispose of this device in the trash along with other waste!
According to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collec� on, as well as to store the occasion of
the purchase of new equipment (in accordance with the principle of old-for-new, regard-
less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the
environment and human health.

- 2 -
is recognized, the receiver will change the contact position to the
opposite (ON/OFF).
The range of the system is up to 100 m (range depends on many
factors, among others, on: the weather (humidity), terrain cha-
racteristics (reflection), placement of the receiver and transmit-
ter, and all kinds of obstacles such as walls).
Perform tests before final assembly of the receiver.
The receiver is equipped to the PROG button, which al-
lows link the remote/button on the receiver and resets
the receiver memory.

- 3 -
Press and hold the PROG button >5 sec enters into a state of pro-
gramming. After entering the learning mode, the receiver is wa-
iting for incoming transmissions from the remote (Pressing the
remote button). Followed by verification of the program. If the
button of the remote control has not been programmed it will
record identifying information. During one open programming
session, the receiver can be attributed to many control remotes.
The non-volatile memory can save up to 32 remotes. There is
a possibility of cooperation between many transmitters to one
receiver and one transmitter to multiple receivers.
Short press <1 sec exits from the state of programming.
Press and hold PROG >8 sec will erase the memory. After the
operation, erasing out of the non-volatile memory are erased
all data on the pilots, and then the memory is formatted for
re-programming.
Programming

- 4 -
Red LED
Flashing every 1 sec Learning mode
ON Signalling of switch-on the relay
Green LED
After turn-on the power:
Single blink Device initialization
Working:
Short random blinks Receiving data from remote controls
Learning (red LED is flashing at the same time):
Long blink Memorization of button functions
Short blink Button is already stored in the me-
mory
3 blinks Full memory
Reset settings:
After pressing the PROG button for 8 seconds, it starts blin-
king quickly, confirming that the settings have been deleted
Signalling of the receiver state

- 5 -
1.Disconnect power supply.
2.Connect the power cables to the relay in accordance with the
markings; L-phase wire to black conductor, N-neutral wire to
blue conductor.
3.The controlled receiver should be connected in series to the
terminals X1 and X2 of the relay (brown wires).
4.Pair the relay with the transmitter (programming).
5.Connect power supply.
Mounting
Wiring diagram

- 6 -
power supply 195÷253 V AC
maximum load current (AC-1) 5 A
contact separated 1×NO
contact status signalling red LED
receipt/programming signalling green LED
radio frequency 868 MHz
power consumption 0.8 W
working temperature -25÷50°C
terminal 4×LY 1 mm², l= 10 cm
dimensions ø55, h= 21 mm
mounting for ø60 flush-mounted box
ingress protection IP20
Technical data

- 7 -
E200722
The F&F products are covered by a warranty of the 24 months
from the date of purchase. Effective only with proof of purchase.
Contact your dealer or directly with us.
F&F Filipowski sp. j. declares that the device is in conformity
with the essential requirements of Directive 2014/53/EU of the
European Parliament and of the Council of 16 April 2014 on the
harmonisation of the laws of the Member States relating to the
making available on the market of radio equipment and repe-
aling Directive 1999/5/EC.
The CE Declaration of Conformity, along with the references to
the standards in relation to which conformity is declared, can be
found at www.fif.com.pl on the product page.
PN-EN 60669, PN-EN 60950, PN-EN 55024, PN-EN 61000,
PN-ETSI EN 300 220-1, PN-ETSI EN 300 220-2,
PN-ETSI EN 301 489-1, PN-ETSI EN 301 489-3.
Warranty
CE declaration
Compliance with standards

Indice