DRVRMOTL
Motorized Linear Drive
DRVRMOTLR
Motorized Linear and Rotary Drive
DRVRMOTLRR
Motorized Linear and Double Rotary Drive
Instruction
Manual
Revision B
05.MAY 2023

DRVRM Technical Reference Manual
2/14
May 23 REV B
Warranty
Ferrovac GmbH warrants this product to be free of defects in material and workmanship for a period
of 12 months from the date of shipment.
In case of proof of any defective parts in the product, we will at our option, either repair the product
or replace it.
Warranty Limitations
The warranty for this product does not apply to defects resulting from the following:
non-observance of operational- and safety instructions
natural wear of components
modifications to our products without our written consent
misuse of any product or part of the product
This warranty stands in place of all other warranties, implied or expressed, including any warranty of
merchantability implied or fitness for a particular use. The remedies provided herein are buyer’s sole and
exclusive remedies.
Neither the company Ferrovac GmbH nor any of its employees shall be liable for any direct, indirect, incidental,
consequential or special damages arising out of the use of its products, even if the company Ferrovac GmbH has
been advised in advance of the possibility of such damages. Such excluded damages shall include but are not
limited to: Costs of removal and installation, losses sustained as the result of injury to any person, or damage to
property.
Copyright
Copyright 2014, Ferrovac GmbH. All rights reserved. All information in this document is the sole
property of Ferrovac GmbH and is protected by Swiss copyright laws and international conventions.
Ferrovac GmbH grants the right for reproduction for the purchasers own use. No part of this manual
may be reproduced or transmitted by any third party in any form or by any means and for any
purpose without the written permission of Ferrovac GmbH.

DRVRM Technical Reference Manual
3/14
May 23 REV B
Content
WARRANTY 2
WARRANTY LIMITATIONS 2
COPYRIGHT 2
CONTENT 3
TERMS AND SYMBOLS 4
NORMAL USE 4
1. INTRODUCTION 5
1.1. DRVRMOTL 5
1.2. DRVRMOTLR 5
1.3. DRVRMOTLRR 5
2. UNPACKING AND INSPECTION 5
3. OVERVIEW 6
3.1. NOMENCLATURE 7
3.2. HANDLING & ADJUSTING OF THE LIMIT SWITCHES 8
3.2.1. FRONT LIMIT SWITCH 8
3.2.2. REAR LIMIT SWITCH 9
3.2.3. ROTATION LIMIT SWITCHES 9
3.3. MOUNTING 11
3.4. TUBE SUPPORT 11
3.5. BAKEOUT 12
4. PROBLEM SOLVING 13
4.1. FACTORY OVERHAUL 13
4.2. DECLARATION OF DECONTAMINATION 13
4.3. DOWNLOAD 13

DRVRM Technical Reference Manual
4/14
May 23 REV B
Terms and Symbols
The information in this document represents the state of the product at the date of print. Technical
changes may be made without notice. Ferrovac GmbH makes no warranties or representations with
respect to accuracy or completeness of the contents of this publication. Figures and photos are not
binding. The used product names are for identification purposes and may be trademarks of their
respective companies.
A triangle with explanation mark indicates a passage in the manual with information
that is crucial for the operator. READ THESE PARAGRAPHS CAREFULLY or the product
might be damaged by misuse.
CAUTION! The CAUTION heading in a manual explains hazardous situations that could damage
the product. Such damage may invalidate warranty.
Normal Use
The product described in this manual must always be used:
With original accessories supplied by Ferrovac which are explicitly specified for the use with
the product described in this publication.
In an indoor research laboratory environment.
By personnel qualified for operation of delicate scientific equipment.
In accordance with this and all related manuals.
CAREFULLY READ THE SAFETY INFORMATION AND ALL RELEVANT MANUALS
BEFORE USING THE PRODUCT AND ANY RELATED INSTRUMENTATION!

DRVRM Technical Reference Manual
5/14
May 23 REV B
1. Introduction
1.1. DRVRMOTL
Motorized linear and manual rotary drives are designed to operate sample transporters and
optionally attached sample locking mechanisms such as a pincer grip. The DRVRMOTL linear drive is
compatible with RM40, RMD40, RMDG40 and GMD40. For these sample transporters, a variety of
Ferrovac sample receivers, carriers and pincers are available. The motorized linear drive still allows
for manual rotation of the shaft for sensitive application of the rotation of your sample holder or
when opening/closing the pincer. Rotation can be locked using a thumbscrew.
1.2. DRVRMOTLR
Motorized linear and rotary drives are designed to operate sample transporter and optionally
attached sample locking mechanisms such as a pincer grip. The DRVRMOTLR linear and rotary drive
is compatible with RM40, RMD40, RMDG40 and GMD40. For these sample transporters, a variety of
Ferrovac sample receivers, carriers and pincers are available. Single rotation and linear movement is
completely motorized. Thus opening/closing of pincers or rotation of you sample carrier is easily
done from your workstation.
1.3. DRVRMOTLRR
Motorized linear and rotary drives are designed to operate sample transporters and to optionally
attached sample locking mechanisms such as a pincer grip. The DRVRMOTLRR linear and double
rotary drive is only compatible with RMDG40 sample transporters (as only this model has two
rotatable axis). For this sample transporter a variety of Ferrovac sample receivers, carriers and
pincers are available. Double rotational axis and linear movement is completely motorized. Thus
opening/closing and rotation of pincers or rotation of your sample carrier is easily done from your
workstation.
2. Unpacking and Inspection
Motorized sample transporters are shipped clean and ready to use in UHV. Prepare a sufficiently
clean workspace and wear surgical gloves when unpacking and inspecting the device. Check for any
visible damage of the package, manipulator and accessories. Compare the contents of the package
with the delivery note. Any damage or missing items must be reported to Ferrovac within 48 hours
after delivery.

DRVRM Technical Reference Manual
6/14
May 23 REV B
CAUTION!
Always use powder-free examination gloves during unpacking to avoid contamination.
Please ensure enough working space for unpacking and inspection.
Please clean the working table/surface and cover it with Aluminium foil or household foil.
Never hit the knife edge nor the bellows.
Never expose the Sample Transporter to physical shocks (brittle magnets!!!).
Never bend the tube nor the shaft.
3. Overview
The main purpose of RM40, RMD40, RMDG40 and GMD40 sample transporters with motorization is
to transfer samples over longer distances.
Fig. 1; Sample Transporter with Linear Motorization RM40-XXXX-YYYY-DRVRMOTL

DRVRM Technical Reference Manual
7/14
May 23 REV B
Fig. 2; Single Rotation & Linear Sample Transporter Motorization DRVRMOTLR
Fig. 3; Double Rotation & Linear Sample Transporter DRVRMOTLRR

DRVRM Technical Reference Manual
8/14
May 23 REV B
3.1. Nomenclature
The main parts of the linear motorization DRVRMOTL are named as follows:
Fig. 4; DRVRMOTL Nomenclature

DRVRM Technical Reference Manual
9/14
May 23 REV B
The main parts of the double rotary motorization DRVRMOTLRR are named as follows:
Fig. 5 DRVRMOTLRR Nomenclature
The same nomenclature applies to the single rotary motorized DRVRMOTLR.
3.2. Handling & Adjusting Of the Limit Switches
3.2.1. Front Limit Switch
All motorizations for Ferrovac sample transporters have an adjustable limit switch, with which you
can define your max. extended length of the sample transporter. Undo the small screw on the side of
the limit switch housing to adjust it’s position.
The front limit switch of all sample transporter
motorizations (DRVRMOTL, DRVRMOTLR,
DRVRMOTLRR) is connected to pins 9 and 18 on
the 26P D-Sub connector.
The switch is a reed switch, which is operated by an applied magnetic field. This switch is normally
closed wired and opened by the switch action (position is reached).
Fig. 6; Front Limit Switch

DRVRM Technical Reference Manual
10/14
May 23 REV B
3.2.2. Rear Limit Switch
You find the rear limit switch at the rear end of the motorization (directly under the spindle unit).
The position of it is not adjustable.
The front limit switch of all sample transporter motorizations
(DRVRMOTL, DRVRMOTLR, DRVRMOTLRR) is connected to pins 8
and 17 on the 26P D-Sub connector.
3.2.3. Rotation Limit Switches
Each rotational unit has two limit switches (start- & end-position). The start- and the angle of the
end-position can easily be adjusted by 3 grub screws (3 screws/position).
Fig. 7; Rot. Limit Switch DRVRMOTLR
For the DRVRMOTL & DRVRMOTLR motorizations, the switches can also be connected as "normal
open". However, it is highly recommended to connect as "normal closed"!
CAUTION: Risk of squashing/crushing!
Never touch the motorized sample transporter during movement!
CAUTION: Risk of squashing/crushing!
Never touch the motorized sample transporter during movement!
Questo manuale è adatto per i seguenti modelli
2
Indice
Manuali Azionamento CC popolari di altre marche

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Manuale utente

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Manuale elenco delle parti

Chamberlain Garog
Chamberlain Garog D Series Manuale utente

Parker
Parker PDS Series Manuale utente

Festo
Festo DGC G Series Guida all'installazione

Binks
Binks QS-5012-1-CE Manuale utente