Go to fetco.com for the latest versions of all information Page 8User Guide & Operator instructions P209 REV001 February 2023
Brewer Operation Control Settings, Adjust Brew Flow Rate
POSITION Program Items Factory set Default Programming Range Increments Notes
B1 Tank Temp. 200°F-or-93°C
170° to 207°F
77° to 97°C
Chart to correct for
high altitude below
B3 Batch Temp OFF ON/OFF ON/OFF
For tea brewing
temperature for A190
B4
YES YES/NO
To display HW tank
temperature on screen
B5
Units of Measure
TEMPERATURE
° Fahrenheit Fahrenheit/Celsius C/F
NOTE: Overwrites
user settings (see page 9)
B6
Ounces Ounces/Liters/Gallons Oz/L/Gal
NOTE: Overwrites
user settings (see page 9)
B7 Customer Name Off NO or YES For name on screen
B8 Customer Name
Scroll with batch keys A-Z;a-z;0-9 16 characters total
B9 Demo Mode OFF DEMO ON/OFF
Demonstrates the controls
for training. Disables all
B10 Eco Mode Off ON/OFF YES/NO
water tank temperature after
preset time of inactivity
B11 Eco Idle Time
(turns on if B10 active) 1Hr 1-6 hours 1 hour Time of inactivity to go into
ECO Mode
B12
(turns on if B10 active) 169°F 158-176°F 1 degree Temperature that hot water
tank is lowered to
B13 Filter Life OFF ON/OFF YES/NO
Water filter life is accessed
in G-Counters. This is user
set and will display indicator
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: “ON”
(FACTORY DEFAULT FOR BREWER)
“BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show “HEATING”
and hot water tank temperature
The “BREW START” entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-
will allow brew at low temperature.
Extracted tea flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-
will allow brew at low temperature.
Tea flavor will be noticeably affected
Tank temp
STOP is not lit
& BREW START
buttons not lit.
and are disabled.
Batch menu
button(s ) will
illuminate and
“READY”
on screen when hot
water tank
temperature is at
brew temp setpoint.
FETCO
Ready to Brew
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at reduced temperature
Allows brewing at any temperature above 169°F/76°C
Chart to correct for altitude for boiling point
in hot water tank water temperature.
[ft] [m] Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C]
Boiling
point [°C]
STOP