Translation of the original instructions with installation instructions, Filter aid dosing device SDG-100, Filtration Group GmbH, 16.01.19, Mat. No.
79792383, Version 04
1 Contents
1Contents...................................................................... 2
2General safety instructions....................................... 2
2.1 Safety instructions for installation and
operating personnel .......................................... 2
2.2 Warning structure.............................................. 2
2.3 Warning symbols used...................................... 2
2.4 Other symbols used.......................................... 3
3Glossary...................................................................... 3
4General information ................................................... 3
4.1 Manufacturer..................................................... 3
4.2 Information about the original instructions ........ 3
4.3 Model code ....................................................... 4
5Intended use............................................................... 4
6Functional description............................................... 5
6.1 Principle of the process..................................... 5
6.2 Main components.............................................. 5
7Technical data ............................................................ 6
7.1 General data (excluding optional equipment) ... 6
7.2 Order-specific data............................................ 6
8Transport and storage ............................................... 6
9Installation .................................................................. 6
9.1 Installation......................................................... 7
9.2 Installing the piping / pump selection ................ 7
9.3 Compressed air supply ..................................... 7
9.4 Electrical connections ....................................... 8
9.4.1 Connection of the 2/2-way valves.......... 8
9.4.2 Calibrating the level sensor (optional).... 8
9.4.3 Dosing device controller (optional) ........ 8
10 Start-up ....................................................................... 8
10.1 Initial start-up or start-up after prolonged
shut-down ......................................................... 8
10.2 Starting up the dosing device............................ 8
11 Normal operation ....................................................... 8
12 Shutting down the dust collector ............................. 9
12.1 Temporary shut-down....................................... 9
12.2 Prolonged shut-down (> 48 h)........................... 9
12.3 Emergency shut-down ...................................... 9
12.4 Transporting the dosing device......................... 9
13 Troubleshooting......................................................... 9
14 Maintenance ............................................................... 9
14.1 Inspection and maintenance schedule.............. 9
15 Appendix: Dosing device parameters .................... 10
16 Declaration of incorporation ................................... 11
17 Index.......................................................................... 15
2 General safety instructions
2.1 Safety instructions for installation and
operating personnel
This translation of the original instructions contains
important safety information which must be heeded at all
times during installation, normal operation and maintenance.
Non-observance can result in the following risks to persons
and the environment as well as in damage to the machine or
system:
Failure of critical functions of the machine or system or of
its component parts.
Danger to persons from electrical or mechanical effects
as well as from chemical reactions.
Danger to the environment owing to the leakage of
hazardous substances.
Before installation / start-up:
•Read this translation of the original instructions carefully.
•Make sure that installation and operating personnel are
adequately trained.
•Make sure the contents of the original instructions are
fully understood by the responsible persons.
•Define areas of responsibility and competence.
•Prepare a maintenance schedule.
During operation of the system:
•Keep this translation of the original instructions handy at
the place of use.
•Heed the safety instructions. Always operate the machine
or system in accordance with its ratings.
If in doubt:
•Consult the manufacturer.
2.2 Warning structure
Where possible, warnings are structured according to the
following system:
Possibly
with
symbol
Nature and source of the danger
Potential consequences of non-
observance
•Action to avert the danger.
2.3 Warning symbols used
Immediate danger!
Non-observance will result in serious or fatal injury.
Potentially dangerous situation!
Non-observance can result in serious or fatal injury.
Potentially dangerous situation!
Non-observance can result in minor or moderate
CAUTION! (without a symbol)
Potentially dangerous situation!
Non-observance can result in property damage.