REV. A Page 2
ESTOP-RM-KIT
PRODUCT DESCRIPTION: This ESTOP-RM-KIT is surface mounted design to be installed with a
Firegear Outdooors Match Throw (MT) re pit, a Thermocouple Manual Safety (TMSI) re pit or BBQ grill applications.
Use either the ESTOP1-0H or ESTOP2-5H gas timer models with this kit. The ESTOP Gas Timer is not supplied with this
kit and must be purchased seperately. The ESTOP gas timers must be oriented in the upright position as shown in the
instructions. NOTE: All gas lines must enter from the back side of the ESTOP gas timer to use this mounting kit. Ensure
to install the plugs provided with the ESTOP gas timer and seal them with gas rated Teon tape before installing
this ESTOP-RM-KIT.
FOLLOW LOCAL CODES IF APPLICABLE FOR THIS INSTALLATION
INSTALLATION
Step 1: Use the four (4) screws provided in the ESTOP
gas timer box and install the two (2) mounting brackets to
each side of the ESTOP as shown in Fig. 1.
Tools Needed: Power Screwdriver with a Phillips head tip,
5/16” wrench or nut driver.
Step 3: Cut a 3⅛” wide x 4 ¾”tall hole into the wall board
where the ESTOP is to be located.
Step 4: Place the ESTOP into the hole and mark the
mounting hole brackets. Ensure assembly is centered and
level, then drill four ¼” holes in the wall for mounting. See
Fig. 3.
Step 2: After brackets are installed, the ESTOP gas timer
should look like Fig. 2.
Fig. 1 Installing mounting brackets to ESTOP gas timer.
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
Fig. 2 Shows front view of ESTOP with mounting
brackets installed.
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
Hole in Wall Board
Fig. 3 Installing ESTOP gas timer into wall.
4 ¾”
3⅛”