fortessa FTDEV1 Series Manuale utente

USER MANUAL
• Please read this manual carefully to ensure safe and correct operation.
• Keep this manual well for future reference.
FTDEV1 FTDEV2P
FTDEV1 Series
2 WIRE SYSTEM


CONTENTS
PARTS AND FUNCTIONS..................................................................................... 1
Part Names............................................................................................................. 1
Mounting................................................................................................................. 1
External Motion Detection ...................................................................................... 2
SETUP INSTRUCTIONS........................................................................................ 3
Functions Setting Up .............................................................................................. 3
Setting Door Station Address ................................................................................. 4
Setting Door Station Calling Mode ......................................................................... 4
Setting Unlock Mode .............................................................................................. 6
Setting Unlock Time................................................................................................ 6
Setting Nameplate Illumination Mode..................................................................... 7
Setting Night View LED Illumination Mode............................................................. 7
Setting Ring-back Tone .......................................................................................... 8
WIRING .................................................................................................................. 9
Connecting Electric Lock........................................................................................ 9
Connecting Basic One-to-one ............................................................................... 10
Connecting Multi Door Stations............................................................................. 10
Connecting Multi Monitors..................................................................................... 11
APPENDIX ............................................................................................................ 13
Precautions............................................................................................................ 13
Specication .......................................................................................................... 13
Cables and Requirments....................................................................................... 14

-1-
Part Names
PARTS AND FUNCTIONS
[11] [10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rain shield
[11] Mounting bracket
[12] Connection
[13] Front Panel Screw
Mounting
1 2 3 4 5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
Main unit
≥3mm
1. Connect the cable correctly.
2. Use the appropiate xing, then attach the rain shield and main unit to the wall, the distance
between the top of main unit and rain cover should be not less than 3mm.
3. Install the name plate.
4. Attach the front panel to the main unit.
5. Use the special screwdriver and the screw to x the panel.
The installation height is suggested to 145~160cm.

-2-
PARTS AND FUNCTIONS
Terminal description
Lock Control Jumper: To select the lock type.
Motion Detector Terminals: To connect external PIR motion detector. * (compatible monitor
required)
Terminal Connections: To connect the bus line and the electronic locks.
• L1,L2: Connect to the bus line, Non polarity.
• PL: External lock power input, connect to the power positive (power +).
• S+: Lock power (+) output.
• S-: Lock power (-) output, connect to the power (-) input of locks (only use and connect if the
door panel is powering the lock directly. DO NOT use if a remote PSU is powering the lock).
1 2 3
Lock Control Jumper
PIR Motion Detector
Terminal
* (compatible monitor required)
+12V
GND
PIR
L1 L2
PL
S+ S-
Terminal Connections
External Motion Detection
* Note: The supplied monitor (FTDEVM43) in the
kit does not support motion detection function.
The door station is equipped with a terminal to
connect external motion detector.
If the external motion detector is connected to
the system,following functions will be effective:
If detect someone passing by, the door station can be activated operation to unlock or turn on
light.
12V
Motion
detector
GND
PIR

-3-
SETUP INSTRUCTIONS
Functions Set Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
This section explains the settings of each
function, please refer to the following ta-
ble:
To perform the function settings, remove
the metal front panel.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sound of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2Setting door station
calling mode Standard/Group calling mode Standard calling mode
3 Setting the unlock mode 0:opened/1:closed 0:opened
4 Setting the unlock time 01 to 99 seconds 1 seconds
5Setting the nameplate
illumination mode On/Off/Auto On
6Setting night view LED
illumination mode On/Off/Auto Auto
7 Setting ring-back tone
Ring Once
Ring continuously
No ring-back tone
Ring Once

-4-
Setting Door Station Address
Setting Door Station Calling Mode
A maximum of 4 door station can be addressed and congured. This can be modied either be-
fore or after installation.
0 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
SETUP INSTRUCTIONS
• During Setting Mode, you can change the address of door station by pressing KEY1~4 at any time.
• The LED_NAME indicator will continue to blink while in Setting mode.
• The Setting Mode will exit 10 seconds after the last button has been pressed.
• To exit Setting Mode, press KEY_SET button four times.
There are two calling modes for door station,Standard calling mode and Group calling mode.
The door station default is Standard Calling mode.

-5-
• During Setting Mode, you can change the calling mode by pressing KEY1 repeatedly.
• The LED_NAME indicator will continue to blink while in Setting mode.
• The Setting Mode will exit 10 seconds after the last button has been pressed.
• To exit Setting Mode, press KEY_SET button three times.
SETUP INSTRUCTIONS
* More details about code setting for monitor, please refer to corresponding user manual .
Each call button will respond to different addresses when set in different calling mode. Refer to
the followings for more informations.
Call buttonA: call the monitor with address 01 by default.
Call buttonB: call the monitor with address 02 by default.
Call buttonA: Call all monitors in group address from
00~15.(one of the monitor should be set to 00)
Call buttonB: Call all monitors in group address from
16~31. (one of the monitor should be set to 16)
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+
Press KEY_1 button to
activate Standard calling
mode for door station.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to activate Group calling
mode for door station.
Press KEY_1
A A
B
1.Standard calling mode(Address range 01-04
by default)
2.Group calling mode
To change this setting:

-6-
SETUP INSTRUCTIONS
Setting Unlock Mode
There are 2 unlock modes, Normally open and Normally closed.
Normally open is default, to change the setting:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally open.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
• During Setting Mode, you can change the unlock mode by pressing KEY1 repeatedly.
• The LED_NAME indicator will continue to blink while in Setting mode.
• The Setting Mode will exit 10 seconds after the last button has been pressed.
• To exit Setting Mode, press KEY_SET button twice.
Setting Unlock Time
By default, the unlock time is 1s, this can be altered from 1s~99s.
Follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time.
• When entering time delayed setting, the buzzer sounds once for every second.
• The LED_NAME indicator will continue to blink while in Setting mode.
• The Setting Mode will exit 10 seconds after the last button has been pressed.
• To exit Setting Mode, press KEY_SET button twice.

-7-
SETUP INSTRUCTIONS
Setting Nameplate Illumination Mode
There are 3 illumination modes for nameplate indicator, Normally on, Normally off and Auto.
Normally on is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally on.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_3 button again
and again to set the nameplate
illumination mode to Auto.
Press KEY_3
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
repeatedly.
• The LED_NAME indicator will continue to blink while in Setting mode.
• The Setting Mode will exit 10 seconds after the last button has been pressed.
• To exit Setting Mode, press KEY_SET button twice.
Setting Night View LED Illumination Mode
There are 3 working modes for night view LED indicator, Normally on, Normally off and Auto.
Auto is default, to change the setting:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_4 button to set
the night view LED mode
to Normally on.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_4 button again
to set the night view LED
mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_4 button again
and again to set the night
view LED mode to Auto.
Press KEY_4
• If setting mode has not been exited, you can change the night view LED illumination mode by pressing
KEY4 repeatedly.
• The LED_NAME indicator will continue to blink while in Setting mode.
• The Setting Mode will exit 10 seconds after the last button has been pressed.
• To exit Setting Mode, press KEY_SET button twice.
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali fortessa Sistema di interfono