fortessa FTDEV1P Manuale utente

2 -Wire Intercom System
FTDEV1PUser Manual
FTDEV1P_Instructions _Rev02
FTDEV1P

CONTENTS
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Specications ...................................................................................................... 2
4.Mounting .............................................................................................................. 2
4.1 Mounting Without Rainy Cover ...................................................................... 2
4.2 Mounting With Rainy Cover ........................................................................... 3
4.3 Placing Name Label ...................................................................................... 3
4.4 Adjusting Camera Angle ................................................................................ 4
5.System Wiring and Connections ......................................................................... 4
5.1 Basic Connection........................................................................................... 4
5.2 Electric Lock Connection ............................................................................... 5
5.2.1 Door Lock Controlled with Internal Power ............................................ 5
5.2.2 Door Lock Controlled with Dry Contact ................................................ 5
5.2.3 How to setup the unlock parameter in Monitor ...................................... 6
5.3 Multi Doorstations Connection....................................................................... 7
5.4 Multi Monitors Connection ............................................................................. 8
5.4.1 Basic IN-OUT Wiring Mode ................................................................. 8
5.4.2 With DBC-4 Wiring Mode .................................................................... 9
6.Setup ................................................................................................................... 10
6.1 DIP Switches Settings of Doorstation ............................................................ 10
6.2 DIP Switches Settings of Monitor .................................................................. 10
6.3 Notices........................................................................................................... 12
7.Cables Requirements .......................................................................................... 13

-1-
1.Parts and Functions
Rainy Cover
Camera Lens
Night View LED
Speaker
Nameplate
Call Button
Microphone
90 mm
176 mm
23 mm
2.Terminal Descriptions
BUS
PL
S1+ S2+ S-
1 2
ON
12
ON
MIC adjustment
Lock Control Jumper
Doorstation Code DIP
Main Connect Port
1 2 3
SPK adjustment

-2-
•Lock Control Jumper: To select the lock type: see 5.2.1 , 5.2.2
•Doorstation Code DIP: Total 4 doorstations can be supported,see 6.1
•Main Connect Port: To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
•PL: External lock power input, connect to the power positive(power +).
•S1+, S2+: Lock power(+) output, to connect 2 locks.
•S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to
power the locks, if using the external power supply for the locks, the S- will not be connected).
Lock Power supply: 12Vdc, 300mA(Internal Power)
Power Consumtion: 1W in standby, 12W in working
NO, COM dry contact: Max. 48V dc 1.5A
Unlocking time: 1 to 9 seconds, set by Monitor
Working temperature: -10ºC ~ 45ºC
4.Mounting
4.1 Mounting Without Rainy Cover
160-165cm
1
2
1 2 3 4
IP rating: IP43

-3-
4.2 Mounting With Rainy Cover
160-165cm
1
2
1 2 3 4
4.3 Placing Name Label
Move the plastic cover away to open the transparent name label cover, insert a name paper, then put
the plastic cover back to the panel.
name label
1 2
ON

-4-
4.4 Adjusting Camera Angle
5.1 Basic Connection
use a screwdriver to loosen the screw and then adjust
5.System Wiring and Connections
-
+
AC~
12
ON
L1 L2 PL S1+ S2+ S-
FTDEV1PSU
Fail Secure Lock
monitor
monitor

-5-
5.2 Electric Lock Connection
5.2.1 Door Lock Controlled with Internal Power
connect one lock connect two locks
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
EB
*
LOCK
BUS PL S1+ S2+ S-
LOCK
2nd
1ST
2nd
EB
*1ST
Jumper position in
Connect two locks
1-2
EB
*
LOCK
BUS PL S1
+
S2
+S-
Jumper position in
Connect one lock
1-2
5.2.2 Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the Unlock Mode of Monitor for different lock types.
• Power-on-to-unlock type:Unlock Mode=0 (by default)
• Power-off-to-unlock type:Unlock Mode=1

-6-
LOCK
BUS PL S1
+
S2
+S-
Take off the Jumper
POWER
SUPPLY
LOCK
BUS PL S1
+
S2
+S-
Take off the Jumper
POWER
SUPPLY
LOCK
connect one lock connect two locks
5.2.3 Unlock parameter setting(set on monitor)
Note:
1.must connect FTDEV1Pcorrectly before setting.
2.the parameter will be saved in FTDEV1Pautomatically,so you need only set on one monitor.
refer to the corresponding user manual.
The door release time can be adjusted from 1s~9s by following the below step:
On the video monitor, touch on main menu, then press UNLOCK button
and hold for 2s which you then enter Installer Setup page.
Then input the code 8021~8029 (8021 = 1 second, 8029 = 9 seconds) to change
the unlock time.

-7-
5.3 Multi Doorstations Connection
85~260VAC
DPS PS5
monitors
12
ON
L1 L2 PL S1+ S2+ S-
12
ON
L1 L2 PL S1+ S2+ S-
12
ON
L1 L2 PL S1+ S2+ S-
12
ON
L1 L2 PL S1+ S2+ S-
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1# Camera
ID=00
ID=10
ID=01ID=11
2# Camera3# Camera4# Camera
DBC4
A B C D
BUS

-8-
5.4.1 Basic IN-OUT Wiring Mode
5.4 Multi Monitors Connection
ID=00
1 2
ON
Code=0, DIP-6=off
1 2 3 4 5 6
ON
Code=3, DIP-6=off
1 2 3 4 5 6
ON
Code=2, DIP-6=off
1 2 3 4 5 6
ON
monitor
Code=1, DIP-6=off
1 2 3 4 5 6
ON
monitor
monitormonitor
BUS(IM) BUS(DS
FTDEV1PSU8
AC~
100~240VAC
monitor monitor monitor monitor
Code=4, DIP-6=off Code=5, DIP-6=off Code=6, DIP-6=off
ON
1 2 3456
ON
1 2 3456
ON
1 2 3456
ON
1 2 3456
Code=7, DIP-6=on
Indice
Altri manuali fortessa Sistema di interfono