Genquip Gi2000 Manuale utente

page 1Genquip Gi2000 Digital Inverter Petrol Generator
Genquip Gi2000 Digital Inverter Petrol Generator
Owners Manual

page 2 Genquip Gi2000 Digital Inverter Petrol Generator
Notes

page 3Genquip Gi2000 Digital Inverter Petrol Generator
Control Function 4
Pre Operation Checklist 5
• Fuel System
• Check Fuel Level
Control Function Continued 6
• Engine Oil
• Oil Warning System
• Engine Switch
• DC Protector
Operation 7
• Starting The Engine
Periodic Maintenance 8
Spark Plugs 9
Engine Oil Replacement 10
Air Filter 11
Fuel Tank Filter 11
Genquip Safety 12
Operating Procedure 13
• Visual Inspection
• Start Up
• Shutdown
Potential Hazards 14, 15
and Risk Assessment
Maintaining your Generator 16
• Cleaning
• Storing or Transporting
• Servicing
Specifications & Dimensions 17
Troubleshooting 18, 21
• Engine Won’t Start
• Generator Won’t Produce Power
• Storage : Drain The Fuel
• Storage : Engine
Warranty 22
Notes 23
Table of Contents

page 4 Genquip Gi2000 Digital Inverter Petrol Generator
Control Function
1. Control Panel
2. Fuel Tank Cap
3. Maintenance Cover Screw
4. Choke Level
5. Front Side Maintenance Cover
6. Recoil Starter
7. E ngine S w i tc h
8. Fuel Drain Hose 1
9. Fuel Drain Hose 2
10. 240 Volt Sockets
11. Carry Handles
12. DC Circuit Protector
13. DC Socket
14. Fuel Saver Switch
15. Oil Alert Indicator Light
16. Overload Indicator Light
17. Output Indicator Light
18. AC Socket
19. Ground (Earth) Terminal
5
8
9
7
6
10
1
2
11
3
4

page 5Genquip Gi2000 Digital Inverter Petrol Generator
Pre Operation Checklist
NOTE: Pre-operation checks should be made each time
the generator is used.
Fuel System
Make sure there is sufficient fuel in the tank. The engine
must use regular unleaded petrol only and the fuel tank
capacity is 4 litres.
Check the Fuel Level.
1. Make sure the generator is turned off, by rotating the
engine switch (7) to the off position. (Fig. D).
2. Check the fuel by a visual check. Remove the fuel cap
and fuel filter screen reviewing the fuel level (Fig. E).
3. If fuel is low, replace the filter screen inside the fuel
tank neck (Fig. F).
4. Pour in unleaded fuel from an approved fuel container
into the fuel tank.
19
14
15
16
17
18
12
13
Figure D.
Figure E.
Figure F.

page 6 Genquip Gi2000 Digital Inverter Petrol Generator
WARNING: Fuel is high flammable and poisonous.
DO NOT fill above the top of fuel filler or it may overflow
when the fuel heats up and expands.
Wipe up any spilled fuel immediately.
After refueling, make sure the tank cap is tightened.
Engine Oil
Make sure the engine oil is at the upper level of the oil filler hole. Add oil as necessary.
Recommended oil for most climates is 10W30. Engine oil quantity is 450 millilitres.
Oil Warning System
If the oil level falls below the safe operating level, the engine will stop automatically. Unless
you refill with oil, the engine will not start again.
Note: If the engine stalls or does not start, turn the engine switch to “ON” position and
then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil
is low. Add oil and restart.
DC Protector
The DC Protector turns of automatically when the loads exceeds the generator rated output.
NOTE: If the DC Protector trips to the OFF position, press to reset. Reduce the load to
the specified generator output if the DC protector turns off. If it turns off again, consult
the authorized dealer.
ON
(PUSH)
PROTECTOR
OFF

page 7Genquip Gi2000 Digital Inverter Petrol Generator
Operation
Starting The Engine
NOTE: Before starting the engine, ensure you have filled the crankcase to the correct
level with oil. The crankcase is not filled with oil from the factory.
1. Before starting, ensure that no electrical apparatus has been connected.
2. Turn the fuel cap vent lever to the on position (Fig.G).
3. Turn the engine switch to the on position (Fig. H).
4. To start a cold engine move the choke lever to the start position. In order to restart a
warm engine, leave the choke lever in the run position (Fig. I).
5. Slowly pull the recoil starter (6) until you feel it engage and then pull it briskly.
Return the recoil starter gently and slowly to the original position by hand.
NOTE: When the motor is started for the very first time, it will require a number of
attempts to start until the fuel has traveled from the tank to the motor.
6. If the choke lever was on the start position gradually move it to the run position as the
engine warms up (Fig. K).
Figure G. Figure H.
Figure I. Figure K.

page 8 Genquip Gi2000 Digital Inverter Petrol Generator
Periodic
Maintenance
Spark Plug 1. Clean Adjust
2. Replace 12
Valve Clearance Check Adjust ✔
Engine Oil 1. Check
2. Replace 12* 2* * *
Air Cleaner 1. Check
2. Replace 11 2
Fuel Filter Replace ✔
Clean Spark
Arrester-Screen ✔
Recoil Starter Check operation ✔
Choke Handle Check operation ✔
Fuel System Check hose condition
look for leaks ✔✔
Fittings Fasteners Check and Tighten ✔✔
Cooling System (Air) Check for obstructions ✔✔
Exhaust System Check for obstructions ✔
Item
* First 20 hours & then every 50 hours
Attention
1 Month or 20 hours
Pre-operation (Daily)
3 Months or 50 hours
6 Months or 100 hours
12 Months or 300 hours

page 9Genquip Gi2000 Digital Inverter Petrol Generator
Spark Plugs
1. Loosen 4 handle screw (Fig. Q) and remove handle (Fig. R).
2. Remove spark plug maintenance cover from the generator housing (Fig. S).
3. Remove the spark plug lead (Fig. T).
4. Remove any dirt from around the spark plug base.
5. With the spark plug wrench provided remove the spark plug (Fig. U).
6. Visually inspect the spark plug. Remove carbon deposits using a wire brush.
7. Check for discolouration of the top of the spark plug.
The standard colour should be tan colour.
8. Check the spark plug gap (Fig. V).
Acceptable gap should be between 0.6mm - 0.7mm.
9. Install / Reinstall the spark plug carefully by hand.
10. Once the spark plug has been seated tighten with the spark plug wrench.
11. Reinstall the spark plug cap on top of the spark plug.
12. Reinstall the spark plug maintenance cover (Fig. S) the handles and 4 handle screws.
The recommended spark plugs are as follows : NGK CR7HSA
0.6mm
to
0.7mm
Figure Q.
Figure T.
Figure R. Figure S.
Figure U. Figure V.

page 10 Genquip Gi2000 Digital Inverter Petrol Generator
Engine Oil Replacement
1. Place the generator on a level surface and warm up the engine for several minutes.
Then stop the engine.
2. Loosen the side maintenance cover screw and remove the side maintenance cover.
3. Remove the oil filler cap.
4. Drain dirty oil into a container thoroughly by tilting the engine toward the oil filler neck.
5. Once emptied, tilt the generator back up and place into the generator up right position.
6. Refill with recommended oil. Fill to the upper limit of the filler neck (Fig. W).
NOTE: The recommended 4 stroke engine oil is 10W30 (multi viscosity) 4 stroke oil.
CAUTION: Check that no foreign material, debris, dust
enters the crankcase.
7. Reinstall the oil filler cap.
CAUTION: Be sure to install securely to prevent from
falling off during operation.
8. Reinstall the side maintenance cover and tighten the cover screw.
Oil Filler
Cap
Full Oil
Level
Low Oil
Level
Figure W.