GRAND EFFECTS FBBRPCON30 Manuale utente

H0665600 REV A
OPERATION AND
MAINTENANCE MANUAL
WARNING
IF THESE INSTRUCTIONS ARE NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT,
CAUSING PROPERTY DAMAGE, PERSONAL
INJURY, OR DEATH.
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment
by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or
local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation
and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all
warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property
damage, personal injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which can
cause serious injury, property damage, or death. For installations in the vicinity of occupied/living spaces, as an additional measure
of safety, Zodiac Pool Systems LLC strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this
appliance and in any adjacent occupied spaces. Improper installation and/or operation may void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Immediately switch off main gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Grand Effects®
Fire Bowls and Inserts Premium Line
Automated Operation

Page 2 Fire Bowls and Inserts Premium Line
Automated Operation
Table of Contents
Section 1. Important Safety Instructions....... 3
Section 2. General Description ...................... 4
2.1 Product Overview..........................................................4
2.2 Product Contents...........................................................4
Section 3. Installing the Grand Effects®
Fire Bowls ...................................... 5
3.1 Preparing the Fire Bowl for Installation .........................5
3.2 Gas and Electric Requirements.....................................7
3.3 Installing the Fire Bowl ..................................................8
Section 4. Burner Setup and Adjustment .... 15
4.1 Burner Setup ...............................................................15
4.2 Burner Adjustment.......................................................16
Section 5. Maintenance ................................. 18
Section 6. Operation...................................... 19
6.1 Operating Instructions .................................................19
Section 7. Troubleshooting........................... 20
Section 8. Control Module Diagram ............. 22
Section 9. Wiring Diagram ............................ 23

Fire Bowls and Inserts Premium Line
Automated Operation Page 3
Section 1. Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK
OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
When installing and using this electrical equipment, basic safety
precautions should always be followed, including the following:
WARNING
Before installing this fire bowl, read and follow all warning notices and
instructions accompanying this bowl. Failure to follow safety warnings
and instructions can result in severe injury, death, or property damage.
Visit www.zodiacpoolsystems.com for additional free copies of these
instructions or call Zodiac Technical Support at 800.822.7933 (U.S.) or
Grand Effects at 949.697.5270
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This fire
bowl must be installed by a licensed or certified electrician in accordance
with the National Electrical Code®and applicable local codes and
ordinances. In Canada, the Canadian Electrical Code and all applicable
local codes and ordinances must be adhered to. Improper installation
will create an electrical hazard, which could result in death or serious
injury to pool or spa users, installers, or others due to electrical shock,
and may also cause damage to property. Read and follow the specific
instructions below.
SAVE THESE INSTRUCTIONS
ATTENTION INSTALLER
This manual contains important information about the installation,
operation and safe use of this product. This information should be given
to the owner/operator of this equipment.
WARNING
This unit is for outdoor use only.
Recommended CSA/AGA Clearances: Sides 4 ft / Top 6 ft

Page 4 Fire Bowls and Inserts Premium Line
Automated Operation
Section 2. General Description
2.1 Product Overview
This manual provides instructions for installing and replacing the
Grand Effects®Fire Bowls and Inserts.
CAUTION
The Grand Effects Fire Bowls are not serviceable and therefore contain
no serviceable parts. In order to prevent risk of property damage and/
or injury, no service should be attempted to the bowl in the event of
a malfunction. The Fire Box Burner Assembly must be sent back to
a Grand Effects service center for repair. A certied gas professional
should remove and re-install the Fire Box Burner Assembly.
2.2 Product Contents
1
2
3
5
4
1. Grand Effects Fire Bowl Qty 1
2. Mounting Bracket Qty 1
3. Support Plate Qty 1
4. Burner Assembly Qty 1
5. Grand Effects Fire and Water Bowl Automated
Operation and Maintenance Manual Qty 1
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, which
could result in serious injury or death. The Grand Effects Fire Bowls
are only available for 12-volt AC power. For supply connection, use only
an isolating low voltage power supply with ungrounded output, evaluated
and listed by a Nationally Recognized Testing Laboratory (NRTL) for
swimming pool use.

Fire Bowls and Inserts Premium Line
Automated Operation Page 5
Section 3. Installing the Grand Effects®
Fire Bowls
WARNING
Risk of Electrical Shock or Electrocution. This fire bowl must
be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code®(Canadian
Electrical Code, in Canada) and all applicable local codes and
ordinances. Improper installation will create an electrical hazard, which
could result in death or serious injury to pool or spa users, installers or
others due to electrical shock, and may also cause damage to property.
Always disconnect the power to the bowl at the circuit breaker before
installing or servicing the bowl. Failure to do so could result in death or
serious injury to serviceman, pool or spa users or others due to electrical
shock.
3.1 Preparing the Fire Bowl for Installation
NOTE: The installer must complete preparatory steps before re bowl is
installed.
The National Electrical Code (NEC®) allows listed low-voltage gas fired-
luminaires, decorative fireplaces, fire pits, and similar equipment using low
voltage ignitors that do not require grounding, and are supplied by a listed
transformer / power supply with outputs that do not exceed the low-voltage
contact limit (15 V RMS ac, 30 V continuous dc) to be permitted to be
located less than 1.5 m (5 ft) from the inside walls of the pool.
Metallic equipment, including metallic gas piping, shall be bonded in
accordance with the National Electrical Code in the US, and Canadian
Electrical Code in Canada.
BONDING
In the United States the National Electrical Code® (NEC®) and in Canada
the Canadian Electrical Code (CEC), require that all metallic components
of a pool structure, including reinforcing steel, metal fittings and above
ground components be bonded together (forming an equipotential bonding
grid) with a solid copper conductor not smaller than an 8 AWG (6 AWG in
Canada).

Page 6 Fire Bowls and Inserts Premium Line
Automated Operation
Additionally, Zodiac Pool Systems LLC, requires that as required by Article
680 of the NEC, the appliance be properly connected to an equipotential
bonding grid/loop that includes all electrical equipment in the system and
on the equipment pad. Bonding lugs must be connected with a solid copper
wire at least 8 AWG (6 AWG in Canada) or larger. Failure to do so may void
the Zodiac Pool Systems LLC warranty.
CAUTION
To prevent premature failure of the appliance resulting from stray
voltages and voltage differentials, the metal bowl and burner must be
bonded to other equipment which is part of the pool plumbing system
with a solid copper wire not smaller in diameter than 8 AWG (6 AWG in
Canada).
BONDING A METAL BOWL (COPPER OR ALUMINUM)
NOTE: A bonding lug is not provided for the bowl. These steps only apply
to metal bowls.
1. Attach the mounting bracket to the surface/oor. See Figure 7.
2. Wrap with copper bonding wire around a securing bolt between
the clamp ring and washer. See Figure 1 for mounting bracket
components.
3. Slide the clamp ring onto the securing bolts of the mounting bracket.
The clamp ring, washer and nut are placed inside of the bowl to secure
the bowl and bonding wire to the mounting bracket.
Clamp Ring
Mounting
Bracket
Washer
Nut
Securing
Bolt
NOTE:
Wrap bonding wire around a securing
bolt between clamp ring and washer.
Clamp ring, washer and nut to be placed
inside bowl to anchor to mounting bracket.
Anchor Bolt
Hole (3) Spacer
Figure 1. Mounting Bracket Components for Securing and
Bonding of Bowl

Fire Bowls and Inserts Premium Line
Automated Operation Page 7
BONDING THE BURNER
NOTE: The Burner insert contains a bonding lug under the bottom of the
burner. See Figure 2.
1. Loosen the setscrew.
2. Insert the bond wire into the hole.
3. Tighten the setscrew until the bond wire is secured into place.
Bonding Lug /
Bond Wire Insert
Setscrew
Figure 2. Bonding Lug on Burner Assembly
3.2 Gas and Electric Requirements
Input Voltage 120 VAC / 60 Hz to Grand Effects®Control
Panel
Output Voltage 12 VAC
Gas Type Natural Propane
Gas Pressure (Nominal) 7” wc 11” wc
Gas Flow
1 Bowl System 60,000 - 80,000 btu/hr
2 Bowl System 120,000 - 160,000 btu/
hr
3 Bowl System 180,000 - 240,000 btu/
hr
4 Bowl System 240,000 - 320,000 btu/
hr
Note: Check with your gas supplier to verify gas ows and pressures
available at the location of your installation. In many cases utility
companies will install larger meters at no charge to accommodate
larger ows.

Page 8 Fire Bowls and Inserts Premium Line
Automated Operation
3.3 Installing the Fire Bowl
WARNING
Do not install near any combustibles such as wood structures,
fuels, clothing, fabrics, or dry vegetation.
Keep surrounding area clear of all debris such as paper, leaves,
pine-needles and other combustible materials.
WARNING
This unit is for outdoor use only.
Recommended CSA/AGA Clearances: Sides 4 ft / Top 6 ft
A LP gas regulator should never be installed in the fire bowl. It should be
installed by a gas expert in a remote location away from the heat source.
Install bowls out of the way of pedestrian traffic.
Installation shall be performed by a licensed contractor. All aspects of
installation must conform to local or national codes, or in the absence of
codes, with Natural Fuel Gas Code NFPA®54 / ANSI Z223.1.
The control panel and approved gas valve must be located where they can
be easily accessible so that the gas can be shut off quickly in case of an
emergency.
1. Install the control panel and gas piping as shown in Figure 3: Natural
Gas, Figure 4: Propane Gas, or Figure 5: Commercial Installation. Gas
lines must be clean and free from any dirt, debris, or contamination.
Note: Propane piping is different than natural gas piping (shown in
Figure 3 and Figure 4).
2. The gas piping must be installed underground between the control
panel and each re or water bowl, as shown in Figures 3 and 4.

Fire Bowls and Inserts Premium Line
Automated Operation Page 9
GAS INLET
CONNECTION
MANUAL GAS
VALVE
120 VAC 60HZ INPUT
TO CONTROL PANEL
CONTROL PANEL
(TYPICALLY MOUNTED WITH
POOL EQUIPMENT UP TO 150 FEET
FROM BURNER)
12 VAC & CONDUIT (UNDERGROUND)
3/4” GAS PIPING (UNDERGROUND)
12 VAC & CONDUIT (UNDERGROUND)
BOWL #1
BOWL #2
3/4” GAS PIPING (UNDERGROUND)
GAS OUTLET
Figure 3. Natural Gas
CONTROL PANEL
(TYPICALLY MOUNTED WITH
POOL EQUIPMENT)
GAS INLET
(PROPANE)
GAS
OUTLET
12 VAC & CONDUIT (UNDERGROUND)
3/4” GAS PIPING (UNDERGROUND)
12 VAC & CONDUIT (UNDERGROUND)
BOWL #1
BOWL #2
3/4” GAS PIPING (UNDERGROUND)
GAS OUTLET
PROPANE ADDER
SUPPLIED BY GRAND EFFECTS
120 VAC 60HZ INPUT
TO CONTROL PANEL
MANUAL GAS
VALVE
JUNCTION BOX
12 VAC
12 VAC
Figure 4. Propane Gas

Page 10 Fire Bowls and Inserts Premium Line
Automated Operation
CONTROL PANEL
(TYPICALLY MOUNTED WITH
POOL EQUIPMENT UP TO 150 FEET
AWAY FROM BURNER)
GAS INLET
GAS
OUTLET
12 VAC & CONDUIT (UNDERGROUND)
3/4” GAS PIPING (UNDERGROUND)
COMMERCIAL SAFETY PIPE TRAIN
SUPPLIED BY GRAND EFFECTS
(INSTALL AS CLOSE AS POSSIBLE
TO FIRE PIT)
120 VAC 60HZ INPUT
TO CONTROL PANEL
MANUAL GAS
VALVE
JUNCTION BOX
12 VAC
12 VAC
GAS OUTLET
12 VAC & CONDUIT (UNDERGROUND)
BOWL #1
BOWL #2
3/4” GAS PIPING (UNDERGROUND)
KEYED SWITCH
KILL SWITCH
12 VAC 60 HZ INPUT DETAILS
Figure 5. Commercial Installation
3. The piping must be reduced to ½″ NPT or larger at each bowl, as
shown in Figure 6.
4. At each bowl, install a 90° gas pipe elbow on the gas line for proper
installation of a gas hose. Do not kink or make a tight radius bend on
the gas hose.
Note: The gas and electrical connection at each bowl must be located
at the center of each bowl. The connections must be installed as
shown in Figure 7.
3/4” GAS PIPING
(UNDERGROUND)
12 VAC ELECTRICAL
(UNDERGROUND)
+
G2-3/4”
MAX.
APPROX. 8-10”
WIRE LENGTH
1-1/2” MAX.
1” MIN.
1/2” KEY VALVE
WALL OR
PILASTER
PLUG OR CAP TO
KEEP WATER OUT
GAS AND ELECTRICAL
CENTERED IN COLUMN
Figure 6. Piping
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali GRAND EFFECTS Camino esterno

GRAND EFFECTS
GRAND EFFECTS 100-M Manuale utente

GRAND EFFECTS
GRAND EFFECTS 48" Essex Istruzioni operative

GRAND EFFECTS
GRAND EFFECTS FPIAUT24 Manuale utente

GRAND EFFECTS
GRAND EFFECTS FPGCORCOP40 Manuale utente

GRAND EFFECTS
GRAND EFFECTS 100 Manuale utente

GRAND EFFECTS
GRAND EFFECTS 42" Biltmore Istruzioni operative