Gree XK-19 Manuale utente

Change for life
Thank you for choosing Commercial Air Conditioners, please read this
owner’s manual carefully before operation and retain it for future reference.
Wired Remote Controller XK19 and
Wireless Remote Controller YT1F
Commercial Air Conditioners
Owner's Manual

User Notice
◆Never install the wired remote controller in the moist circumstance or expose it directly under
the sunlight.
◆Never beat, throw, and frequently disassemble the wired remote controller and the wireless
remote controller.
◆Never operate the wired remote controller and the wireless remote controller with wet hands.
Please read the manual carefully before using and installing this product.

Contents
ⅠWired Remote Controller XK19...................................................................... 1
1 Symbols on LCD ........................................................................................... 1
1.1 Outside View of the Wired Remote Controller ...................................................... 1
1.2 LCD of the Wired Remote Controller .................................................................... 1
2 Buttons ......................................................................................................... 2
2.1 Buttons on the Wired Remote Controller .............................................................. 2
2.2 Function of the Buttons ......................................................................................... 3
3 Operation Instructions ................................................................................... 3
3.1 On/Off ................................................................................................................... 3
3.2 Mode Setting......................................................................................................... 4
3.3 Temperature Setting.............................................................................................. 4
3.4 Fan Setting............................................................................................................ 4
3.5 Timer Setting......................................................................................................... 5
3.6 Swing Setting ........................................................................................................ 6
3.7 Sleep Setting......................................................................................................... 7
3.8 Turbo Setting......................................................................................................... 8
3.9 E-heater Setting .................................................................................................... 9
3.10 Blow Setting ...................................................................................................... 10
3.11 Other Functions................................................................................................. 11
4 Installation and Dismantlement .................................................................. 11
4.1 Connection of the Signal Line of the Wired Remote Controller .......................... 11
4.2 Installation of the Wired Remote Controller ........................................................ 11
4.3 Dismantlement of the Wired Remote Controller ................................................. 13
5 Errors Display.............................................................................................. 13
ⅡWireless Remote Controller YT1F ............................................................... 15
1 Function of Press Buttons .......................................................................... 15
2 Guide for General Operation ...................................................................... 17
3 Guide for Optional Operation ..................................................................... 18

Wired Remote Controller XK19
1
ⅠWired Remote Controller XK19
1 Symbols on LCD
1.1 Outside View of the Wired Remote Controller
Enter/cancel
Enter/Cancel Fan Mode
Function Timer On/Off
SHIELD
MEMORY
MASTER
SAVE
BLOW
QUIET
CO
2
AUTO TURBO SET
HOUR
F
E-HEATER
A
U
T
O
Fig.1 Outside View of the Wired Remote Controller
1.2 LCD of the Wired Remote Controller
SHIELD
MEMORY
MASTER
SAVE
BLOW
QUIET
CO
2
AUTOT URBO SET
HOUR
F
E-HEATER
A
U
T
O
12 3
4
5
6
78910 1211 13 14 15 16 17 18 19
Fig.2 LCD of the Wired Remote Controller

Wired Remote Controller XK19
2
Table 1
No. Symbols Description
1 Swing function.
2 Sleep function (Only sleep 1).
3 Running modes of the indoor unit (Cooling, Dry, Fan and Heating).
4 Defrosting function for the outdoor unit.
5 Gate-control function (this function is yet unavailable for this unit).
6 Lock function.
7 High, middle, low or auto fan speed of the indoor unit.
8Shield functions (buttons, temperature, On/Off or Mode is shielded
by the remote monitor.
9 Turbo function.
10 Memory function (The indoor unit resumes the original setting state
after power failure and then power recovery).
11 Master wired remote controller (this function is yet unavailable for
this unit).
12 It blinks under on state of the unit without operation of any button.
13 Energy-saving function (this function is yet unavailable for this unit).
14 Ambient/preset temperature value.
15 Electric auxiliary heating function.
16 Blow function.
17 Timing value.
18 Quiet function (two types: quiet and auto quiet)
(this function is yet unavailable for this unit).
19 SET It will be displayed under the debugging mode.
2 Buttons
2.1 Buttons on the Wired Remote Controller
Enter/cancel
Enter/Cancel Fan Mode
Function Timer On/Off
12 3 4
5678
Fig. 3 Buttons on the Wired Remote Controller

Wired Remote Controller XK19
3
2.2 Function of the Buttons
Table 2
No. Name Function
1 Enter/Cancel Function selection and cancellation.
2▲①Running temperature setting of the indoor unit, range:16 ~30℃.
②Timer setting, range:0.5-24 hr.
6▼
3 Fan Setting of the high/middle/low/auto fan speed.
4 Mode Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
5 Function Switchover among the functions of Turbo/Save/E-heater/Blow etc..
7 Timer Timer setting.
8 On/Off Turn on/off the indoor unit.
4+2 ▲+Mode
Press them for 5s under off state of the unit to Enter/Cancel the Memory
function(If memory is set, indoor unit after power failure and then power
recovery willresume the original setting state. If not, the indoor unit is
defaulted to be off after power recovery. Memory off is default before
delivery.).
3
+6 Fan+▼
By pressing them at the same time under off state of the unit, will be
displayed on the wired remote controller for the cooling only unit, while
will be displayed on the wired remote controller for the cooling and heating
unit.
2
+6 ▲+▼
Upon startup of the unit without malfunction or under off state of the
unit,press them at the same time for 5s to enter the lock state, in which
case, any other buttons won’t respond the press. Repress them for 5s to
quit this state.
4+6 Mode+▼ Under OFF state, the Celsius and Fahrenheit scales can be switched by
pressing “Mode” and “▼” for ve seconds.
5+7 Function+Timer
Under OFF state, it is available to go to the commissioning status by
pressing “Function” and “Timer” for ve seconds, and let “00” displayed on
the temperature display area by pressing “Mode”, then adjust the options
which is shown on the timer area by pressing “▲” and “▼”. There are totally
four options, as follows:
①Indoor ambient temperature is sensed by the return air temperature
sensor ( 01 displayed on the timer area).
②Indoor ambient temperature is sensed by the wired controller (02
displayed on the timer area).
③The return air temperature sensor is selected under the cooling, dry, or
fan mode; while the wired controller temperature sensor is selected under
the heating or auto mode. (03 is displayed on the timer area).
④The wired controller temperature sensor is selected under the cooling,
dry, or fan mode; while the return air temperature sensor is selected under
the heating mode. (04 is displayed on the timer display area).
5+7 Function+Timer
Under OFF state, it is available to go to the commissioning status by
pressing “Function” and “Timer” for five seconds. Press “Mode” button to
until “01” icon is shown at the temperature display area. The setting status
will be shown at timer area. Press “▲” and “▼” button to adjust and two
options are available: ① Three low levels (01) ; ② Three high levels (02).

Wired Remote Controller XK19
4
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit and turn it off by another press.
Note: The state shown in Fig.4 indicates the “Off” state of the unit after power on. The state
shown in Fig.5 indicates the “On” state of the unit after power on.
Fig. 4 “Off” State Fig. 5 “On” State
3.2 Mode Setting
Under the “On” state of the unit, press Mode to switch the operation modes as the following
sequence:Auto-Cooling-Dry-Fan-Heating.
Auto Cooling Dry Fan Heating
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If press either of them continuously,
the temperature will be increased or decreased by 1℃every 0.5s,as shown in Fig.6.
In the Cooling, Dry, Fan or Heating mode, the temperature setting range is 16℃~ 30℃ .
In the Auto mode, the setting temperature is unadjustable.

Wired Remote Controller XK19
5
Fig.6
3.4 Fan Setting
Under the “On”/”Off” state of the unit, press Fan and then fan speed of the indoor unit will
change circularly as shown in Fig.7.
Low Middle High
Enter/Cancel Fan Mode
Function
Timer On/Off
AUTO
Fig.7
3.5 Timer Setting
Under the “On”/”Off” state of the unit, press Timer to set timer off/on.
Timer on setting: press Timer, and then LCD will display “xx.x hour”, with “hour” blinking. In this
case, press ▲or ▼ to adjust the timing value. Then press Enter/Cancel to conrm the setting.
Timer off setting: press Timer, if LCD won’t display xx.x hour, and then it means the timer
setting is canceled.
Timer off setting under the “On” state of the unit is shown as Fig.8.

Wired Remote Controller XK19
6
Fig. 8 Timer off Setting under the “On” State of the Unit
Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by
0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every
0.5s.

Wired Remote Controller XK19
7
3.6 Swing Setting
Swing On: Press Function under on state of the unit to activate the swing function. In this case,
will blink. After that, press Enter/Cancel to make a conrmation.
Swing Off: When the Swing function is on, press Function to enter the Swing setting interface,
with blinking. After that, press Enter/Cancel to cancel this function.
Swing setting is shown as Fig.9.
Fig. 9 Swing Setting
Note:
① .
Sleep, Turbo or Blow setting is the same as the Swing setting.
② .
After the setting has been done, it has to press the key “Enter/Cancel” to back to the setting
status or quit automatically ve seconds later.
Altri manuali per XK-19
3
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue:
Altri manuali Gree Controllori

Gree
Gree CE52-24/F(C) Manuale utente

Gree
Gree XE71-42/G Manuale utente

Gree
Gree XE70-13/E Manuale utente

Gree
Gree XK55 Manuale utente

Gree
Gree XK49 Manuale utente

Gree
Gree XE70-33/H Manuale utente

Gree
Gree XK60 Manuale utente

Gree
Gree XK60 Manuale utente

Gree
Gree XK76 Manuale utente

Gree
Gree CE54-24/F(C) Manuale utente

Gree
Gree XE7A-24/H Manuale utente

Gree
Gree XK86 Manuale utente

Gree
Gree LE60-13/C1 Manuale utente

Gree
Gree CE53-24/F(C) Manuale utente

Gree
Gree ME20-24/D1(T) Manuale utente

Gree
Gree CE53-24/F(C) Manuale utente

Gree
Gree XK-19 Manuale utente

Gree
Gree CE55-24/F Manuale utente

Gree
Gree XK46 Manuale utente

Gree
Gree XK46 Manuale utente





















