Grozone Control LS8 Manuale utente

USER GUIDE
LS8/sLS8
Light Switcher/Smart Light Switcher
www.grozonecontrol.com

TABLE OF CONTENTS
WARNINGS & CAUTION.............................................................1
LS8/SLS8 GENERAL DESCRIPTION...............................................2
SPECIFICATIONS ........................................................................3
INSTALLATION GUIDE..............................................................4-5
TROUBLESHOOTING…………………………….………………...……..……..6-
WARRANTY & CUSTOMER SERVICE ……………………….……..……...8-9

•
This product must be installed by a Licensed electrician only
•
Read all instructions before operating the LS8/sLS8
•
This light switcher is designed to work with electronic and
magnetic ballasts
•
Protect your LS8/sLS8 against water or any sprayed products
•
Mount your LS8/sLS8 securely to the wall using included hardware
•
Do not attempt to repair the LS8/sLS8 yourself call Grozone
Control technical support 855-262-1800
•
Make sure to verify your electrical panel components and capacity
prior to wiring your LS8/sLS8 into the power source
•
Plug in 240 V loads only
FOR SUPPLY CONNECTIONS, USE 8 AWG OR LARGE WIRES SUITABLE
FOR AT LEAST 75°C (167°F). USE COPPER WIRE ONLY.
1
WARNING & CAUTIONS

The LS8 Light Switcher is specifically designed to operate a high intensity
discharge (HID) lighting systems. The system can handle up to a maximum of
eight (8) 1000 watt HID metal halide (MH) or high pressure sodium (HPS) grow
lights. The activation of the internal power switches (relays) is performed
through 120V trigger inputs. The LS8 can activate 8 lights with one single trigger
input or two 4-light zones using two trigger inputs with LS8 Dual Zone. This
light switcher provides up to 40 amps of capacity on a standard 240 volts
circuit. There is a 120V service outlet (max 10A); this is intended to use with a
ventilation fan light movers timers or any other accessory. The LS8 is built with
only the highest quality components and will provide you with years of trouble
free performance.
The sLS8 integrates a high temperature shut-off function that turns off 1 2
or 3 of the 4 zones if room temperature goes above the preset temperature
limit. sLS8 provides a remote temperature sensor and a PCB-mount slide
switch to set temperature limits. Refer to page 5 for more information.
2
LS8 / sLS8 GENERAL DESCRIPTION

LS8
•
Number of lights : 8 lights single zone or dual zone model.
•
Number of 120V trigger inputs: 1 for single 8-light zone. Second trigger input
to control two 4-light zones separately with dual zone model.
sLS8:
•
Number of lights : total of 8 lights 4 zones of 2 lights.
•
Number of 120V trigger input: 1
COMMON SPECIFICATIONS
•
Light receptacles: NEMA 6-
15 (240V 15A) 4 duplex receptacles for 8 lights
4 lights on each side.
•
Service receptacle: NEMA 5-15 (120V 10A).
•
Metal enclosure dimensions: 14 in. X 10.5 in. X 2.5 in. (H x W x D)
•
Circuit breakers: total of 4 double breakers (240V 15A) 1 double breaker
for two lights. Breakers meet UL 489.
•
Input power requirement: 240V 40A 60Hz.
SPECIFICATIONS
3

IMPORTANT: THIS PRODUCT MUST BE INSTALLED BY A
LICENSED ELECTRICIAN ONLY
1. Unscrew the 4 cover screws.
2. Secure the LS8/sLS8 to the wall using the included hardware (#8 wood screws
in keyhole shaped mounting holes).
3. Use the correct size wire for your application. Please check local electrical
codes for wire size requirements. Carefully strip the 2 power wires
approximately 1’’. Pass the stripped and copper wires through the largest
strain relief located on bottom wall of enclosure.
Hook up 240V wires as follows:
•
Black wire to JP5 connector L1
•
Red or White wire to the
JP5 connector L2
•
Copper wire to GROUND LOG located
on bottom wall of enclosure next to
metallic wire connectors.
IMPORTANT NOTICE:
2 POWER CONNECTOR models are available - follow instructions accordingly.
Gray Spring Terminal (shown below): insert small flat screwdriver at 45°
into
square hole pry tool downward to open contact insert appropriate wire then
release tool. Tighten up wire connectors (strain relief).
Black Screw Terminal (not shown): loosen terminal screws insert appropriate
wire under screw plate then tighten up screws and wire connectors
(strain relief).
INSTALLATION GUIDE
4

4. sLS8 ONLY:
Set high temperature limits by sliding the switch to preferred preset values.
sLS8 provides 3 different settings:
•
Setting 1: high temperature function is disabled
then sLS8 works as a LS8.
•
Setting 2:
- Limit to turn 1st zone OFF: 27°C / 80°F
- Limit to turn 2nd zone OFF: 28.5°C / 83°F
- Limit to turn 3rd zone OFF: 30°C / 86°F
•
Setting 3:
- Limit to turn 1st zone OFF: 30°C / 86°F
- Limit to turn 2nd zone OFF: 31.5°C / 89°F
- Limit to turn 3rd zone OFF: 33°C / 92°F
sLS8 High Temperature Shut-Off Operation :
In order to maintain the room temperature below the preset temperature limits the
sLS8 may need to turn off 1 2 or 3 zones each zone comprising 2 lights. To ensure an
even distribution of the light in your grow room the sLS8 features smart zone rotation
that changes the OFF zone(s) from zone 1 to zone 4 alternately.
Preset high temperature limits are made up of 3 values:
•
When room temperature reaches the 1st value only 1 zone will turn off.
•
If room temperature reaches the 2nd value a second zone will turn off.
•
Finally if room temperature reaches the 3rd value a third zone will turn off.
NOTE : when a high temp condition is met turning 1 zone OFF should enable room
temperature to return to normal condition. Turning 2 or 3 zones OFF may occur when
cooling equipment or outdoor temperature reach extreme conditions. In the worst
case (3 zones OFF) there will always be a minimum of 1 zone with its lights ON to
maintain the photoperiod in your grow room.
Replace cover and tighten up screws.
Do not over tighten to prevent stripping screw threads.
5
.
INSTALLATION GUIDE
5
Maximum OFF period: the zone rotation function ensures that OFF periods never
exceed 1 hour per zone.
Minimum OFF period: to prevent hot start OFF periods last a minimum of 20
minutes even though room temperature has cooled down below limits in less than
20 minutes.

Problems Actions
The lights will not turn on
Verify that there is power to the 120V
trigger input. You will hear a loud
“click” caused by relay switching when
power is applied to the trigger input.
Check if the main circuit breaker and
the LS8/sLS8 breakers are in the ON
position and reset them if necessary.
Verify that the unit is wired properly.
Check with a licensed electrician if
there are any concerns regarding
proper installation of your LS8/sLS8
put the switch in position #1.
There is no power on one side of your
LS8/sLS8
(A and B zones on the left side
C and D zones on the right side)
Check if the corresponding LS8/sLS8
breakers have tripped. The breaker
actuator must be firmly engaged in the
ON position (UP).
sLS8 put the switch in position #1.
LS8 Dual Zone check if both of your
trigger cord are properly plug in the
wall.
TROUBLESHOOTING
6

Problems Actions
The main circuit breaker keeps
tripping.
Check the main circuit breaker in the
electrical panel the breaker value must
be at least 50A to meet most of
North-American electrical codes.
Please consult with a licensed
electrician.
Still having problem with your LS8/sLS8?
Please contact Grozone Control Technical Support at
855-262-1800 or by email service@grozonecontrol.com
TROUBLESHOOTING

DO YOU HAVE A PROBLEM WITH YOUR LS8/sLS8 ?
PLEASE READ THESE
INSTRUCTIONS CAREFULLYAND SAVE THEM FOR FUTURE REFERENCE
1. I think my LS8/sLS8 is damaged, or it simply does not work as indicated
in the user guide, what should I do?
•
Please refer to the troubleshooting steps. Follow these instructions carefully
step by step. The LS8/sLS8 should work as described in the “Actions” column
of the Complete Troubleshooting Guide.
Do you need assistance on executing the Troubleshooting steps?
1. Contact us at 1-855-262-1800
2. Send us an EMAIL at service@grozonecontrol.com or
3. VISIT our Technical Support Center at www.grozonecontrol.com/
techsupport.html
Technical Support is available Monday through Friday, from 8:00 AM to 8:00 PM,
Eastern Time.
WARRANTY & CUSTOMER SERVICE
8
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue:
Altri manuali Grozone Control Interruttore