GSS STI 1932 CT Manuale utente

Assembly Instruction
STI 1932 CT
Default access data:
192.168.0.120
User: admin
Password: geheim

- 2 - STI 1932 CT
Contents
1 Safety regulations and notes ........................................................................4
2 General information ....................................................................................6
2.1 Packing contents ............................................................................6
2.2 Meaning of the symbols used ..........................................................6
2.3 Technical data ...............................................................................6
2.4 Description ...................................................................................7
General ........................................................................................7
User .............................................................................................9
Administrator access .................................................................9
Guest access ............................................................................9
3 Assembly ..................................................................................................10
3.1 Device overview ..........................................................................10
3.2 Installing the device .....................................................................11
3.3 Potential equalisation (PE) .............................................................12
3.4 Connecting the device ..................................................................12
3.5 Changing a Power Module ...........................................................13
3.6 Changing a Case Fan ..................................................................14
4 Configuration / Updates ............................................................................15
4.1 Initial configuration ......................................................................15
4.2 Configuration ..............................................................................18
Overview window .......................................................................18
Perform changes .........................................................................19
Number format............................................................................19
Configuration menus ....................................................................20
Input .....................................................................................20
Redundant Input (Software option) ............................................22
Output ..................................................................................25
Filter .....................................................................................28
NIT .......................................................................................31
LCN – Logical Channel Numbering ..........................................35
System menus .............................................................................37
Logbook ................................................................................37

- 3 - STI 1932 CT
Notification ...........................................................................38
Network ................................................................................40
OpenVPN .............................................................................41
Security .................................................................................42
- Administrator access .............................................................42
- Guest access ........................................................................42
Firmware ...............................................................................43
- Output Modulation of Head-end Station: ..................................44
- System settings: ....................................................................44
- Firmware update: .................................................................44
- Backup: ...............................................................................45
- Manager: ............................................................................45
- Reset to factory defaults: ........................................................46
- System restart: ......................................................................46
- Software Options (fee-based): ................................................46
- Ping (Network Diagnostic Tool): ..............................................47
User ......................................................................................47
5 Channel and frequency tables ....................................................................48

- 4 - STI 1932 CT
1 safety regulations and notes
• The devices meet the EU directives 2011/65/EU, 2014/30/EU and
2014/35/EU.
• This device is subject to the provisions of protection class I. Operate the
device only to mains sockets with protective conductor connection!
• If the power cords need to be replaced, only use OEM power cords.
• The standards EN/DIN EN 50083 resp. IEC/EN/DIN EN 60728 must be
observed, especially concerning equipotential bonding and earthing.
• Observe the relevant country-specific standards, regulations and guidelines
on the installation and operation of antenna systems.
• Before starting installation or service work disconnect the receiving system
from mains.
• Do not perform installation and service work during thunderstorms.
• Assembly, installation and servicing must be carried out by an authorised
electrician.
• Caution! Dangerous voltage! For a complete disconnection from the mains,
both mains plugs must be pulled out of the mains sockets. Ensure that the
mains plugs can be pulled out without difficulties.
• The head-end station should only be installed in a room where the permis-
sible ambient temperature range (0 °C … +50 °C ) can be maintained, even
during fluctuations in climatic conditions.
• To avoid too strong interacted heating of the head-end stations it is not
admissible to mount them one upon the other without using thermic precau-
tions (e.g. permanently air recirculation, ventilation etc.).
• If additional fans are to be used to circulate the air, ensure that the system
will be shut down (disconnected from mains) should any one of the fans fail.
• Install the head-end station
- in a dry, dust-free environment, in such a manner that it is protected from
moisture, fumes, splashing water and dampness
- where it is protected from direct exposure to sunlight
- on a vibration-free wall or floor construction
- not within the immediate vicinity of heat sources
• In case of the formation of condensation wait until the system is completely
dried.
• Ensure that the head-end station is adequately ventilated.
• Do not cover the ventilation openings!
• Do not install the head end in cabinets or recesses which are not ventilated.
• Do not place any vessels containing liquids on the head-end station.

- 5 - STI 1932 CT
• Do not place anything on the head-end station which could initiate fires
(e.g. candles).
• Due to the risk of fires caused by lightning strikes, we recommend that
all mechanical parts (e.g. distributor, equipotential bonding rail, etc.) be
mounted on a non-combustible base. Wood panelling, wooden beams,
plastic covered panels and plastic panels are all examples of combustible
bases.
• Avoid short circuits!
• To ensure electromagnetic compatibility, make sure all connections are tight
and that the covers are screwed on securely.
• No liability is accepted for damage caused by faulty connections or inap-
propriate handling of the device.
• The firmware contains components which are licensed as Open Source
software. The components to which this relates and the respective license
terms can be called up via menu Help/Licences.
This parts of software source code can be provided at cost price on CD
upon request. The licensee is granted a non-exclusive right of use for the
Open Source Software by the respective right holders used; the conditions
stipulated by the respective valid license terms apply. The license terms of
this license only apply to the components which are not listed as Open
Source software.
In relation to the licensor the regulations on liability and warranty in these
license terms apply for the whole software. The liability and warranty regu-
lations of the Open Source licenses only apply in relation to the respective
right holders.
• Test the firmware versions of the device and update them if necessary. The
current firmware version can be found at "www.mygss.eu".
Take action to prevent static discharge when working on the device!
Electronic devices should never be disposed of in the household rubbish. In accordance
with directive 2002/96/EC of the European Parliament and the European Council from
January 27, 2003 which addresses old electronic and electrical devices, such devices
must be disposed of at a designated collection facility. At the end of its service life,
please take your device to one of these public collection facilities for proper disposal.

- 6 - STI 1932 CT
2 general information
2.1 PaCkin g C o nt e n t s
1 STI 1932 CT 1 LAN cable
1 Brief assembly instructions 2 Mains cable
2.2 me a n ing of th e symbol s us e d
Important note Disconnection, all power plugs
Danger by electrical shock
—> General note
• Performing works
2.3 teChn i C al data
The devices meet the following EU directives:
2011/65/EU, 2014/30/EU, 2014/35/EU
The product fulfils the guidelines and standards for CE labelling (page 49).
Unless otherwise noted all values are specified as "typical".
Input data
Over all input data rate/interface (∑ lines 1-16/17-32): .......... ≤ 800 MBit/s
Buffer memory .......................................................................60 kBit/line
(corresponds e.g. at 50 MBit/s to approx. 1 ms buffer)
IGMP ................................................................................................V2
Protocols: .......................................................... UDP (User Data Protocol),
RTP (Real-Time Transport Protocol)
RF output QAM
Frequency range: ............................................. 42.0 MHz … 868.0 MHz
Types of modulation: ..................................QAM 4, 16, 32, 64, 128, 256
Output level: ......................................................................73…89 dBμV
Dynamic phase error: ................................................................... < 0.2 °
MER: ............................................................................................45 dB
Output impedance: ......................................................................... 75 Ω
Symbol rate: ................................................................ 1000…7500 kBd

- 7 - STI 1932 CT
RF output COFDM
Frequency range: ............................................. 42.0 MHz … 868.0 MHz
Types of modulation: ........................................ QPSK, 16 QAM, 64 QAM
Transmission modes ............................................................................ 2k
Code rates ....................................................... 1/2, 2/3, 3/4, 5/6, 7/8
Guard intervals .................................................... 1/4, 1/8, 1/16, 1/32
Output level: ......................................................................73…89 dBμV
Output impedance: ......................................................................... 75 Ω
LAN interfaces for HTML control/update
Standard: ............................................................................. 100-BASE-T
Connections
LAN (for data) 1000-BASE-T: ..............................................2 RJ45 sockets
LAN (for control) 100-BASE-T: .............................................2 RJ45 sockets
RF output: .............................................................................. 1 F socket
RF test output (-25 dB): ............................................................ 1 F socket
General
Mains units: ...... 2 (redundant; can be replaced separately during operation)
Supply voltage ....................................................100…240 V, 50/60 Hz
Power consumption: .............................................................. max. 75 W
Cooling fans: .....................3 (can be replaced separately during operation)
Ambient temperature: ............................................................ 0…+50 °C
Dimensions (W x H x D): ................. 483 mm x 44.5 mm (1HU) x 490 mm
Weight: ....................................................................................... 6.2 kg
2.4 desCri P ti on
The head-end station converts 32 (2x16) MPTS streams into 32 QAM or
COFDM modulated transponders. A further 32 MPTS data streams can be
provided as redundant input signals as a software option for an extra charge.
gen e r al
The station is equipped with two LAN inputs, one RF output and one test output
(–25 dB). The MPTS input data streams of lines 1-16 are fed to the left LAN
input that the lines 17-32 at the right LAN input.

- 8 - STI 1932 CT
RF OUT
Combiner
TEST
–25dB
MPTS Stream 1
MPTS Stream 16
MPTS Stream 17
MPTS Stream 32
LAN 1
LAN 2
Modulator
"1"
Modulator
"17"
Modulator
"32"
Modulator
"16"
The configuration of the station is to be done via an HTML user interface via a
PC and a standard HTML browser connected to the configuration input
(Con-
trol)
.
The two configuration inputs are connected via an internal switch. Several sta-
tions can thus be cascaded for configuration.
GSS
OpenVPN
Server
If the Control input is connected to
the Internet, after the initial setup,
you can get worldwide access to the
station via an OpenVPN connection
– by PC, tablet or smart phone with
Internet access.
—> When using mobile terminals – dependent on your mobile contract
– additional connection costs / data transfer costs may also be
incurred here.

- 9 - STI 1932 CT
32 LEDs provide an indication of the status of the 32 lines based on their col-
our and indicate if the respective line is switched on (LED illuminates) or off.
The LEDs are blinking red/green during data overflow.
The station is powered by two independent power supplies (redundancy). The
power supplies can be replaced individually during operation. If one power
supply unit fails, a warning signal sounds.
If the control input has connection to the Internet, the device can send a warn-
ing e-mail when a signal, power supply or one of the fans fails.
use r
adm i n is tr ato r aCCess
The user admin has access to all menus and may make changes.
—> The default password for the user admin is geheim.
gu es t aCCess
The user gast has access to (almost) all menus, but may not make any changes.
—> The default password for the user gast is gast.
A guest access is shown in all menus:
The button has no function!

- 10 - STI 1932 CT
3 assembly
3.1 de v i Ce ov e rvi e w
sw rt ge
Caution!
Dangerous
voltage!
Separate
all power
sources
8
9 10 11 12
14 15 1613 14 15 1613 1721
76431 2 5
1
9
17
25
8
16
24
32
20
1
9
17
25
8
16
24
32
5
1
MPTS input lines 1-16
2
MPTS input lines 17-32
3
Reset IP address, host name and password*
4
Alarm tone off
5
Status LEDs of lines 1…32**
6
Fan access
7
LAN socket for configuration
8
Power ON/OFF
9
GND fan connectors
10
Fan monitoring connectors
11
+12 V fan connectors
12
Fan screws
13
PSU releases
14
PSU brackets
15
IEC connectors C14; connectors for mains cables
16
PSU status LEDs***
17
Connector for potential equalisation
20 RF output 21 Test output –25dB
* Reset IP address/host name/password (hold depressed for more than 5 seconds) to
192.168.0.120/gss/geheim
**
Green = good signal; red = no signal; red/green blinking = data overflow; off = modulator off
*** Power off + no fault –> LED 16 blinks green
Power on + no fault –> LED 16 lights green
Power on + fault –> LED 16 blinks red
Indice
Altri manuali GSS Modulatore

GSS
GSS HDTV 1000 T Manuale utente

GSS
GSS HMM 470 Manuale utente

GSS
GSS STC 160 Manuale utente

GSS
GSS HMM 470 Manuale utente

GSS
GSS HDMT 1290 Manuale utente

GSS
GSS HDTA 614 T ASI Guida all'installazione

GSS
GSS HD2CT 860 C Manuale utente

GSS
GSS HDMT 1000 ASI LAN Manuale utente

GSS
GSS HDTV 1000 FM Manuale utente

GSS
GSS HDM 500 C Manuale utente

GSS
GSS HDTV 1000 TD Manuale utente

GSS
GSS STIM 1916 CT Manuale utente

GSS
GSS HDTA 614 C ASI Manuale utente

GSS
GSS HDTV 1000 ASI LAN Manuale utente

GSS
GSS HDM 660 T Manuale utente

GSS
GSS HDMU 790 C Manuale utente

GSS
GSS HDM 2380 P CI Manuale utente

GSS
GSS PMDF 1000 Manuale utente

GSS
GSS HDMC 1000 FM Manuale utente

GSS
GSS HDMT 263 Manuale utente