Technical parameters
Model (system)HP200S1 HP300S1
Tank volume 195L 293L
Rated voltage/ frequency 230V/50Hz 230V/50Hz
Tank rated pressure 0.85MPa 0.85MPa
Corrosion protection Magnesium rod(x2) Magnesium rod(x2)
Water proof grade IPX4 IPX4
Water inlet and outlet connection G3/4"F G3/4"F
Safety valve connection G3/4"F G3/4"F
Drain & Water intlet connection G3/4"F G3/4"F
Product dimension(tank unit)
544*512*1765 mm 632*600*1795 mm
Packing dimension(tank unit)
676*636*1927 mm 737*696*1958 mm
Packing dimension (external unit)
960*425*735 mm 960*425*735 mm
Net/Gross weight(tank unit)77/89kg 98/112kg
* Tested by LCIE France according to CDC LCIE N° 103-15/B:2011 +A1:2013 and EN16147:2011.
Model (tank unit)
Dimension and connections
7
English
Product dimension(external unit)
Net/Gross weight(external unit)
899*352*681 mm 899*352*681 mm
41/44kg 44/48kg
Model (external unit)
TS200HE-S1 TS300HE-S1
UE1.0-S1 UE1.5-S1
Power input by electric backup 2150W 2150W
Rated power input by heat pump 665W 885W
Maximum power input by heat pump 1000W 1350W
Maximum power input 3150W 3500W
Type of extraction Exterior Exterior
Coefficient of performance (COP) * 3.09 3.20
Tapping cycle L XL
Max volume of usable hot water at 40
℃
setting at 55
℃
245.1L 382.6L
Performance certified at 7 ° C air (CDC LCIE 103-15 / B)
Standby power input/ Pes 28W 29W
Heating up time 4h03 4h45
Reference temperature /Tref 53.86
℃
53.91
℃
Assembled System
Default temperature setting 55
℃
55
℃
Temperature setting range- with heater 35
℃
-75
℃
35
℃
-75
℃
20m 20m
Max working pressure of refrigerant 0.8/2.8MPa 0.8/2.8MPa
Refrigerant type / weight R134a/1.3kg R134a/1.5kg
Sound power level 64dB 64dB
Ambient temperature for use of product -7~45
℃
-7~45
℃
Operating temperature of heat pump -7~45
℃
-7~45
℃
Maximum length of refrigerant pipe