Hanwell IM6001 Manuale utente

hanwell.com
IM6001
Hanwell Smart Receiver 2
(SR2)
User Manual

Intentionally Blank

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
hanwell.com Page 1 of 22 IM6001 - 3
Document History
Document Number: IM6001
Issue
No. Issue Date Changes By
1 11 July 2018 First release. IR
2 23 October 2018
Addition of Appendix 3 and minor
amendments. IR
3 20 February 2019 Addition of information on IEC mains inlet
socket and voltage selection switch. IR
4 17 June 2019 Addition of Cautions, Warnings and
additional specifications. IR

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
IM6001 - 3 Page 2 of 22 hanwell.com
Contents
Document History ..............................................................................................................................1
1Introduction......................................................................................................................... 3
2Pre-Requisites..................................................................................................................... 4
2.1Inventory ..............................................................................................................................................4
2.2SR2 Unit Ratings ................................................................................................................................4
2.3SR2 Receiver Unit – External Appearance................................................................................ 5
3Copy of Document GD6014 .............................................................................................. 6
3.1Physical Pre-requisites .................................................................................................................... 6
3.1.1Virtual Pre-requisites...................................................................................................................7
4Installing the SR2 ............................................................................................................... 8
4.1Wall-mounting the SR2.................................................................................................................. 8
4.2Connecting the Receiver Unit ....................................................................................................... 9
4.3Connecting the Power and Network..........................................................................................10
4.4Configuring the SR2 Receiver’s Network Settings.................................................................. 11
5Advanced SR2 Configuration ..........................................................................................12
5.1Fall Back Operation.........................................................................................................................12
5.2On-Board Sensors ........................................................................................................................... 12
5.3Alarm Relay Operation ................................................................................................................... 12
5.4Sensor Groups.................................................................................................................................. 13
5.5Transmitter Preamble ..................................................................................................................... 13
6Additional Connections ....................................................................................................14
6.1Alarm Relays ..................................................................................................................................... 14
6.2MS1000 Control Panel.................................................................................................................... 15
6.3On Board Sensors ...........................................................................................................................15
7Maintenance ......................................................................................................................17
7.1Uninterruptable Power Supply (UPS) Battery .......................................................................... 17
7.2Coin Cell Battery.............................................................................................................................. 17
7.3Fuse Specifications ......................................................................................................................... 17
8Contact Hanwell Solutions...............................................................................................18
Appendix 1 – SR2 Connection Data.............................................................................................. 19
Appendix 2 - Setting up an SR2 with an IP Address for use with EMS or Synergy ...............20

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
hanwell.com Page 3 of 22 IM6001 - 3
1Introduction
This Document details how to install the Hanwell Smart Receiver 2 (SR2) Unit.
The SR2 is a Network Enabled Receiver, designed for collecting environmental monitoring
data from multiple points within a site. In addition, it can be upgraded to a Transceiver which
both receives and re-transmits data.
It uses the standard TCP/IP communications protocol for rapid data handling.

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
IM6001 - 3 Page 4 of 22
hanwell.com
2Pre-Requisites
Before installing and configuring the SR2, you should have read Document GD6014 Smart
Receiver Installation Pre-requisites which details the necessary pre-conditions for installation.
A copy of this is supplied in Section 3.
If a Radio Survey has not been completed, the SR2 unit should not be permanently mounted
to the wall until the radio reception has been tested for the proposed location.
2.1 Inventory
Your SR2 should be supplied with the following, as standard:
1 x SR2.
1 x 1m straight-through CAT5 cable.
IEC Power Cord with Locking System; see Figure 3 overleaf.
1 x UPS battery (unless an external one is to be used).
1 x External Receiver Unit (boxed separately).
USB-SP2; USB stick containing relevant manuals, including IM6001 (this document).
If you are missing any of these items, please contact Hanwell Solutions Ltd.; see Section 8.
You will also need the EMS application installed on your System.
2.2 SR2 Unit Ratings
Voltage:
Frequency:
Current:
Power:
115 – 240V Switchable
50 – 60Hz
180mA @230vAC
80W
WARNING!
To Avoid Possible Electric Shock or Personal Injury, Follow These Guidelines:
DO NOT operate this Unit without a properly grounded, properly polarised power cord.
DO NOT connect this Unit to a non-grounded, non-polarised outlet.
Caution
The SR2 Unit contains a Lead-Acid UPS battery which should never be left for extended
periods in a discharged state, to prevent damage to the battery’s cells.

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
hanwell.com
Page 5 of 22 IM6001 - 3
2.3 SR2 Receiver Unit – External Appearance
Figure 1 - SR2 Unit Control Panel
Figure 2 - Underside of Unit
Figure 3 - IEC Power Cord with Locking Mechanism
Locking Mechanism*
Internal Power Supply Unit (PSU) Fuse
*Note: The SR2 MUST NOT
be powered via a
standard IEC Power
Cord without a
locking mechanism.

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
IM6001 - 3 Page 6 of 22 hanwell.com
3Copy of Document GD6014
Hanwell Document GD6014 – Hanwell EMS Pre-Requisites should have been supplied when
the SR2 was ordered, so that the pre-requisites could be completed in advance. The contents
of it are reproduced here in case the original has been lost.
This Section lists the pre-requisites – physical and virtual – needed to install and configure an
SR2 for operation on a network. The required information can, in most cases, be obtained
from your IT Department.
Note: The network information must be available prior to the commissioning of the System.
3.1 Physical Pre-requisites
The following pre-requisites assume that a final location for the SR2(s) has been identified
following a Radio Survey. If this is not the case, then the following should be factored in when
deciding the SR2’s final location.
There should be:
A 24-hour mains power outlet within 1.5m of the planned location.
An enabled 10/100 Base T LAN socket at the planned location.
Note: If this is greater than 1m from the planned location, a suitable straight through
CAT5 lead is required. This can, in most cases, be supplied by your IT department.
A suitable wall structure on which the SR2 can be mounted so that the antenna is
vertical.
The planned location should NOT:
Be in an area subjected to high temperature or humidity levels.
Have any metallic objects within 0.3 metres of the antenna in any direction; this
includes any structures hidden within walls, pillars etc.

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
hanwell.com Page 7 of 22 IM6001 - 3
3.1.1 Virtual Pre-requisites
Each SR2 requires a unique Static IP address, which should be assigned by you IT
Department.
This IP address should be accessible from the PC on which the software will run.
IP Address
For example: 192.168.1.100 _ _ _ . _ _ _ . _ _ _ . _ _ _
Subnet
For example: 255.255.255.0 _ _ _ . _ _ _ . _ _ _ . _ _ _
Gateway
For example: 192.168.1.1 _ _ _ . _ _ _ . _ _ _ . _ _ _
If the IT Department requires a MAC address in order to assign an IP address, contact Hanwell
Solutions Ltd. to request it; see Section 8.
The MAC address is also listed on a label on the ‘daughter’ PCB inside the SR2’s case, in the
format xx:xx:xx:xx:xx:xx.

Hanwell Smart Receiver 2 (SR2)
Instruction Manual
IM6001 - 3 Page 8 of 22
hanwell.com
4Installing the SR2
There are four steps to installing an SR2:
1.
Wall-mounting the SR2. See Section 4.1.
2.
Connecting the Receiver Unit. See Section 4.2.
3.
Connecting the Power and Network connections to the SR2. See Section 4.3.
Caution:
DO NOT power up the SR2 until these steps have been completed!
4.
Configuring the SR2 in the EMS software. Refer to the Online EMS User Guide for details
on this:
http://www.help.emsprocloud.com/index.html?configuring-the-smart-receiver.html
In addition, you can also change the Default Hardware Settings of the SR2 (see Section
5) or connect Local Sensors (see Section 5.2).
4.1 Wall-mounting the SR2
The SR2 has a keyhole and four screw holes in is rear plate. These should be used for
wall-mounting the Unit.
Note: We recommend the radio reception at the chosen location is thoroughly tested before
final wall-mounting!
1.
Use the holes in the rear of the Unit as a drilling template to mark the position of the
required screw holes.
2.
Place the SR2 on the wall and screw into place.
Figure 4 - Rear of Unit
Indice