HARD 741-CPGP Manuale utente

DOERNBECHER
CRITICAL CARE CRIB
MODELS 741-CPGP & 752-KPGP
Revised 2022.1 1.31.2022
SERVICE MANUAL
The nations #1 manufacturer of hospital cribs

TABLE OF CONTENTS
General Information..............................................................................................................
Side Rail Operation & Safety................................................................................................
StaffControl Instructions......................................................................................................
WeighSafe Scale Operating Instructions..............................................................................
WeighSafe Scale Calibration Instructions.............................................................................
Mattress Platform Diagram...................................................................................................
Mattress Platform Parts List..................................................................................................
Side Rail Assembly & Parts List............................................................................................
Portland Gate Assembly & Parts List....................................................................................
Head & Foot End Assembly Diagram & Parts List................................................................
Slide Rod Assembly & Parts List...........................................................................................
Slide Rod or Side/End Rail Replacement Instructions..........................................................
Trigger Assembly for Rails or Johns Hopkins Handle Replacement.....................................
Trigger Replacement for Portland & Dialysis Gates..............................................................
*1904 IV Pole Diagram.........................................................................................................
*1904 IV Pole Parts List........................................................................................................
*1904 IV Pole Installation......................................................................................................
Shelf & Bumpers Parts List...................................................................................................
Shelf & Bumpers Installation or Replacement Instructions...................................................
Casters & Misc Parts List......................................................................................................
Caution & Electrical Warnings..............................................................................................
Cleaning Instructions for Cribs/Beds & Mattresses..............................................................
Preventative Maintenance Guide & Checklist.......................................................................
Warranty................................................................................................................................35
5
4
3
7
8
9
6
10
11
12
13
14
16
19
20
21
22
23
26
27
29
30
18
2

GENERAL INFORMATION
Hard Manufacturing cribs and youth beds are intended for use by patients up to 150lbs.
It is strongly recommended to discourage parents or caregivers from getting into the crib or
bed with the patient as it may cause premature wear or damage to various components.
The expected service life of all cribs and beds made by Hard Manufacturing is 9 years
when preventative maintenance guidelines are followed.
Hard Manufacturing recommends the preventative maintenance checklist found at the
end of this manual be performed at least once per year on each crib or bed in your facility.
Cribs not meeting the criteria listed on the preventative maintenance checklist should be
removed from service until they can be repaired as per the recommended guidelines.
Hard Manufacturing will support parts on our cribs and beds for up to 12 years from the
date of manufacture as long as we still make the part or can obtain it from our vendors.
Cleaning instructions for all Hard Manufacturing cribs and beds can be found at the
end of this manual. Failure to follow the proper cleaning instructions can result in
premature rust and corrosion of the parts on your cribs.
To request a quote on replacement parts- please have either the serial # from the silver
sticker located on the mattress platform, or the crib or bed model # and date of manufacture
from the sticker on the bottom left side of the foot end available. Contact info is as follows:
Parts Manager
800-873-4273 x216
receive an order confirmation within one (1) business day, please resend the order until a
confirmation is received.
*Confidential document for customer/end user only*
3

Crib rails are raised and lowered with a Johns Hopkins Handle.
The side rail or end rails have “trigger” mechanisms that must lock into place to hold up the
rail safely. The red tips of the triggers must be securely seated in the notches of the slide
rods on both ends, and you should barely be able to see the red tip if at all. Grasp the rail
and tug to be certain the rail is in place firmly and properly.
**If the trigger mechanism for the side rails fail to lock into place
properly, remove the crib from service until the mechanism can be
replaced.**
SIDE RAIL OPERATION & SAFETY
To prolong the life of the trigger assembly in the side rail, continue to squeeze the
trigger mechansim as you lower the rail to the desired height and not release until that time.
Letting the red tips of the trigger mechanism drag up and down the slide rods by releasing
the trigger mechanism too early will cause the trigger assembly to wear prematurely and
break.
4

STAFF CONTROL INSTRUCTIONS
Plug in the power cord to the wall outlet .
To raise or lower the head section to desired position press
the touch pad button “HEAD”, “UP” or “DOWN”.
To raise or lower the crib spring to desired position press
the touch pad button “CRIB”, “UP” or “DOWN”.
To raise or lower the foot section to desired position press
the touch pad button “FOOT”, “UP” or “DOWN”.
To use Trendelenberg or Reverse Trendelenberg, spring
should be flat. Then press the touch pad for desired position.
CAUTION! DO NOT USE HEAD OR FOOT CONTROLS IN TRENDELENBERG MODE.
PLEASE NOTE THE MATTRESS PLATFORM SHOULD BE IN THE
LOWEST POSITION TO PERFORM CPR.
5

WEIGHSAFE SCALE OPERATING INSTRUCTIONS
1. Weight Display
2. KG indicator
3. Motion Indicator
4. DISPLAY button
5. ZERO button
6. ON/OFF button
Turning on the WeighSafe Scale:
Turn the scale on by pressing the “ON/OFF” button
once.
The “HARD Manufacturing” logo will appear on the
display screen followed by the current weight.
The WeighSafe Scale may be used with the crib in
any position. The head elevation, foot elevation
and Hi-Lo adjustment will not affect the accuracy of
the WeighSafe Scale.
The scale is designed to be left on at all times and
will always display the current weight. There is no
need to turn the scale off.
To weigh a patient:
Follow your hospital protocol to weigh a patient.
You must ZERO out for an accurate weight
reading.
Remove the child from the crib.
Press the “ZERO” button.
Place the child back in the crib.
The current weight of the patient will immediately
be displayed in kilograms. The WeighSafe Scale
operates only in kilograms.
If the word “Motion” appears on the display, wait a
few seconds for the crib to stabilize. The crib must
be stable to weigh accurately.
Display Light:
WEIGHSAFE SCALE QUESTIONS OR PROBLEMS
Please contact:
HARD Manufacturing Co., Inc.
Parts Department
*Any attempt to disassemble or repair the scale will void the warranty.*
The display backlight will go off after 60 seconds.
Press the “DISPLAY” button to illuminate the
backlight again.
6

1. Press and hold the “Zero” button and “ON” button
at the same time until display turns on.
(1)
2. Select the enter option on the display screen by
pressing the “Display” button. If done correctly,
“Empty Scale” should appear on the display screen.
3. Select the enter option on the display screen
once again by pressing the “Display” button. If done
correctly, “Add 10.0 kg.” should appear on display
screen.
4. Place the 10 kg. weight onto the surface of
thecrib.
5.With the 10 kg. weight still on the crib, select the enter option
on the display screen by pressing the “Display” button. If done
correctly,“Cal done” should appear on display screen.
6. Select the save option on the display screen by pressing the
“Display” button. Calibration is now complete. Press “Zero”
button to exit the calibration setup.
SCALE CALIBRATION INSTRUCTIONS
Your HARD Manufacturing crib will arrive with the scale calibrated and ready for use. You typically should
not need to perform a calibration, however in the event there is a need to do so, use only a certified 10kg
weight to do so and follow the instructions below.
7

MATTRESS PLATFORM DIAGRAM
2
3
4
7
8
9
Head End
1
Foot End
5
6
10 10
11
10
12
13
14
15
17
18
8

MATTRESS PLATFORM PARTS LIST
# Part Description Part # Notes
1Mattress Platform Assembly- 741 91692 Complete mattress platform with all electrical
Mattress Platform Assembly- 752 91690
2Head Pan Assembly- 741 12410
Head Pan Assembly- 752 84159
3Center Pan Assembly- 741 12548
Center Pan Assembly- 752 12547
4Foot Pan Assembly- 741 12410
Foot Pan Assembly- 752 84159
5 Seat Support Bracket- 741 or 752 12544
6 Tilt Indicator 63237 Level for determining angle of elevation
7 Corner Cover 11558
8 Hex Nut 10-32 63402 For Corner Covers
9 Screw 10-32x3/4” 62048
10 Load cell for scales N/A Please contact us regarding scale components
11 Summing Box N/A
12 Control Box 63162
13 Head Motor Assembly 90062
Motor with painted pull tube.14 Foot Motor Assembly 90063
15 Hi-Lo Motor Assembly 90064
16 Transformer 63901
9

SIDE RAIL ASSEMBLY & PARTS LIST
1
2
5
6
7
8
9
10
11
12
13
3
4
16
14
15
# Part Description Part # Notes
1 Side Trim Assembly- 741 & 752 83647 Complete Side Rail
2 Side Trigger Assembly- 741& 752 89117
Teething Bars- 30” wide crib *942 TB Set of 4- not shown.
Protective covering for the tops of the rails
Teething Bars- 36” wide crib *752 TB
3 Glide Slide Bushing 11571 Nylon bushing with cutout
4 Bushing 11518 Solid nylon bushing
5 Johns Hopkins Handle Assembly 72115 Complete Handle Assembly
6 Screw 10-32x1 RH PH MS 63375
Components at the bottom of the
Johns Hopkins Handle
7Retainer Block 11525
8 Split Lockwasher 63454
9 Acorn Nut C/P 10-32 63411
10 Screw 60148 Top of Shield Plate
11 Split Washer 63457
12 Shield Plate Assembly 81216 Plate behind JH Handle
13 “HARD” Sticker 62177 Position: behind JH Handle Assembly
14 “To Raise Sides….” Sticker 63650 Position: left side of each rail
15 “To Lower Sides….” Sticker 63651 Position: On the Shield Plate behind JH Handle
16 “When Child is Left….” Sticker 62184 Position: above JH Handle in the middle of the rail
10
Questo manuale è adatto per i seguenti modelli
3
Indice
Manuali Sistema di sollevamento popolari di altre marche

Genie
Genie Z-60/34 Manuale utente

Screen Technics
Screen Technics INTERFIT Vertical Up Lift Manuale utente

Mortuary Lift
Mortuary Lift ULTIMATE 1000 Manuale utente

Custom Equipment
Custom Equipment Hy-Brid 3 Series Manuale di programmazione

Custom Equipment
Custom Equipment Hy-Brid Lifts 2 Series Manuale di programmazione

Hy-Brid Lifts
Hy-Brid Lifts HB-P3.6 Manuale di programmazione