HBM C2 Series Manuale utente

Mounting Instructions | Montageanleitung |
Notice de montage | Istruzioni per il montaggio
English Deutsch Français Italiano
C2

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64239 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
Mat.: 7-2002.0144
DVS: A0674-5.0 HBM: public
08.2015
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.
Änderungen vorbehalten.
Alle Angaben beschreiben unsere Produkte in allgemeiner
Form. Sie stellen keine Beschaffenheits- oder Haltbarkeits
garantie dar.
Sous réserve de modifications.
Les caractéristiques indiquées ne décrivent nos produits
que sous une forme générale. Elles n'impliquent aucune
garantie de qualité ou de durablilité.
Con riserva di modifica.
Tutti i dati descrivono i nostri prodotti in forma generica e non
implicano alcuna garanzia di qualità o di durata dei prodotti
stessi.

Mounting Instructions | Montageanleitung |
Notice de montage | Istruzioni per il montaggio
English Deutsch Français Italiano
C2

2A0674-5.0 HBM: public C2
English
1 Safety Instructions 4........................................
2 Markings used 9............................................
2.1 The markings used in this document 9..........................
2.2 Symbols on the device 9......................................
3 Scope of supply and equipment variants 10...................
3.1 Scope of supply 10............................................
3.2 Equipment variants 10.........................................
3.3 Accessories 11...............................................
4 General application instructions 12...........................
5 Structure and mode of operation 13...........................
5.1 Transducer 13................................................
5.2 Strain gage covering agent 13..................................
6 Conditions on site 15........................................
6.1 Ambient temperature 15.......................................
6.2 Moisture and corrosion protection 15............................
6.3 Deposits 16..................................................
6.4 Effect of ambient pressure 16..................................
7 Mechanical installation 17....................................
7.1 Important precautions during installation 17......................
7.2 General installation guidelines 18...............................
7.3 Mounting 19..................................................
8 Electrical connection 21......................................
8.1 Connection to an amplifier 21...................................
8.2 Extension cables and cable shortening 22........................
8.3 EMC protection 23............................................

Safety Instructions
4A0674-5.0 HBM: public C2
1 Safety Instructions
Intended use
Force transducers in the C2 type series are designed
solely for measuring static and dynamic compressive
forces within the load limits stated in the specifications.
Any other use is not appropriate.
To ensure safe operation, it is essential to comply with
the regulations in the mounting instructions, the safety
requirements listed below, and the data specified in the
technical data sheets. It is also essential to observe the
applicable legal and safety regulations for the relevant
application.
Force transducers are not intended for use as safety
components. Please also refer to the "Additional safety
precautions" section on the following page. Proper and
safe operation of force transducers requires proper trans
portation, correct storage, setup and mounting, and care
ful operation.
Load‐carrying capacity limits
The information in the technical data sheets must be
complied with when using force transducers. The respec
tive specified maximum loads in particular must never be
exceeded. The following limits set out in the technical
data sheets must not be exceeded:
SForce limits
SLateral force limits
SBending moment and torque
SBreaking forces
SPermissible dynamic loads

Safety Instructions
C2 A0674-5.0 HBM: public 5
STemperature limits
SElectrical load limits
Please note that when several force transducers are
interconnected, the load/force distribution is not always
uniform.
Use as a machine element
Force transducers can be used as machine elements.
When used in this manner, note that to favor greater sen
sitivity, force transducers were not designed with the
safety factors usual in mechanical engineering. Please
refer here to the "Load-carrying capacity limits" section
and Chapter 12, starting on page 29.
Accident prevention
The prevailing accident prevention regulations must be
taken into account, even though the nominal (rated) force
values in the destructive range are well in excess of the
full scale value.
Additional safety precautions
Force transducers cannot (as passive transducers)
implement any safety-relevant cutoffs. This requires addi
tional components and constructive measures, for which
the installer and operator of the plant is responsible.
In cases where a breakage or malfunction of the force
transducer would cause injury to persons or damage to
equipment, the user must take appropriate additional
safety precautions that meet at least the applicable
safety and accident prevention regulations (e.g. auto
matic emergency shutdown, overload protection, catch
straps or chains, or other fall protection).

Safety Instructions
6A0674-5.0 HBM: public C2
The electronics conditioning the measurement signal
should be designed so that measurement signal failure
does not subsequently cause damage.
General dangers of failing to follow the safety
instructions
Force transducers are state-of-the-art and reliable. There
may be dangers involved if the transducers are mounted,
set up, installed and operated inappropriately, or by
untrained personnel. Every person involved with setting
up, starting-up, operating or repairing a force transducer
must have read and understood the mounting instruc
tions and in particular the technical safety instructions.
The force transducers can be damaged or destroyed by
non-designated use of the force transducer or by non-
compliance with the mounting and operating instructions,
these safety instructions or other applicable safety regu
lations (BG safety and accident prevention regulations)
when using the force transducers. A force transducer can
break, particularly in the case of overloading. The break
age of a force transducer can cause damage to property
or injury to persons in the vicinity of the force transducer.
If force transducers are not used as intended, or if the
safety instructions or specifications in the mounting and
operating instructions are ignored, it is also possible that
a force transducer may fail or malfunction, with the result
that persons may be injured or property damaged (due to
the loads acting on or being monitored by the force trans
ducer).
The scope of supply and performance of the transducer
covers only a small area of force measurement technol
ogy, as measurements with strain gage sensors presup
pose the use of electronic signal processing. Equipment
planners, installers and operators should always plan,
implement and respond to the safety engineering consid

Safety Instructions
C2 A0674-5.0 HBM: public 7
erations of force measurement technology in such a way
as to minimize residual dangers. Pertinent national and
local regulations must be complied with.
Conversions and modifications
The design or safety engineering of the transducer must
not be modified without our express permission. Any
modification shall exclude all liability on our part for any
damage resulting therefrom.
Maintenance
The force transducers of the C2 series are maintenance
free.
Disposal
In accordance with national and local environmental pro
tection and material recovery and recycling regulations,
old transducers that can no longer be used must be dis
posed of separately and not with normal household
garbage.
If you need more information about disposal, please con
tact your local authorities or the dealer from whom you
purchased the product.
Qualified personnel
Qualified personnel means persons entrusted with siting,
mounting, starting up and operating the product who pos
sess the appropriate qualifications for their function.
This includes people who meet at least one of these
three requirements:
SKnowledge of the safety concepts of automation tech
nology is a requirement and as project personnel, you
must be familiar with these concepts.

Safety Instructions
8A0674-5.0 HBM: public C2
SAs automation plant operating personnel, you have
been instructed how to handle the machinery. You are
familiar with the operation of the equipment and tech
nologies described in this documentation.
SAs commissioning engineers or service engineers,
you have successfully completed the training to repair
the automation systems. You are also authorized to
activate, ground and label circuits and equipment in
accordance with safety engineering standards.
It is also essential to comply with the legal and safety
requirements for the application concerned during use.
The same also applies to the use of accessories.
The force transducer may only be installed by qualified
personnel, strictly in accordance with the specifications
and with the safety requirements and regulations.
Altri manuali per C2 Series
2
Indice
Lingue:
Altri manuali HBM Trasduttore