HID Mercury LP1502 Manuale utente

HIDMercury™ LP1502 Controller
Installation and Specifications
PLT-05244, A.3
June 2021
HIDMercury™ LP1502 Controller Installation and Specifications
Powering
Trusted Identities

Copyright
© 2020 - 2021 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
This document may not be reproduced, disseminated or republished in any form without the prior written
permission of HID Global Corporation.
Trademarks
HID GLOBAL, HID, the HID Brick logo, the Chain Design, and HIDMercury are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other countries and may not be
used without permission. All other trademarks, service marks, and product or service names are trademarks
or registered trademarks of their respective owners.
Contacts
HID Global Technical Support: www.hidglobal.com/support.
Americas and Corporate Asia Pacific
611 Center Ridge Drive
Austin, TX 78753
USA
Phone: +1866 607 7339
19/F 625 King’s Road
North Point, Island East
Hong Kong
Phone: +852 3160 9833
Europe, Middle East, and Africa (EMEA) Brazil
3 Cae Gwyrdd
Green Meadow Springs
Cardiff CF15 7AB
United Kingdom
Phone: +44 (0) 1440 711 822
Condomínio Business Center
Av. Ermano Marchetti, 1435
Galpão A2 - CEP 05038-001
Lapa - São Paulo / SP Brazil
Phone: +55 11 5514-7100
For additional offices around the world, see www.hidglobal.com/contact/corporate-offices.
What's new
Date Description Revision
June 2021 Minor updates. A.3
A complete list of revisions is available in Revision history.
PLT-05244, A.3 2 June 2021
Powering
Trusted Identities HIDMercury™ LP1502 Controller
Installation and Specifications

Section 01
Powering
Trusted Identities
Overview

1.1 LP1502 intelligent controller with two reader interfaces
The LP1502 intelligent controller provides decision making, event reporting, and database storage for the
HIDMercury hardware platform. Two reader interfaces provide control for two physical barriers.
Host communication is via the on-board 10-BaseT/100Base-TX Ethernet port, or the Micro USB port (2.0)
with an optional Micro USB to Ethernet adapter.
Each reader port can accommodate a reader that uses TTL (D1/D0, Clock/Data), F/2F (standard or
supervised), or 2-wire RS-485 device signaling (OSDP reader for example), and also provides tri-state LED
control and buzzer control (one wire LED mode only).
Four Form-C relay outputs can be used for door strike control or alarm signaling.
Eight inputs are provided that can be used for monitoring the door contacts, exit push buttons, and alarm
contacts. Input circuits can be configured as unsupervised or supervised.
The LP1502 requires 12 to 24 V DC for power.
1.2 LP1502 hardware
PLT-05244, A.3 4 June 2021
Powering
Trusted Identities HIDMercury™ LP1502 Controller
Installation and Specifications

Section 02
Powering
Trusted Identities
LP1502 wiring and setup

2.1 LP1502 connections
TB1-1 GND Power fault input
TB1-2 FLT
TB1-3 GND Cabinet
TB1-4 TMP Tamper input
TB1-5 GND Power input
TB1-6 VIN: 12 to 24 V
DC
TB2 N/A Not used
TB3-1 GND SIO port (2-wire RS-485)
TB3-2 TR- (B)1
TB3-3 TR+ (A)1
TB4-1 IN2 Input 2
TB4-2 IN2
TB4-3 IN1 Input 1
TB4-4 IN1
TB5-1 IN4 Input 4
TB5-2 IN4
TB5-3 IN3 Input 3
TB5-4 IN3
TB6-1 IN6 Input 6
TB6-2 IN6
TB6-3 IN5 Input 5
TB6-4 IN5
TB7-1 IN8 Input 8
TB7-2 IN8
TB7-3 IN7 Input 7
TB7-4 IN7
PLT-05244, A.3 6 June 2021
Powering
Trusted Identities HIDMercury™ LP1502 Controller
Installation and Specifications

TB8-1 GND Reader 1 - Ground
TB8-2 DAT/D0 Reader 1 - Data/Data 0/TR- (A)1
TB8-3 CLK/D1 Reader 1 - Clock/Data 1/TR+ (B)1
TB8-4 BZR Reader 1 - Buzzer
TB8-5 LED Reader 1 - LED
TB8-6 VO Reader power
TB9-1 GND Reader 2 - Ground
TB9-2 DAT/D0 Reader 2 - Data/Data 0/TR- (A)1
TB9-3 CLK/D1 Reader 2 - Clock/Data 1/TR+ (B)1
TB9-4 BZR Reader 2 - Buzzer
TB9-5 LED Reader 2 - LED
TB9-6 VO Reader power
TB10-1 NO Out 1 - Normally open contact
TB10-2 C Out 1 - Common contact
TB10-3 NC Out 1 - Normally closed contact
TB10-4 NO Out 2 - Normally open contact
TB10-5 C Out 2 - Common contact
TB10-6 NC Out 2 - Normally closed contact
TB11-1 NO Out 3 - Normally open contact
TB11-2 C Out 3 - Common contact
TB11-3 NC Out 3 - Normally closed contact
TB11-4 NO Out 4 - Normally open contact
TB11-5 C Out 4 - Common contact
TB11-6 NC Out 4 - Normally closed contact
1. Terms (A) and (B) are from the RS-485 standard.
PLT-05244, A.3 7 June 2021
Powering
Trusted Identities HIDMercury™ LP1502 Controller
Installation and Specifications

2.1.1 Jumpers and jacks
The LP1502 processor hardware interface is configured using jumpers to setup the reader port power and
end of line termination.
Jumpers Set at Description
J1 N/A Factory use only
J2 N/A 10-Base-T/100Base-Tx Ethernet connection (Port 0)
J3 N/A Factory use only
J4 N/A N/A
J5 OFF RS-485 EOL Terminator is OFF
ON RS-485 EOL Terminator is ON
J6 N/A Micro USB port (2.0)
J7 Reader power select. See caution below.
12V 12 V DC at reader ports
PASS VIN "Pass Through" to reader ports
J8 N/A microSD card
J10-1 N/A Remote Status LED #1.1
J10-2 N/A Remote Status LED #2.1
J10-3 N/A Remote Status LED #3.1
J10-4 N/A Remote Status LED #4.1
J19 OFF Backup battery is OFF.
ON Backup battery is ON. See Memory and real time clock backup battery
1. Observe polarity connection to LED. External current limiting is not required.
Caution: Install jumper J7 in the 12 V position ONLY if the input voltage (VIN) is greater than 20V DC. Failure
to do so may damage the reader or LP1502.
PLT-05244, A.3 8 June 2021
Powering
Trusted Identities HIDMercury™ LP1502 Controller
Installation and Specifications

2.2 DIP switches
The four switches on S1 DIP switch configure the operating mode of the LP1502 processor. DIP switches are
read on power-up except where noted. Pressing reset switch S2 causes the LP1502 to reboot.
1 2 3 4 Definitions
OFF OFF OFF OFF Normal operating mode.
ON X OFF OFF After initialization, enable default User Name (admin) and Password (password). The
switch is read on the fly, a re-boot is not required. See IT security for additional
information.
OFF ON OFF OFF Use factory default communication parameters.
ON ON OFF OFF Use OEM default communication parameters. Contact system manufacture for details.
See Bulk erase configuration memory.
ON ON OFF OFF Bulk Erase prompt mode at power up. See Bulk erase configuration memory.
X X X ON Makes the LP1502 report and function like an EP1502. To be used in situations where the
host software has not been updated to support the LP series product line.
Note: All other switch settings for unassigned and are reserved for future use. X = don’t care.
Caution: In the factory or OEM default modes, downloaded configuration/database is not saved to flash
memory.
2.3 Factory default communication parameters
Interface 1 (NIC1)
Network: static IP address 192.168.0.251
Subnet mask 255.255.0.0
Default gateway 192.168.0.1
DNS server 192.168.0.1
Primary host port IP server, Data security: TLS if Available, port 3001, communication address: 0
Alternate host port Disabled
PLT-05244, A.3 9 June 2021
Powering
Trusted Identities HIDMercury™ LP1502 Controller
Installation and Specifications

2.4 Bulk erase configuration memory
The bulk erase function can be used for the following:
nErase all configuration and cardholder database (sanitize board, less third party applications).
nUpdate OEM default parameters after OEM code has been changed.
nRecover from database corruption causing the LP1502 board to continuously reboot.
Note: If clearing the memory does not correct the initialization problem, contact Tech Support
2.4.1 Bulk erase steps
1. Set S1 DIP switches 1 and 2 to ON, and 3 and 4 to OFF.
2. Apply power to the LP1502 board. LED 1 is on for about 15 seconds while LP1502 boots up.
3. Change DIP switches 1 or 2 to OFF Within 10 seconds after LEDs 1 and 2, and LEDs 3 and 4 start flashing
alternately at a rate of 0.5 seconds. If these switches are not changed, the LP1502 board will power up
using the OEM default communication parameters.
4. LED 2 will flash indicating that the configuration memory is being erased. Full memory erase takes up to
60 seconds.
5. When complete, only LEDs 1 and 4 will flash for about three seconds.
6. The LP1502 board will complete its initialization within two seconds after LEDs 1 and 4 stop flashing.
Caution: Do not remove power during the bulk erase process.
PLT-05244, A.3 10 June 2021
Powering
Trusted Identities HIDMercury™ LP1502 Controller
Installation and Specifications
Indice
Altri manuali HID Controllori

HID
HID VertX EVO V2000 Manuale utente

HID
HID EDGE EVO EH400-K Manuale utente

HID
HID EDGE EVO EH400 Manuale utente

HID
HID ACW2-XN Manuale utente

HID
HID VertX EVO Series Manuale utente

HID
HID VertX EVO V1000 Manuale utente

HID
HID iCLASS SE RB25F Manuale utente

HID
HID Signo 25B Manuale utente

HID
HID Mercury LP1501 Manuale utente

HID
HID Vertx CS V100 Manuale utente