Hillphoenix 05DMA Manuale utente

DAIRY/DELI
/PRODUCE
CASES
MODEL: O5DMA
HANDBOOK
INSTALLATION & OPERATION
P056442G
Rev. 10 12/04

CAUTION
Do not walk or put heavy
objects on top of case.
WARNING
disconnect power to the fans
before cleaning case.
HIGH
PRESSURE
HIGH
PRESSURE
WARNING
Some surfaces may be hot when
case is in operation.
HIGH
PRESSURE
WARNING
Always turn off power to lights
before servicing.
HIGH
PRESSURE
DANGER
Electrical Shock Hazard
Always disconnect power to case
when servicing or cleaning.
HIGH
PRESSURE

Welcome to the ORIGIN2display case family. We’re very pleased you
joined us.
This installation and operation handbook has been especially
prepared for everyone involved with ORIGIN2display cases – owners,
managers, installers and maintenance personnel.
You’ll find this book different than traditional manuals. The most
dramatic difference is the use of many more illustrated instructions to
make it easier to read and to help you get the most from this innovative
new design. When you follow the instructions you should expect
remarkable performance, attractive fits and finish, and long case life.
We are interested in your suggestions for improvement both in case
design and in this handbook. Please call/write to:
Hill PHOENIX
Marketing Services Department
1925 Ruffin Mill Rd.
Colonial Heights, VA 23834
Tel: 804-526-4455
Fax: 804-526-7450
or visit our web site at
www.hillphoenix.com
We wish you the very best in outstanding food merchandising and a
long trouble-free operation.


1
TABLE OF CONTENTS
GENERAL INFORMATION – PAGES 2-3
General information, first step recommendations and case dimensional drawings.
THE USE OF CASTERS – PAGE 4
Cases roll on casters–general use and caster removal.
INSTALLATION - PAGE 5
Instructions on how to trim out cases with illustrations.
REFRIGERATION PIPING - PAGE 6
Diagram showing the refrigeration components of the self contained cases.
COMPONENT DEFINITIONS - PAGE 7
Operational descriptions of the refrigeration components.
PLUMBING – PAGE 8
Information on drain connections.
ELECTRICAL HOOKUP, CONTROL SETTINGS, AND WIRING DIAGRAMS – PAGES 9-16
Complete information on electrical connections.
CASE OPERATION – PAGE 17
Recommended settings for all case controls.
DEFROST AND TEMPERATURE CONTROL – PAGE 18
Defrost data. Sensor bulb locations.
AIR FLOW AND PRODUCT LOADING – PAGE 19
Air flow and load limits.
USE AND MAINTENANCE – PAGES 20-21
Cleaning and fan information.
PARTS ORDERING – PAGES 22-24
Replacement parts identification.
NOTES - PAGES 25-26
PRODUCT WARRANTY - Inside Back Cover

2
GENERAL INFORMATION
DESCRIPTION OF CASES: The refrigerated display cases described in this handbook
are part of the Hill PHOENIX, Origin2design series. Specifically covered in this manual is
model O5DMA multi-deck dairy/deli/produce self-contained.
STORE CONDITIONS: Hill PHOENIX cases are designed to operate in an air conditioned
store with a system that can maintain 75OF (24OC) store temperature and 55 percent (maxi-
mum) relative humidity (CRMA conditions). Case operation will be adversely affected by
exposure to excessively high ambient temperatures and/or humidity.
REFRIGERATION SYSTEM OPERATION: Air cooled condensing units require ventilation for
efficient performance of condensers. Machine room temperatures must be a minimum of
65OF in winter and a maximum of 95OF in summer. Minimum condensing temperatures
should be no less than 70OF.
RECEIVING CASES: Examine fixtures carefully for shipping damage and shortages. For
information on shortages contact the Service Parts Department at 1-800-283-1109.
APPARENT DAMAGE: A claim for obvious damage must be noted on the freight bill or
express receipt and signed by the carriers agent, otherwise the carrier may refuse the claim.
CONCEALED DAMAGE: If damage is not apparent until after the equipment is unpacked,
retain all packing materials and submit a written request to the carrier for inspection within
15 days of receipt of equipment.
LOST ITEMS: This equipment has been carefully inspected to insure the highest level of
quality. Any claim for lost items must be made to Hill PHOENIX within 48 hours of receipt
of equipment.
TECHNICAL SUPPORT: If any technical questions arise regarding a refrigerated display
case contact our Customer Service Department in Richmond at 1-804-526-4455. For any
questions regarding our refrigeration systems or electrical distribution centers contact our
Customer Service Department in Conyers at 1-770-285-3200.
CONTACTING FACTORY: Should you need to contact Hill PHOENIX regarding a specific
fixture, be sure to know the case model number and serial number. This information is on
the serial plate located on the top flue panel of the case (see next page for details). Ask for
a Service Parts Representative at 1-804-526-4455.

NOTES:
zFRONT SILL HEIGHT AND OVERALL CASE HEIGHT VARYSWITH BASEFRAME HEIGHT
zA 2" MINIMUM AIR GAP IS REQUIRED BETWEENTHE REAR OFTHE CASE AND A WALL
zAVAILABLE SHELF SIZES: 10", 12", 14", 16", 18", 20", 22" & 24"
FRONT OF CASE
48 in [121.9 cm] {4' case}
72 in [182.9 cm] {6' case}
96 in [243.8 cm] {8' case}
43 1/4 in
[109.9 cm]
35 1/16 in
[89.0 cm]
31 9/16 in
[80.2 cm]
9 7/8 in
[25.1 cm]
CONDENSING UNIT
6 3/16 in [15.7 cm]
3 in [7.6 cm] JUNCTION BOX 3 in [7.6 cm]
12 in
[30.5 cm]
39 1/4 in
[99.7 cm]
DRAIN PAN
DRAIN ASSEMBLY
1 1/2 in [3.8 cm]
{END}
3 in [7.6 cm]
C
L
39 11/16 in [100.7 cm]
5 1/8 in
[13.1 cm]
COIL PLENUM
6 13/16 in [17.2 cm]*
43 1/4 in [109.9 cm]
32 in [81.3 cm]
59 in
[149.9 cm]
3rd ROW LIGHT
(OPTIONAL)
9.75" MIRROR
(OPTIONAL)
13" MIRROR
(OPTIONAL)
14 1/2 in
[36.9 cm]
18 11/16 in
[47.5 cm]
55 13/16 in
[141.7 cm]
THROAT
STANDARD
DAIRY FRONT
31 9/16 in [80.2 cm]
39 1/4 in [99.7 cm]
17 in
[43.2 cm]
21 3/16 in
[53.9 cm]
53 5/16 in [135.4 cm] THROAT 50 13/16 in [129.0 cm] THROAT
19 1/2 in
[49.6 cm]
23 11/16 in
[60.2 cm]
48 5/16 in [122.7 cm]THROAT
22 in
[55.9 cm]
26 3/16 in
[66.6 cm]
50 13/16 in [129.0 cm]THROAT
19 1/2 in
[49.6 cm]
23 11/16 in
[60.2 cm]
2 1/2" EXTENDED FRONT
W/ NOSE LIGHT 5" EXTENDED FRONT
5" EXTENDED FRONT
W/ NOSE LIGHT 7 1/2" EXTENDED FRONT
W/ NOSE LIGHT
102 7/8 in
[261.3 cm]
100 13/16 in
[256.1 cm]
19 3/16 in
[48.7 cm]
3
MODEL
O5DMA
Amp Plate &
Serial Plate
Location

4
CASES
MOVE ON
CASTERS
FOR EASIER INSTALLATION
ORIGIN2cases are manufactured and shipped to
stores with casters installed on the base frame to
make the job of moving cases easier for everyone
involved with the manufacturing, shipping and instal-
lation process.
Casters not only speed up the process, but they also
reduce the chance of damage from raising and low-
ering cases with ”J” bar to place them on dollies,
skates or rollers. In most situations, one or two per-
sons can move the case with ease.
34
12
CASTERS MAY BE DISCARDED.
ROLL OUT OF TRUCK. When there is a truck - level
delivery dock, cases may be rolled directly from the
truck to the store floor. [CAUTION] If skid boards are
required to unload cases, casters should be removed
prior to sliding them down the skid; after which they
can be reinstalled on case.
ROLL TO LINEUP POSITION. Casters may remain in
place to move the cases to staging areas around the
store, prior to final installation. When ready for final
line-up, roll the case to set position, then remove
casters.
REMOVE COTTER PIN. Removing the casters is
easy. Simply flatten and hammer out cotter pins
then lift the case with “J” bar, and the casters will
fall off.
[CAUTION] Make certain hands are out of the way.

5
The O5DMA is shipped with most of
the exterior panels and trim already installed.
The only exterior parts that need to be
installed when the case arrives are the kick-
plate and the end kickplates. If the cases are
equipped with contour front panels the upper
kickplate retainer is also shipped loose with
the case.
The kickplate, which is shipped in the
case, simply slips up and behind the front
panel and then down onto the “J” rail. See
illustration 1below for details. When
installing the upper kickplate retainer make
sure it is placed behind the front panel lip as
shown in illustration 1below.
The end kickplates, which are also
shipped in the case, are attached to the
baseframes directly under the ends with the
screws provided. There are two, smoke grey
plug buttons that are inserted into each end
kickplate to cover the screw holes, see illus-
tration 2below.
1
2
KICKPLATE
FRONT PANEL
“J” RAIL
SCREW
PLUG BUTTON
END KICKPLATE
BASEFRAME
END
KICKPLATE
FRONT PANEL LIP
“J” RAIL
UPPER KICKPLATE
RETAINER
FLAT FRONT PANELS CONTOUR FRONT PANELS
INSTALLATION

6
REFRIGERATION PIPING
The diagram below illustrates all of the
refrigeration components in the O5DMA.
The components surrounded by the box are
located in the case tank. Basic definitions of
these components are listed on the following
page.
If it becomes necessary to penetrate
the case bottom for any reason, make certain
it is sealed afterward with canned-foam
sealant and caulk.
The expansion valve and other controls
are located on the left-hand side of the case
and are accessible without lifting the fan
plenum. The controls cluster may be reached
by lifting only the left hand deck pan minimiz-
ing the need to unload product. The compres-
sor and condensing unit are located on top of
the case for easy access.
TXV
Bulb
Evaporator
Fans
Condenser
Fans
Service
Valve
TXV
1/4”
Access
Valve
Evaporator
Condenser
Compressor
Receiver
Service
Valve
Filter
Drier
Tank
Area
Flow Direction
Suction Line
Solenoid
Dual Pressure
Control
Flow Direction
Sight
Glass
Accumulator
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Hillphoenix Frigorifero



















