10
10
mode. Half a second after you have given the command, BMS4S will sent it to the radio.
When this is done you will see a blink on the LED. After that you have 10 seconds to
reconnect to get the response that the radio gave to your command. Unfortunately, not all
bluetooth devices work exactly the same. If this does not work, check the manual for the
bluetooth device you have and see if there are any other way to change its settings. But you
do not have to change anything, it will work fine anyway.
ce Clear Extremepointlog
will clear all entries from the log.
cm Clear Memorylog
will clear all entries from the log. You can add a text with 12 characters e.g. to state when
the logging was started. Example:
cm=24/12-09:30
p Print
will produce a printout of cell-voltage, total voltage, current and estimated SoC. Example:
U=3.283 3.283 3.283 3.284 13.133 I=0.000 SoC=41
pe Print Extremepointlog
Command pe will give a printout like this:
HVE , 3.599 , 3.600 , 3.598 , 3.599 , 14.396 , 77.130 ,
HVA , 3.517 , 3.520 , 3.518 , 3.520 , 14.074 , 14.970 ,
LVE , 2.997 , 2.996 , 2.996 , 2.997 , 11.986 , -1.663 ,
UBC , 3.563 , 3.564 , 3.563 , 3.555 , 14.264 , 75.622 , 0.720 , 0.720 , 0.810 , 0.010 ,
UBI , 3.563 , 3.564 , 3.563 , 3.565 , 14.254 , 75.622 , 0.720 , 0.720 , 0.810 , 0.010
UBE , 3.277 , 3.277 , 3.277 , 3.277 , 13.109 , -1.204 ,
VBI , 3.480 , 3.500 , 3.499 , 3.497 , 13.976 , 75.622,
This time the log contained six entries, can store around 50 entries. The log is cleared by
command ce. The first four numbers in all lines are the voltage of each cell when the event
happened. The fifth is the total voltage, and the sixth is the current at the event.
HVE means “high voltage event”, HVA “high voltage absorption event” (timeout has
happened in VoltAbsorbtion phase, see command va), LVE “low voltage event”.
UBC means “unbalance calculation” and the four last numbers are the amount of energy
that were charged into each cell at the latest cell balance measurement (done by coulomb
counting), with the sort Ah. This counting starts when the voltage passes VoltBalance . So
right now, there is an unbalance of 0.8 Ah (0.810-0.010) between cell 3 and cell 4, where cell
3 is the best charged one. UBI means “unbalance calculation and balancing initiated”
(balancing will only work if a balancing board has been installed). UBE then means that the
initiated balancing has ended. If an UBE is missing after an UBI then the system has been
switched off before the balancing ended, which is nothing to worry about. If there are
enough remining unbalance the process will restart at the next unbalance-calculation. If
there are multiple UBI in sequence with the same order of unbalance this indicates that you
can increase how much of the unbalance you try to remove each time. Then you can