Hunter ECO 14 Manuale utente

ECO
INSTALLATION
MANUAL

In a world full of impersonators,
be an original. We invented
the ceiling fan, and we stand
behind our products.
AUTHENTICITY
CONTENTS
!BEFORE YOU BEGIN
INSTALLATION
REFERENCE
SAFETY & PRECAUTIONS 2-3
FAN PLACEMENT 4
MAINTENANCE 5
IN THE BOX 6
TOOLS NEEDED 7
STEP 1: MOUNTING 8
STEP 2: RETENTION SYSTEM 9
STEP 3: MOTOR ASSEMBLY 10
STEP 4: CONTROL PANEL 11
STEP 5: STANDARD CONTROL 12
STEP 6: GUY WIRES 13
STEP 7: BLADES 14
ELECTRICAL 15
MOUNTING CONFIGURATION 16
FIRE PANEL 17
TROUBLESHOOTING 18
1886
The Hunter legacy is not
only about quality—it’s about
longevity. We invented the
ceiling fan. We build fans that
last, fans that are designed
as fans. We design our fans
while considering each person
in the process—from the
installer to the owner.
LEGACY

!BEFORE YOU BEGIN SAFETY & PRECAUTIONS
2
READ THE ENTIRE MANUAL BEFORE OPERATING THE FAN
Read and understand this manual before installing or operating a fan unit. Installation, adjustment, repair, or maintenance
must be performed by qualified personnel.
Follow all safety practices and instructions during the installation, operation, and servicing of the fan. Failure to
apply these safety practices could result in death or serious injury. If you do not understand the instructions, please
call our Technical Department at 1-844-593-FANS (3267) for guidance.
This unit is for professional use only and is not required to comply with EN 61000-3-2:2006.
Professional installation practice requires following local utility company guidelines for connecting
to AC mains.
Conforms to UL STD 507 and Certified to CSA STD C22.2 No. 113
All fan controls and incoming power should be installed only by qualified technicians familiar with the requirements of
the National Electrical Code and local codes. Failure to follow these guidelines will void the manufacturer’s warranty. All
electrical controls are configured at the factory and are ready to use. No user adjustments are available. Follow the included
installation instructions when installing this device to ensure proper operation. Do not make any changes to any part of the
fan without first consulting Hunter Industrial Fan. Installation is to be in accordance with the National Electrical Code, ANSI/
NFPA 70-1999 and local codes.
To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades, or
cleaning the fan. Do not insert foreign objects in between rotating fan blades.
The user is responsible for compliance with all international and National Electrical Code requirements with respect to
grounding of all equipment. Many of the parts of this unit operate at line voltage. DO NOT TOUCH any live conductors. Install
all covers before applying power or starting and stopping the unit. To reduce the risk of electric shock or injury, use this
unit only in the manner intended by the manufacturer. If you have questions, call our Technical Department at 1-844-593-
FANS (3267).
Before installing, servicing, or cleaning the unit, switch power off at the service panel and lock the service disconnecting
means to prevent power from being switch on accidentally. When the service disconnect means cannot be locked, securely
fasten a prominent warning sign, such as a tag to the service panel. To reduce a prominent risk of electrick shock or injury,
use this unit only in the manner intended by the manufacturer. if you have any questions, call our Technical Department
at 1-844-593-FANS (3267).
DAMAGED EQUIPMENT
Do not operate or install any fans or fan accessories that appear to be damaged. Failure to follow this instruction can
result in death, serious injury, or equipment damage.
SERVICE
If the fan does not operate properly using the procedures in this manual, remove all power to the unit and contact our
Technical Department for further assistance at 1-844-593-FANS (3267). Keep all body parts clear of moving parts at all
times. All electrical troubleshooting and repair must be done by a qualified technician and meet all applicable codes.
5007479
WARNING! Be aware of electric shock hazard, explosion, or arc ash

!BEFORE YOU BEGIN SAFETY & PRECAUTIONS
3
KEY RETENTION SYSTEM COMPONENTS
Our fans are engineered with safety features that prevent pieces of the fan from falling in the unlikely event of a catastrophic
failure. Install the retention cable on EVERY fan. The retention cable, if installed per Hunter Industrial Fan specifications, will
provide comprehensive protection of people, equipment, and property in the unlikely event of mounting system failure.
MARK THE FLOOR TO ALERT PERSONNEL
When mounting a fan in an area where materials may be elevated into its path, we recommend marking or painting the floor
with a large crosshatched circle to alert personnel of the overhead location of fans.
WEIGHT CONSIDERATIONS
We recommend that a building structure be capable of holding approximately twice the stated hanging weight of the fan.
The hanging weight of a 24’ fan with a standard 4’ downrod is 212 lbs.; the maximum hanging weight of a 24’ fan with a 10’
downrod is 232 lbs.
If there is any uncertainty in the strength of the building structure, a professional structural engineer should perform a
thorough evaluation of the building prior to purchasing the fans. Hunter Industrial Fan provides guidelines for mounting fans;
however, it is the sole responsibility of the building owner and installer to ensure the safety of the mounting system, that the
building structure is sound, and that the installation complies with all federal, state, and local codes.
CHECK FEDERAL, STATE, AND LOCAL CODES
Code compliance is the responsibility of the installer.
Check all relevant codes to make sure that all product certifications, product listings, and building regulations are met.
WINDY CONDITIONS
Fans should not be operated or installed in locations where it is frequently windy.
CAUTION! The fan should never be run without a properly installed retention cable, which is supplied with every fan, along with all required hardware.
If the retention cable is not installed, the warranty will be voided.

4
!BEFORE YOU BEGIN FAN PLACEMENT
2 FT
Min
2 FT
Min
20-25% OF
FAN DIAMETER
MINIMUM CLEARANCE
SPRINKLER SYSTEMS AND FAN PLACEMENT
In any installation where fire sprinklers are in place, the fan should not interfere with their correct operation. Fans should be
located fewer than 3 feet below a sprinkler and placed central to each sprinkler quadrant. Our industrial control panel can be
connected to a fire relay system, which, in an emergency, will stop fans in case of fire.
Prior to installing fans, review all codes applicable to sprinkler systems and fans to ensure code compliance and refer to NFPA
13 Standard from the National Fire Prevention Association.
Please call our Technical Department for guidance at 1-844-593-FANS (3267). However, it is your sole responsibility to see that the
installation is completed to code and that it is correct.
OTHER INFORMATION ON PLACEMENT AND SPACING
If possible, avoid mounting fans directly below lights or skylights to avoid any strobe effect caused by moving airfoils. Note,
a large fan, 20 to 24 feet in diameter, performs best at 20 to 30 feet above the floor, but acceptable performance has been
demonstrated as low as 10 feet and as high as 50 feet.
If the building has a mezzanine, fans should be mounted so a person cannot reach a fan in any way from the upper level/
deck. Make certain that fans are positioned so that the airfoil tips are at least 3 feet away from any area where a person may
be able to extend outward to reach them.
Fans should not be located directly beneath any air discharge. This includes air conditioning units and evaporative coolers.
Such equipment can be used effectively in conjunction with HVLS fans, but the discharge must be located outside of the
swept area of the fan.

!BEFORE YOU BEGIN MAINTENANCE
5
GUY WIRE CHECK
Checking a fan’s guy wires for tension and inspecting for frayed sections could prevent a problem before it occurs. Fan
owners should confirm that the guy wires are not wrapped around any sharp edges. We recommend attaching guy wires
to the building with provided clamps to prevent fraying. Turnbuckles should be checked to ensure tightness. If they are
loose, the guy wire cables need to be re-tensioned.
AIRFOIL CLEANING
Depending on the commercial application of the fan, there can be quite a bit of dust or other particulates that cling
to the fan’s airfoils. We recommend fan owners keep airfoils clean by having a maintenance person or skilled trade
professional–who has experience using a lift–wipe the fan airfoils with a rag or sponge using hot water or regular cleaning
solutions. Please do not use chlorine or any chemicals containing chlorine.
RETENTION SYSTEM CHECK
Each fan is installed with a retention system. The retention cable is attached to the motor and wraps around the building
structure. The safety cable is an important part of the safety system and protects users from a catastrophic event. It is
critical for fan owners to ensure that it is intact and properly secured.
REPLACEMENT PARTS
Please call our Technical Department at 1-844-593-FANS (3267).

6
!BEFORE YOU BEGIN IN THE BOX
a) (1) 100ft Cat5 Cable
(Terminated)
b) (2) RJ45 Connectors
COMMUNICATON KIT
a) b)
a) (1) Gripple Kit
b) (4) Beam Clamps
c) (4) Turnbuckles
GUY WIRE KIT
a)
c)
b)
a) (2) Shims
b) (2) Clamps
c) (4) Bolts, Nuts &
Washers
MOUNTING HARDWARE KIT
c)
b)
a)
e)
FAN COMPONENTS
c) d)
a) b) a) (1) Downrod
b) (1) Motor & (4) Motor Nuts
c) (1) Standard Control
d) (1) Control Panel
e) (4) Blades

!BEFORE YOU BEGIN TOOLS NEEDED
Metric Ratcheting Wrench Set
Metric (Deep & Short) Socket and Ratchet Set
Standard (Deep & Short) Socket and Ratchet Set
Metric Allen Wrench Set
Metric Allen Socket Set
Tape Measure
Magnetic Level
Torque Wrench
Wire Rope Cutters
Phillips and Flat Head Screwdrivers
#10 to #14 AWG Strippers
Multimeter
Cat5 Termination Tools (optional)
7

8
INSTALLATION MOUNTING
1
A
BOLTS
WASHERS
CLAMPS
SHIMS
NUTS
B
D
C
A
Secure bracket and
downrod to lift and raise
to I-beam.
B
Assemble the mount with
shims and clamps on
bracket. Hook the clamp
on one side of the I-beam
and tighten hardware
until the mount is snug
but can still be moved.
C
Assemble the opposing
shim and clamp on to the
I-beam and hand tighten.
D
Center the mount under
the I-beam. Ensure the
clamps have maximum
engagement on both
sides and tighten
hardware.
WARNING: Support Directly From Building Structure

INSTALLATION RETENTION SYSTEM
2
AB
Secure rst clamp on the loose
end of the cable.
Secure the remaining clamp in
the center of the two installed
clamps.
Secure the second clamp to the
cable approximately 6 inches
from the rst clamp.
B
Secure remaining cable
to itself with cable
clamps. Coil excess cable
and secure.
A
Wrap retention cable
around beam or building
structure.
9
Altri manuali per ECO 14
1
Indice
Altri manuali Hunter Fan

Hunter
Hunter 21327 Manuale utente

Hunter
Hunter DDI Manuale utente

Hunter
Hunter Stylus Manuale utente

Hunter
Hunter 42620-01 Manuale di istruzioni

Hunter
Hunter 42411-01 Manuale utente

Hunter
Hunter Pelston Manuale utente

Hunter
Hunter 21425 Manuale di istruzioni

Hunter
Hunter 82022 Manuale utente

Hunter
Hunter 50310 Manuale utente

Hunter
Hunter 53240 Manuale di istruzioni

Hunter
Hunter Minimus Manuale utente

Hunter
Hunter 42653-01 Manuale di istruzioni

Hunter
Hunter 23714 Manuale

Hunter
Hunter 21591 Manuale

Hunter
Hunter Malden Manuale utente

Hunter
Hunter 28528 Manuale utente

Hunter
Hunter Echo Bluff Manuale utente

Hunter
Hunter 26487 Manuale

Hunter
Hunter 21187 Manuale utente

Hunter
Hunter 21894 Manuale