Instruction Manual
Objective Heater Universal – Silver Line
Version 1.0
for use with ibidi Heating System Slide / Dish – Silver Line
and ibidi Heating System 4 Slides – Silver Line
12110, 12720,
12722, 12111
12130, 12131
.com

Objective Heater Universal – Silver Line
Contact
ibidi GmbH
Lochhamer Schlag 11
82166 Gr¨
afelfing
Germany
Phone: +49 89 / 520 46 17 - 0
Fax: +49 89 / 520 46 17 - 59
E-mail: [email protected]
Internet: ibidi.com
Instruction Manual 3 Version 1.0 (June 1, 2022)

Objective Heater Universal – Silver Line
Contents
1 Preamble 5
1.1 Introduction ........................................... 5
1.2 Introduction ........................................... 5
1.3 Safety Symbols ......................................... 5
1.4 Nomenclature .......................................... 6
1.5 Specifications .......................................... 6
1.6 Disclaimer ............................................ 7
1.7 Safety Considerations ...................................... 7
1.8 Limited Warranty ........................................ 8
1.9 Repairing the Objective Heater Universal – Silver Line .................. 9
1.10 Waste Disposal – WEEE/RoHS Compliance Statement .................. 9
1.10.1 EU Directive WEEE ................................... 9
1.10.2 EU Directive RoHS ................................... 10
1.11 Regulatory Statement ...................................... 11
2 Intended Use 12
3 Principle 12
4 Equipment 13
5 Operation 14
5.1 Installation and Connection of the Objective Heater Universal – Silver Line . . . . . . 14
5.2 Emergency Release Mechanism ................................ 16
5.3 Temperature Adjustment of the Objective Heater Universal – Silver Line ........ 16
Version 1.0 (June 1, 2022) 4 Instruction Manual

Objective Heater Universal – Silver Line
1 Preamble
1.1 Introduction
1.2 Introduction
This manual is your guide to using the Objective Heater Universal – Silver Line for cell culture ex-
periments on an optical microscope. It instructs first-time users on how to use the instrument, and
serves as a reference for experienced users.
Before using the Objective Heater Universal – Silver Line, please read this instruction manual care-
fully and make sure that the contents are fully understood. This manual should be easily accessible to
the operator at all times during instrument operation. If this manual gets lost, see the online version
To ensure safe operation, the Objective Heater Universal – Silver Line must only be operated with
the supplied components and according to the instruction manual.
For Research Use Only! Not for use in diagnostic procedures.
The Objective Heater Universal – Silver Line (#12170) can be used with the Heating System Slide/Dish
– Silver Line (product numbers 12110, 12720, 12722, 12111) and the Heating System 4 Slides – Silver
Line (product numbers 12130, 12131).
1.3 Safety Symbols
Note that the signal words WARNING,CAUTION and NOTE have specific meanings in this man-
ual. Do not proceed beyond a signal word until you have performed the indicated actions. Warning
messages in the text are displayed in a gray shaded box. Please see section ?? for general safety
considerations.
WARNING – A potentially hazardous situation which, if not avoided, could result
in serious injury or even death.
CAUTION – A potentially hazardous situation which, if not avoided, could result in
minor or moderate injury. It is also used to alert against damaging the equipment or
the instrument.
NOTE – Additional information to help achieve optimal instrument and assay per-
formance.
Symbols on the product identification label and back panel of the device:
CE Marking: This symbol indicates the product’s compliance with EU legislation.
This label is positioned on the back of the device and prompts you to read the manual
before using the device.
Product disposal: The symbol indicates that this product must be recycled/disposed
of separately from other household waste. See page 9for details.
Instruction Manual 5 Version 1.0 (June 1, 2022)

Objective Heater Universal – Silver Line
1.4 Nomenclature
For better readability, the Objective Heater Universal – Silver Line is hereafter abbreviated and re-
ferred to as “Objective Heater” in body text and figure captions. The Objective Heater consists of the
following three components:
Flexible heating unit Cable Velcro®fastener
1.5 Specifications
Table 1: Specifications of the Objective Heater Universal – Silver Line
Electrical Specifications
Overvoltage category III
Input line voltage DC 24 V, 2 A, 48 W
Operating Conditions
Operating site Indoor use only
Operating temperature 18–30°C/64–86°F (min 5°C/9°F less than set tempera-
ture)
Humidity 80% relative humidity (RH) up to 31°C/87°F
30% relative humidity (RH) up to 40°C/104°F
Operating altitude max. 2000 m (atmospheric pressure 800–1060 hPa/
11.6–15.4 psi)
Storage conditions -5–50°C/23–122°F, humidity <60% relative humidity
(RH)
Outer Dimensions and Characteristics
Length of flexible heating unit 12 cm
Height of flexible heating unit 2 cm
Length of cable 232.5 cm
Weight of heating unit including cable 110 g
Fit With Microscope Objectives
Diameter of Objectives ∼2.5–4.5 cm
Version 1.0 (June 1, 2022) 6 Instruction Manual

Objective Heater Universal – Silver Line
Table 1: (continued)
Compatibility With Temperature Controllers and Temperature Control Range
Compatibility ibidi Temperature Controller – Silver Line
Temperature control range Ambient temperature (min. 18°C/64°F) to 45°C/113°F
Recommended temperature settings See Section 5.3
NOTE – The Objective Heater is only compatible with the ibidi Temperature Controller –
Silver Line, hereafter abbreviated and referred to as ”Temperature Controller”.
1.6 Disclaimer
• ibidi shall not be held liable, either directly or indirectly, for any damage incurred as a result of
product use.
• The contents of this manual are subject to change without notice for product improvement.
• This manual is considered complete and accurate at publication.
• This manual does not guarantee the validity of any patent rights or other rights.
• If an ibidi software program doesn’t function properly, this may be caused by a conflict from
another program operating on the computer. In this case, take corrective action by uninstalling
the conflicting product(s).
• ibidi is a registered trademark of ibidi GmbH in Germany and other countries.
1.7 Safety Considerations
WARNING
• Only operate the Objective Heater with the supplied components and the Temperature Con-
troller.
• Only use the cables and plugs delivered with the Objective Heater. The power plug of the
control unit must be inserted in an outlet with a ground (earth) contact.
• Do not replace detachable power cables with inadequate specifications power cables. By vio-
lating these instructions you risk electric shock and fire.
• Do not operate the Objective Heater under conditions that pose a risk of explosion, implosion,
or the release of gases.
Instruction Manual 7 Version 1.0 (June 1, 2022)

Objective Heater Universal – Silver Line
• Do not place flammable solids, liquids, gases, or gas outlets near the Objective Heater (e.g.,
matches, ethanol, propane gas, solvents). Do not bring these products in contact with any other
component of the system either.
• Do not operate a damaged Objective Heater. If the Objective Heater seems to be damaged,
contact [email protected].
• Only operate the Objective Heater properly installed to a microscope objective.
• Some accessible parts of the Objective Heater can reach temperatures up to 65°C. Avoid touch-
ing the temperature-controlled parts of the system when you have set the Temperature Con-
troller to high temperatures.
CAUTION
• Not all objectives/lenses tolerate heat! Please check with the manufacturer of your objective if
it can be heated.
• Ensure that the external power supply is easily accessible. The Objective Heater must be in-
stalled in a manner such that none of its components hinders access to the external power
supply.
• Immediately replace damaged cords, plugs, or cables to avoid the risk of personal injury or
damage to the instrument.
• Only ibidi technical staff and technical staff instructed by ibidi are permitted to open and ser-
vice the Objective Heater.
• The Objective Heater should not come in contact with moisture. If the housing is damaged, the
external power supply should not be used.
• Avoid strong magnetic fields and sources of high frequency. The Objective Heater might not
function properly when located near a strong magnetic field or high frequency source.
• Avoid vibrations from vacuum pumps, centrifuges, electric motors, processing equipment, and
machine tools.
• Avoid dust and corrosive gas. Do not install the Objective Heater where it could be exposed to
high levels of dust or outside air or ventilation outlets.
• Install the Objective Heater in a location that enables easy access for maintenance.
• Do not place heavy objects on the Objective Heater and do not fold the Objective Heater.
1.8 Limited Warranty
Products manufactured by ibidi, unless otherwise specified, are warrantied for a period of one year
from the date of shipment to be free of defects in materials and workmanship. If any defects in the
product are found during this warranty period, ibidi will repair or replace the defective part(s) or
product free of charge.
Version 1.0 (June 1, 2022) 8 Instruction Manual

Objective Heater Universal – Silver Line
This warranty does not apply to defects resulting from the following:
1. Improper or inadequate installation.
2. Improper or inadequate operation, maintenance, adjustment, or calibration.
3. Unauthorized modification or misuse.
4. Use of consumables, disposables, and parts not supplied by an authorized ibidi distributor.
5. Corrosion due to the use of improper solvents, samples, or due to surrounding gases.
6. Accidents beyond ibidi’s control, including natural disasters.
This warranty does not cover consumables, such as cell culture chambers and dishes, tubes, fluidic
connectors, reagents, etc.
The warranty for all parts supplied and repairs provided under this warranty expires on the warranty
expiration date of the original product.
1.9 Repairing the Objective Heater Universal – Silver Line
and provide the model name and serial number of your system.
CAUTION Do not try to repair the Objective Heater by yourself. Disassembly of the Objec-
tive Heater is not allowed. Disassembly poses a risk of personal injury or damage to the devices.
Contact ibidi technical support if there is a need to disassemble a device.
1.10 Waste Disposal – WEEE/RoHS Compliance Statement
The European Union (EU) has enacted two directives, the first on product recycling (Waste Electrical
and Electronic Equipment, WEEE) and the second on limiting the use of certain substances (Restric-
tion on the use of Hazardous Substances, RoHS).
1.10.1 EU Directive WEEE
The Objective Heater Universal – Silver Line must be disposed of in compliance with the WEEE
Directive 2012/19/EC.
Instruction Manual 9 Version 1.0 (June 1, 2022)

Objective Heater Universal – Silver Line
This symbol on the product is in accordance with the European Union’s Waste Electrical and Elec-
tronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/dis-
posed of separately from other household waste. It is the end user’s responsibility to dispose of this
product by taking it to a designated WEEE collection facility for the proper collection and recycling of
the waste equipment. The separate collection and recycling of waste equipment will help to conserve
natural resources and protect human health and the environment. For more information about recy-
cling, please contact your local environmental office, an electrical/electronic waste disposal company
or distributor where you purchased the product.
1.10.2 EU Directive RoHS
RoHS conformity is declared in the EU-conformity in Section 1.11.
Version 1.0 (June 1, 2022) 10 Instruction Manual
Indice
Altri manuali ibidi Attrezzature da laboratorio
Manuali Attrezzature da laboratorio popolari di altre marche

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manuale utente

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manuale utente

NI
NI PXI-5422 Manuale

Collomix
Collomix Aqix Manuale utente

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manuale utente

Ocean Insight
Ocean Insight FLAME-NIR+ Manuale utente