ICP DAS USA IR-712 Manuale utente

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012)
User Manual v1.1
www.icpdas.com
IR-712
Universal IR Learning Remote Module

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 1
Warranty
All products manufactured by ICP DAS are under warranty regarding
defective materials for a period of one year from the date of delivery to the
original purchaser.
Warning
ICP DAS assumes no liability for damages resulting from the use of
this product. ICP DAS reserves the right to change this manual at any time
without notice. The information furnished by ICP DAS is believed to be
accurate and reliable. However, no responsibility is assumed by ICP DAS
for its use, or for any infringements of patents or other rights of third
parties resulting from its use.
Copyright
Copyright 2012 by ICP DAS. All rights are reserved.
Trademark
The names used for identification only may be registered trademarks
of their respective companies.

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 2
Contents
1. Introduction .......................................................................................3
1.1 Features .................................................................................................. 4
1.2 Applications ............................................................................................. 4
2. Hardware ...........................................................................................5
2.1 Specifications .......................................................................................... 5
2.2 Appearance ............................................................................................. 6
2.3 Pin assignments ...................................................................................... 7
2.4 Wire connection....................................................................................... 8
2.4.1 RS-232 connection........................................................................... 8
2.4.2 RS-485 connection........................................................................... 9
2.4.3 Jack Plug of IR Output Cable ......................................................... 10
2.4.4 Power Connection.......................................................................... 10
2.5 Watchdog Timer .....................................................................................11
2.6 Firmware Update DIP Switch ................................................................ 12
2.6.1 Update Firmware Mode.................................................................. 12
2.6.2 Firmware Operation Mode.............................................................. 13
2.7 LED Indicators....................................................................................... 14
3. Software...........................................................................................15
3.1 The Configuration Tool– IR-712 Utility................................................... 15
3.2 IR-712 Utility.......................................................................................... 16
3.2.1 Menu .............................................................................................. 16
3.2.2 Open/Close COM port.................................................................... 20
3.2.3 Set Device & IR Command Quantity .............................................. 20
3.2.4 Test and Save Learned IR Commands .......................................... 22
3.2.5 Test IR commands in IR-712 .......................................................... 24
4. Learning IR command Example.....................................................25
4.1 IR-712 Communication settings ............................................................ 25
4.2 Set the Devices and IR commands Quantity ......................................... 26
4.3 Learn and Test IR Commands............................................................... 27
4.4 Saving the Learned IR Commands to a File.......................................... 28
4.5 Download the IR Learning Commands to the IR-712 ............................ 28
4.6 Test the IR commands saved in the IR-712........................................... 28
4.7 Load the IR Learning Commands from a File........................................ 29
4.8 Load IR Learning Commands from the IR-712...................................... 29
5. Modbus Registers for IR-712..........................................................30
6. Technical support ...........................................................................31

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 3
1. Introduction
The Intelligent Home and Building Automation are becoming the hot topics recently in
the world. Many countries are devoted to development and promotion in this field.
There are many kinds of consumer electronics and home appliances in the market
applying the IR remote control function because of its mature technology and low cost.
However, these appliances are usually equipped with their own remote controls using
diverse IR protocols which are not unified to a standard. If these IR commands of
different appliances can be collected and integrated to the control interfaces, it is
possible to implement the automation application for a better living experience.
IR-712 is a universal IR learning remote module which can learn IR remote commands
of diverse electronic devices. The learning commands can be stored in the module or
saved to a file. IR-712 supplies 2 IR output channels for individual or simultaneous
control on multiple devices. The accompanied RS-232 and RS-485 interfaces with
Modbus/RTU protocol provide more flexible expansion and control on the module.
Besides, IR-712 software utility provides users with easy configuration, learning, test
and storage of IR commands. As a replacement of IR remote controls and a module
that can be easily integrated with Modbus master devices (e.g. PAC, PLC, PC… etc.),
IR-712 is well-suited for smart home and building automation.
Fig. 1-1: IR-712 application architecture.

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 4
1.1 Features
[IR-712]
2IR output channels for controlling multiple devices.
1 IR learning input.
Supports 6 learning IR carrier frequencies: 32.768、36、37.037、38、40 and
56 kHz.
Can learn and store 36 IR commands.
Supports RS-232 and RS-485 serial interface.
Supports Modbus/RTU protocol (FC06 and FC16).
Assignable Modbus Network IDs: 1 ~ 247
Baud rate settings: 9600, 19200, 38400, 57600 and 115200 bps.
Configurable NONE / ODD / EVEN parity and 1 or 2 stop bits.
Provides transmitting/learning and power indication LEDs.
Built-in Watchdog.
RoHS Compliance.
[Utility]
Configuration of IR command quantity.
IR commands learning and testing.
Save IR learning commands to files.
Get / Set IR learning commands from / to IR-712.
Reference to Modbus commands.
Set / Reset basic settings of IR-712.
Supports Windows XP, Vista and Windows 7 with .NET framework 4.0.
1.2 Applications
Home Entertainment Devices
Video Conferencing System
Surveillance System
e-Classroom service
Lighting Scenario Control
Home and Building Automation

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 5
2. Hardware
2.1 Specifications
IR-712
IR Interface
IR Output Ch.
2 channels with 3.5 mm audio jack
IR Input Ch.
1 channel. Supports 6 IR carrier frequencies: 32.768, 36, 37.037, 38, 40, 56
kHz.
UART Interface
Connector
8-pin (RS-485, RS-232, power) screw terminal connector
COM1
RS-232 (TxD, RxD, GND)
COM2
RS-485 (DATA+, DATA-)
Baud Rate (bps)
9600, 19200, 38400, 57600, 115200
Protocol
Modbus/RTU (slave)
LED Indicator
LED
2 LEDs: TR (IR Transmitting)/LN (IR Learning) and PWR (Power)
Power
Power Supply
+10 ~ +30 VDC
Power Consumption
1.8 W Max (OP mode)
DIP Switch
FW (firmware update mode) / OP (firmware operation mode)
Mechanism
Installation
DIN-Rail
Dimensions
52 mm x 93 mm x 27 mm (W x H x D)
Environment
Operating Temperature
-25 ℃~ +80 ℃
Storage Temperature
-30 ℃~ +85 ℃
Humidity
10 ~ 90% RH, non-condensing

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 6
2.2 Appearance
Fig. 2-1: The front view of the IR-712.

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 7
2.3 Pin assignments
●IR output channels and learning input
IR Output 1 ~ 2:3.5 mm audio jack
Fig. 2-2: IR output 3.5 mm audio jack and learning input hole (front/bottom view).
●Communication terminal
Table 2-1: IR-712 terminal pin assignments
Screw terminal connecter
Pin No.
Description
Interface
1
DATA+
RS-485
2
DATA-
3
GND (ground)
RS-232
4
TxD
5
RxD
6
N/A
N/A
7
GND (ground)
Power
8
+Vs
Fig. 2-3: Screw terminal connector

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 8
2.4 Wire connection
The IR-712 supports 2 serial communication interfaces: RS-232 and RS-485 ports.
Only one interface can be used at the same time. The default interface is RS-232 port.
2 IR outputs at the bottom are 3.5 mm audio jacks.
Note: The IR-712 utility can help users to change the serial communication port (RS-
232/RS-485). The TR/LN LED can indicate which port is used in the beginning 3
seconds after power-cycling the IR-712.
2.4.1 RS-232 connection
The wire connection for IR-712’s RS-232 port is shown in Fig. 2-4.
Fig. 2-4: RS-232 wire connection.
Please refer to Fig. 2-6 if the RS-232 connection cable (e.g. CA-0910, Fig. 2-5) is
applied. If there is no DB9 serial port on the host PC, it is recommended to use USB to
RS-232 converter (e.g. I-7560 or I-7561) to extend the serial port.
Fig. 2-5 RS-232 connection cable (CA-0910)

IR-712 Universal IR Learning Remote Module (Ver. 1.1, May/02/2012) 9
Fig. 2-6: Wire connection between PC and IR-712 using CA-0910.
2.4.2 RS-485 connection
The RS-485 wire connection between the IR-712 and RS-485 host device is depicted
in Fig. 2-7.
Fig. 2-7: RS-485 wire connection.
The USB to RS-485 converter (tM-7561 or I-7561) is recommended for the host PC to
test and configure the IR-712.