ICPDAS RS Series Manuale utente

TDRS0602
TM
RS Series Quick Start
Industrial Redundant Ring Switch
Version 1.0
This document applied to models of
RS-30 5, RS-405/8, RSM-405/8
July 11, 2006
Please print in double side

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS4050601 i
Document Control
Date Author Version Description
July 1st, 2006 KC Chen 1.0 First draft

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS4050601
ii
Copyright & Trademarks
All rights reserved. No part of this publication may be
reproduced, stored in a retrieval system, or transmitted in
any form or by any means, whether electronic, mechanical,
photo copying, recording or otherwise, without the prior
written permission of the publisher.
The names used for identification only may be registered
trademarks of their respective companies.
Copyright©ICP DAS Co., Ltd., All Rights Reserved.

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS4050601 iii
Disclaimer
Limited Warranty
All products manufactured by ICP DAS are warranted against
defective materials for a period of one year from the date of
delivery to the original purchaser. During this period, if a
customer is unable to resolve a product problem with ICP DAS
Technical Support, a Return Material Authorization (RMA) will
be issued. If the product is not under warranty, the customer
may have ICP DAS repair the unit on a fee basis or return it.
This warranty is voided if the customer uses the product in
an unauthorized or improper way, or in an environment for
which it was not designed.
Standards
The Ring Switch meets the following standards:
zEMC immunity - IEC61326-1, IEEE C37.90
zEMI emissions - FCC part 15, ICES 003, EN55022; Class B
zElectrical safety - UL 508, CSA C22/14; EN61010-1 (IEC1010)
Warning
ICP DAS assume no liability for damages consequent to the
use of this product. ICP DAS reserves the right to change this
manual at any time without notice. The information furnished
by ICP DAS is believed to be accurate and reliable. However,
no responsibility is assumed by ICP DAS for its use, nor for
any infringements of patents or other rights of third parties
resulting from its use.
Safety
Install the Real Time Ring Switch in accordance with local and
national electrical codes.
Lightning Danger: Do not work on equipment during periods of
lightning activity.
Do not connect a telephone line into one of the Ethernet RJ45
connectors.

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS4050601
iv
Contents
Document Control......................................................................................i
Copyright & Trademarks............................................................................ii
Disclaimer..................................................................................................iii
Limited Warranty.......................................................................................................iii
Standards .................................................................................................................iii
Warning ....................................................................................................................iii
Safety........................................................................................................................iii
Contents....................................................................................................iv
Appearance...............................................................................................1
Dimensions...............................................................................................................2
Front Panel............................................................................................................... 3
On Case Quick Guide............................................................................................... 4
Hardware Installation.................................................................................5
DIN-Rail Mounting Installation..................................................................................6
Wall-Mounting Installation ........................................................................................ 7
Connecting Input Power ........................................................................................... 8
Connecting Output Relay ......................................................................................... 9
Connecting Ethernet Ports .....................................................................................10
Connecting Fiber Ports (only for models with fiber port)........................................ 11
Configuration.............................................................................................12
One Ring Topology.................................................................................................13
Two Rings Coupling................................................................................................14
Two Rings Coupling with Two Phase Recovering..................................................15
Service Information....................................................................................16
On-line support.......................................................................................................16
Contact Worldwide.................................................................................................. 16
Appendix A................................................................................................a
Specifications............................................................................................................a

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS0602 1
Dimensions
Front Panel
On Case Quick Guide
Appearance
RS Series come with three form factors. One is stand alone with
industrial plastic case. The second one is stand alone with aluminum
case. And the other is modulized for ICPDAS PAC Series controllers
with industrial plastic case.
Overview
The RS Series is designed for easy installation, configuration and
maintenance. For hardware installation, we provide both easy DIN rail
mounting and wall mounting modes. To establish a simple redundant
ring, only 2 jumpers on the front panel to set to form a ring. It does
not depend on web configuration interface, neither a management
server.
All of connectors are well arranged on the front panel, so it is easier
to stack with other devices and to maintain in a small installation
space.

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS0602
2
Dimensions
48.01
35.40
48.01
Left Side View Front View
Back View
Right Side View
Bottom View
Top View
131.42 110.11
72.59
10.65
3.50
3.50
95.20
103.40
40.00
16.30 16.30
122.92
Ø4.50
Auxiliary View

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS0602 3
Front Panel
➊ Master switch LED indicator
❷ Power 1 LED indicator
❸ Power 2 LED indicator
❹ Switch jumper block
1. Ring / Normal Switch selecting jumper
2. Reset to default jumper
3. TPRT master setting jumper
4. Ring protocol selecting jumper
5. Enabling Ring 1 jumper
6. Enabling Ring 2 jumper
❺ Rotate jumper block
❻ Serial line via Ethernet port
❼ Terminal block
1. Frame Ground(F.G.)
2. Relay (R.NO)
3. Relay (R.COM)
4. Power 2 Grounding (GND)
5. Power 2 (PWR2)
6. Power 1 Grounding (GND)
7. Power 1 (PWR1)
❽ Interconnection port for 2
phase recovering coupling
❾ RJ-45 Ethernet ports

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS0602
4
On Case Quick Guide
The simple description of DIP and Rotate jumpers setting value, Quick Config Guide, has
been printed on both right and left hand side of front panel. After acquainted with RS
Series features, field engineers could deploy switches quickly by referencing Quick
Config Guide.

Industrial Redundant Ring Switch – RS Series Quick Start
TDRS0602 5
DIN-Rail Mounting
Installation
Wall-Mounting Installation
Connecting Input Power
Connecting Output Relay
Connecting Ethernet Ports
Connecting Fiber Ports
Hardware Installation
For hardware installation, we provide both easy DIN rail mounting
and wall mounting modes.
Overview
RS Series support redundant power, output relay and enhanced
isolation to make device much robust. With ICP DAS patent DIN-Clip®
design, the installation is just as easy as plugging power cord into
outlet.