IDEAL 61-847 Manuale utente

1
Instrucciones en español adentro / Instructions en français à l’intérieur
61-847
Dual Laser Targeting
Infrared Thermometer
IDEAL®Test and Measurement

2
Table of Contents
Introduction................................................................. 3
Contacting IDEAL INDUSTRIES, INC .................................... 3
Safety Information......................................................... 4
Warnings.............................................................................................. 4
Cautions............................................................................................... 4
Symbols............................................................................................... 5
Operation................................................................ 6-21
Identification and description of operating controls and
functions ..........................................................................................6-7
Operating Features............................................................................. 12
Meter Operation ............................................................................12-16
Power On .................................................................................... 12
Functions Setting...................................................................12-14
MAX/MIN/AVG/DIF Readings ..................................................... 13
Hi/Lo Temperature Alarms........................................................... 13
Emissivity Setting........................................................................ 13
Temperature Unit Setting............................................................. 14
Lock Measurement Setting.......................................................... 14
Hi and Lo Alarm Limit Setting..................................................... 14
Backlight/Laser Pointers On/Off.................................................. 15
Lock Measurement (APO) Description ...................................15-16
Emissivity Description................................................................. 17
Accuracy Diagram....................................................................... 17
Spot Size to Distance .................................................................. 18
Field of View ............................................................................... 19
Functions Operation Table.............................................................20-21
Functions Indication Table ................................................................. 20
Measurement Specifications........................................... 22
Environmental Specifications.......................................... 22
Mechanical Specifications ............................................. 23
EMC / EMI ................................................................. 23
FCC .................................................................. 23
Safety .................................................................. 23
Maintenance and Service .............................................. 24
Disposal and Warranty.................................................. 25

2 3
Table of Contents Introduction
The IDEAL 61-847 Dual Laser Targeting Infrared Thermometer (IRT) is a non
contact temperature sensing meter. Its dual lasers define the outside edges
of the area whos temperature will be measured. The IRT displays the actual
measurement as well as 4 selectable additional measurements. HI and LO
alarms and emissivity are all user programmable.
Eye damage or personal injury hazard. Follow all safety procedures. Read and
fully understand the instruction manuals prior to using this product. Failure to
comply can result in serious injury.
WARNING
LASER
2
Contacting IDEAL INDUSTRIES, INC.
To contact IDEAL INDUSTRIES, INC., call one of the following telephone
numbers:
IDEAL Industries USA Customer Service
• Phone Number: 800-435-0705
IDEAL Industries Canada Customer Service
• Phone Number: 905-683-3400
IDEAL Industries EMEA
• Phone Number: +44 (0)1925 444 446
IDEAL Industries Australia
• Phone Number: +61 3 9562 0175
Or visit the IDEAL Electrical Website at www.idealind.com
To register your product, find manuals, watch videos, simply scan
this QR code.
Introduction................................................................. 3
Contacting IDEAL INDUSTRIES, INC .................................... 3
Safety Information......................................................... 4
Warnings.............................................................................................. 4
Cautions............................................................................................... 4
Symbols............................................................................................... 5
Operation................................................................ 6-21
Identification and description of operating controls and
functions ..........................................................................................6-7
Operating Features............................................................................. 12
Meter Operation ............................................................................12-16
Power On .................................................................................... 12
Functions Setting...................................................................12-14
MAX/MIN/AVG/DIF Readings ..................................................... 13
Hi/Lo Temperature Alarms........................................................... 13
Emissivity Setting........................................................................ 13
Temperature Unit Setting............................................................. 14
Lock Measurement Setting.......................................................... 14
Hi and Lo Alarm Limit Setting..................................................... 14
Backlight/Laser Pointers On/Off.................................................. 15
Lock Measurement (APO) Description ...................................15-16
Emissivity Description................................................................. 17
Accuracy Diagram....................................................................... 17
Spot Size to Distance .................................................................. 18
Field of View ............................................................................... 19
Functions Operation Table.............................................................20-21
Functions Indication Table ................................................................. 20
Measurement Specifications........................................... 22
Environmental Specifications.......................................... 22
Mechanical Specifications ............................................. 23
EMC / EMI ................................................................. 23
FCC .................................................................. 23
Safety .................................................................. 23
Maintenance and Service .............................................. 24
Disposal and Warranty.................................................. 25

4
Warning -Identifies conditions and actions that
could result in serious injury if the hazard is realized.
Caution - Identifies conditions and actions that could result in meter
damage or an incorrect reading if the hazard is realized.
Safety Information
Eye damage or personal injury hazard. Follow all safety procedures. Read and fully
understand the instruction manuals prior to using this product. Failure to comply
can result in serious injury.
• Choking Hazard, Small Parts. Keep Away from Children. This is not a
toy. It is not for use or play by children. Keep Away from Children. Failure to
do so can result in serious injury.
• Do not point the laser directly at people or animals.
• Do not look at the laser directly or through other optical tools (telescope,
microscope, binoculars) or reflected laser light.
• Do not come in contact with high temperature surfaces when making
measurements.
• Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
• Do not use the thermometer in an environment close to flammable or
explosive materials.
• Cancer and Reproductive Harm - www.P65Warnings.ca.gov
WARNING
CAUTION
Laser
2
Laser
2
Laser
2
LASER RADIATION DO NOT STARE INTO BEAM
OUTPUT <1mW COMPLIES WITH EN60825-1:2014
Identifies conditions and actions that could result in meter damage or an incorrect
reading if the hazard is realized.
• Do not disassemble or modify the thermometer or laser.
• This unit has no serviceable parts.
• To avoid false readings, replace the batteries as soon as the low battery
indicator ( ) appears.
• Do not use without the batteries correctly in place and the battery door
closed and secured.
• Inspect the case before using the thermometer. Do not use the thermometer
if it appears damaged. Look for cracks or missing plastic.
• Using the thermometer around steam, dust, or environments with large
temperature fluctuations may lead to inaccurate temperature measurement.
• To ensure measurement accuracy, please place the thermometer in the
measurement environment for 30 minutes before using.
• Avoid keeping the thermometer near high temperature environment for
long periods.
• Clean the case and accessories with a damp cloth and mild detergents only.
Do not use abrasives or solvents. Make sure the meter is completely dry
before use.

4 5
Symbols & Descriptions
LASER RADIATION DO NOT STARE INTO BEAM
OUTPUT <1mW COMPLIES WITH EN60825-1:2014
Identifies conditions and actions that could result in meter damage or an incorrect
reading if the hazard is realized.
• Do not disassemble or modify the thermometer or laser.
• This unit has no serviceable parts.
• To avoid false readings, replace the batteries as soon as the low battery
indicator ( ) appears.
• Do not use without the batteries correctly in place and the battery door
closed and secured.
• Inspect the case before using the thermometer. Do not use the thermometer
if it appears damaged. Look for cracks or missing plastic.
• Using the thermometer around steam, dust, or environments with large
temperature fluctuations may lead to inaccurate temperature measurement.
• To ensure measurement accuracy, please place the thermometer in the
measurement environment for 30 minutes before using.
• Avoid keeping the thermometer near high temperature environment for
long periods.
• Clean the case and accessories with a damp cloth and mild detergents only.
Do not use abrasives or solvents. Make sure the meter is completely dry
before use.
SYMBOL DESCRIPTION
Warning or Caution
Laser Radiation Warning
Laser Eye Hazard
Laser Class 2 Warning- Class 2 lasers are considered
safe for normal operation. Class 2 lasers’ output power is
below 1 milliwatt. All Class 2 lasers emit visible light only.
Choking Hazard
Low Battery Indicator
LCD Liquid Crystal Display
Do not dispose of this product as unsorted municipal
waste. It must be properly disposed of in accordance
with local regulations. Please see www.epa.gov or
www.erecycle.org for additional information.
Conforms to applicable North American Safety Standards
Conforms to applicable Australian Safety Standards
Conforms to European Directives
LASER
2

6
Identification and Description of Operating
Controls and Functions for the Dual Laser
Targeting Infra Red Thermometer:
1. LCD Screen
2. Function Buttons
3. Lanyard Attach Point
4. Industrial Grip Battery Cover
5. Trigger (Turns IRT On)
6. Laser Aiming Emitters
7. IR Lens
8. Standard Tripod Mount Thread
Operation

6 7
1. LCD Screen
2. Function Buttons
3. Lanyard Attach Point
4. Industrial Grip Battery Cover
5. Trigger (Turns IRT On)
6. Laser Aiming Emitters
7. IR Lens
8. Standard Tripod Mount Thread
Operation
4
1
3
6
7
2
5
6
8

8
1. HI LO/Decrease Button
2. Laser Backlight On Off Button
3. SET Button
4. Mode/Increase Button
5. LCD Display
1
2
3
4
5
1. Laser Target Emitters
2. Infra-Red Sensor
3. Trigger
4. Battery Cover Screw

8 9
1. HI LO/Decrease Button
2. Laser Backlight On Off Button
3. SET Button
4. Mode/Increase Button
5. LCD Display
1. Laser Target Emitters
2. Infra-Red Sensor
3. Trigger
4. Battery Cover Screw
1
2
3
4
Laser
2
Laser
2

10
1. Lock Measuring Indicator
2. HI Alarm value is programmed
3. Audible Beep On or Off
4. OK indicator. Temp is within programmed limits
5. LO Alarm value is programmed
6. Laser Pointer is On or Off
7. Low Battery Indicator
8. Degrees Displayed in F or C
9. Main Display
10. Secondary Display
11. Secondary Display Legend (MODE Button)
12. Actively scanning and updating in real time.
13. HOLD the last reading in the display
14. Emissivity Setting
Display and Functions Indication Diagram
MAX MIN
AVG DIF
C F
HOLD SCAN
OK LOHI
=
3
1 2 3 4 5 6
14
13
12
7
8
9
10
11
Indice
Lingue:
Altri manuali IDEAL Termometro