JEICO JREMO 10EX Manuale utente

O&M MANUAL
JREMO 10EX
REMOTE CONTROL
www.jeico.com

JEICO® INDUSTRIAL REMOTE CONTROLLER
MODEL JREMO 10EX JREMO 10EX
Serial No.
Channel No.
Lot No.
JREMO® Remote Controllers must be handled, installed,
operated, and maintained by (an) authorized
and (a) qualied person(s), and
Upon the above condition guaranty period from the date of
(delivery, installation, inspection)
shall be one calendar year.
Subject to conrming defects not caused by improper installation,
improper operation and/or insucient
maintenance, unauthorized modication, ignorance of
environmental specications, or improper interfacing,
irresistible forces such as war(s), strike(s), Act(s) of God, and so on;
all such the defects shall be treated as in no warranty.
WARRANTY

03
JREMO 10EX
Industrial radio remote controller
Contents
PRECAUTIONS ………………………………………………… 04
CHAPTER I. GENERAL SPECIFICATIONS …………… 06
1.1. COMMON SPECIFICATION ……………………………… 06
1.2 Transmitter (Tx) …………………………………………… 06
1.3 RECEIVER (Rx) ……………………………………………… 06
1.4 Model Suxing …………………………………………… 06
CHAPTER 2. JREMO 10EX Standard Set …………… 07
2-1 Standard set ……………………………………………… 07
2-2 CONTROL CONTACTS WIRE DIAGRAMS ……………… 08
CHAPTER 3. INSTALLATION & FUNCTION SETTING ………
10
3-1 CAUTIONS FOR INSTALLATION
………………………………
10
3-2 HOW TO INSTALL JREMO® SERIES TX
……………………
11
3-3 HOW TO INSTALL JREMO® SERIES RX
……………………
12
3-4 HOW TO START & USE PASSWORD(PWD)
………………
13
CHAPTER 4. MAINTENANCE
……………………………………
14
4-1 STANDARD OPERATION
…………………………………………
14
4-2 FUSES
…………………………………………………………………
14
CHAPTER 5. TROUBLESHOOTING
…………………………
15
5-1 SELF DIAGNOSIS (LED SIGNAL ERROR MESSAGE)
……
15
5-2 LED Diagnosis
………………………………………………………
15
5-3 Troubleshooting
……………………………………………………
16
APPENDIX Ⅰ - 433 BAND FREQUENCY TABLE
…………………
17
APPENDIX Ⅱ - 447 & 173 & 429 FREQUENCY TABLE
…………
18
APPENDIX III - OPTIONAL ACCESSORIES
…………………………
19

04
JREMO 10EX
Industrial radio remote controller
A. ANNOUNCEMENT
▪ This O&M Manual is for JREMO® 10EX and the specification is referred to
Chapter 1.
▪ Before installation and operation look through this manual and make sure
having a full acknowledgement of this manual.
▪ JREMO® series' remote controllers compose a High-Tech systemized, and a
full knowledge of this manual is a must in advance of installation as well as
operation of this remote controllers.
▪ Do not try to dismantle or unscrew JREMO® series except a skilful, an expert,
and an authorized.
▪ This manual is for reference and good for installation and for maintenance,
for better functions and qualities it may be changed, modified, revised
without notice in advance. For more details consult an adjacent agent and/
or supplier.
▪ Each and all the JREMO® series' remote controller is tested under severe
condition and passed without any default found at factory and is ready for
an immediate use for a normal/insufficient condition or so, however, in an
emergency and/or in an any dangerous possibility, do not use.
▪ After use switch off the main power of the equipment(ex. winch) and confirm
the receiver power off, and also confirm EMS button of the transmitter is in a
pressed down position.
▪ When not in use stay the transmitter in a safety area and do not allow an
unauthorized to attempt to use it.
▪ Equipment(ex. winch) using this remote controller must have main relays,
limit switches, separate COM lines, and other appropriate devices for safety
operation.
▪ When metal container for receiver casing is used make sure Ground(GND) to
be sure connected to metal part of equipment(ex. winch).
▪ Do not use in a severe interfered area and/or lightening or so.
▪ Make sure power sources are correct.
▪ Power off and do not use during installation and/or maintenance so as to
avoid any electric shock or so.
▪ Do not try to copy, modify, or release this remote controllers without permis-
sion in advance by JEICO, such an action is illegal. JREMO® series' remote
controller have many international patents, certificates, and so on.
PRECAUTIONS

05
JREMO 10EX
Industrial radio remote controller
B. GENERAL CAUTIONS
▪ Operator must be healthy both physically and mentally.
▪ Even though this remote controller is versatile, durable, and good for outdoor
use try to avoid to contact directly by an excessive shock, pressure, wind,
snow, rain, ices, or sunlight, high temperature, humid, gas, and etc.
▪ During operation when found power is weak replace all the batteries with all
new AA batteries.
▪ When rechargeable batteries (however, it is not recommended because of
shorter life) are used, use of AA 1.2V Ni-MH 2,500 mAH or above.
▪ When not in use take out batteries from the transmitter and put aside in a
different area.
▪ In an emergency follow up the below emergency measures.
C. EMERGENCY MEASURES
JREMO® Series has designed for safety, meeting with various kind of emer-
gencies and for self-recovering. Billions of dierent I.D. code, Self-Diagnoses,
super qualied and isolated protection against voltage surges and/or inter-
feres, etc. are the basic integral functions for solving any unexpected accident
or trouble in an emergency. So when such an emergent function is detected,
JREMO® series will o the work immediately and stop all the function auto-
matically.
For emergency follow up the below procedure in advance and then call an
adjacent JEICO® agent and/or supplier for an emergency service.
1. Press EMS(Emergency Stop) Button. (red mushroom at top left)
2. O the rotary key and pull out the key. (green key at top right)
3. Power o receiver power. Power o main power of Equipment.
4. Inquire adjacent JEICO® agent and or supplier.
PRECAUTIONS
▪ Without notice in advance and within JEICO's discretion this manual may be
revised, added, and/or deleted for better use.

06
JREMO 10EX
Industrial radio remote controller
Chapter 1. GENERAL SPECIFICATIONS
1.1. COMMON SPECIFICATION
- Frequency Ranges & Channel Numbers
433 Bands : 433.050~434.7750 Mhz, 70 channels
447 Bands : 447.600~447.9875 Mhz, 32 channels
173 Bands : 173.025~173.7875 Mhz, 35 channels
429 Bands : 429.2500~429.7375Mhz, 40 channels
- I.D. Code : 232 (Over 4 Billion)
- Temperature : -10 ℃ ~ +60 ℃
- Remote Distance : 30 ~ 150 M.
- Ex Level : Ex Ib IIC T4
- Protection Grade : (Tx) IP55 / (Rx) IP66
- Case Construction : ANTISTATIC ABS
1.2 Transmitter (Tx)
- Modle : JREMO 10EX
- Batt. Power : 4 x 1.5 V Alkaline Batteries (LR6 AA Size)
- Type : Single or Double Push Button Type
- Size : 173 x 62 x 46 mm (L x W x H)
- Weight : Approx. 355/395/450 gr. (Batteries Incl.)
1.3 Receiver (Rx)
- Casing : RX3
- Power : AC110~440V, DC12~40V (OPT AC48V, DC 60V)
- Type : Remote Main Lamp Indication
- Ralay : AC =>“A” Contact, 250VAC/5A, 125VAC/10A
DC =>“A” Contact, 24VDC/15A, 120VAC/15A
- Size, mm : 90x152/215x105
- Weight, gr. : 950/1350/1220(Cable incl)
1.4 Model Suxing
Chapter 1.
GENERAL SPECIFICATIONS
JREMO 10EX A (RX3)
Model Name
Sux
RX Size(Normally not indicated)
Rx Casing Size
10EX
ASingle P/B RX3
BDouble P/B RX3
CU/D Creep RX3
DDouble P/B RX3
MMobile for DC Rx RX3
Model
Type

07
JREMO 10EX
Industrial radio remote controller
CHAPTER 2. JREMO 10EX Standard Set
2-1 STANDARD SET
CHAPTER 2. JREMO 10EX Standard Set
JREMO 10EX Standard Set comprises one transmitter and one receiver as following as a set
■ FUNCTIONS MODEL NAME RECEIVER
Single P/B : JREMO 10EX A ⇨ RX3 (26 Core Cable)
U/D Creep P/B : JREMO 10EX C ⇨ RX3 (26 Core Cable)
6 Double P/B : JREMO 10EX B ⇨ RX3 (26 Core Cable)
8 Double P/B : JREMO 10EX D ⇨ RX3 (26 Core Cable)
Single P/B For D.C. : JREMO 10EX M ⇨ RX3 (16 Core Cable)
A/B/C/D/M
193 x 62 x 46 mm
Approx. 395 gr.
Refer to page 11 for sux arr.
RX3
90 x 215 x 105 mm
Approx. 1,350 gr.
24(16 for “10EX M“) Core Cable
Tx
Rx3
Note : RX casing for JREMO 10EX may not be used in case internal
parts of RX to be placed in an Exp. Proof Box.

08
JREMO 10EX
Industrial radio remote controller
CHAPTER2. JREMO 10EX Standard Set
2-2 CONTROL CONTACT WIRE DIAGRAM
▪JREMO 10EX(10EX) A/B/C/D
Single & Double P/B AC Diagram
▪JREMO 10EX M
Single P/B DC Diagram
JREMO 10EX A~D JREMO 10EX M
RECEIVER RX3, 90 x 215 x 105 mm, approx. 1,350 gr.
CABLE 26 Core Cable 16Core Cable
0.75 Sq, 600VAC, approx. 1.7m long, numbered
RELAY 250VAC/5A
125VAC/10A 24VDC/15A
120VAC/15A
FUSE F1(1A) / F2(10A) 5A(F1) / 20A(F2,F3,F4)
20MM Column Fuse
INPUT POWER AC110~440V Core Cable DC 12~40V (opt. ~60V)

09
JREMO 10EX
Industrial radio remote controller
CHAPTER2. JREMO 10EX Standard Set
▪JREMO 10EX A+ ( a special JREMO 10EX sux model)
Standard Double P/B
U/D Creep
JREMO 10EX C
6 Double P/B
JREMO 10EX B
8 Double P/B
JREMO 10EX D
Single P/B
JREMO 10EX A
JREMO 10EX A+
JREMO 10EX M

10
JREMO 10EX
Industrial radio remote controller
CHAPTER 3. INSTALLATION & FUNCTION SETTING
3-1 CAUTIONS FOR INSTALLATION
1. Follow up all the safety rule of equipment (ex. crane)
2. Switch o the main power of equipment (ex. crane) in a rst action.
3. Install receiver where there will have any other obstructions.
4. Fix receiver rmly.
5. Use an optional external antenna in case receiver installs inside the
metal closed box or electrical panel.
6. Check safety devices of equipment(ex. crane) before installation and
conrm it is under utmost safety condition.
7. Do not try to install without gaining in skill for electrical circuit diagrams
and operation circuits of equipment(ex. crane), remote controller's func-
tions, etc for avoiding an unexpected accident, wrong functions, etc.
8. For avoiding any possible interferes install receiver far from motor
and transducer as following illustration :
9. Install receiver top outside of electrical control box and installation in
inside the control box is not a proper method.
CHAPTER 3. INSTALLATION & FUNCTION SETTING
RECEIVER
MOTOR TRANS
CABLE
Min. 3M DISTANCE
⇨
RECEIVER
E L E C T R I C A L
CONTROL BOX
E L E C T R I C A L
CONTROL BOX
ANTENNA RECEIVER
Indice