König HC-PS310N Manuale utente

HC-PS310N
Digital Personal Scale
BRUGERVEJLEDNING (s. 87)
VEILEDNING (s. 93)
ИНСТРУКЦИЯ (99 стр.)
KILAVUZ (s. 106)
INSTRUKCJA OBSŁUGI (str. 112)
MANUAL (p. 2)
ANLEITUNG (S. 8)
MODE D’EMPLOI (p. 15)
GEBRUIKSAANWIJZING (p. 22)
MANUALE (p. 29)
MANUAL DE USO (p. 35)
MANUAL (p. 42)
HASZNÁLATI ÚTMUTATÓ (o. 49)
KÄYTTÖOHJE (s. 55)
BRUKSANVISNING (s. 61)
NÁVOD K POUŽITÍ (s. 67)
MANUAL DE UTILIZARE (p. 74)
ΕΓΧΕΙΡΙΔΙΟ XPHΣHΣ (σελ. 80)

2
ENGLISH
Introduction
The digital personal scale is designed to accurately indicate body weight and fat. This scale
works on the principle of Bio-electrical Impedance Analysis (BIA). By measuring the electrical
resistance and the nal calculation of the constant values (age, height, sex, activity level) it is
possible to determine the percentage of body fat, body water and muscle percentage in the
body.
The scale is able to facilitate 10 persons.
In order to ensure accurate results users should enter the following personal parameters:
- Gender
- Height
- Age
• We recommend that you read this manual before using the scale.
• Keep this manual in a safe place for future reference.
The scale operates with 3x 1.5 V AAA batteries (not included).
Technical specications
Display: Digital LCD display
Capacity: 180 kg/396 lb
Graduation: 0.1 kg/0.2 lb/¼ lb
Body fat division: 0.1%
Water division: 0.1%
Age range for body fat: 6–100 years
Height range: 80–220 cm
Height unit: cm/ft-in
Memory: 10 persons
Weight units: Kilogram (kg)/Stone (st)/Pound (lb)
Dimensions: 32 x 32 x 2.5 cm
Weight: 2 kg
Safety precautions
• To avoid tipping the unit, do not stand on the corners of the platform.
• Do not use the scales if you have a pacemaker or other internal electronic medical device.
• Pregnant women should use the weight function only.
• Do not open the scale in the event of a malfunction. This product should only be opened
by a qualied technician.
• Do not expose the scale to high temperatures or humidity.
• Remove the batteries if they will not be used for a long period of time.

3
ENGLISH
Installation instructions
1. Battery compartment cover
2. Weight units selection button
Install the batteries
1. Open the battery cover (on the underside of the scale) by releasing the clip and lifting the
cover.
2. Insert the batteries.
)Be sure the polarity of the batteries is set properly.
3. Close the cover.
Select weighing mode
Switch the scale on (ON/OFF button).
Use the Weight units selection button (underside of scale) to select the weight units (kg/lb/
st).
Place the scale
Place the scale on a rm, at and even surface to ensure accuracy.

4
ENGLISH
User instructions
User instructions
1. Display screen
2. Electrodes
3. ON/OFF button
4. SET button
5. UP button
6. DOWN button
Setting and storing personal data
The scale can store personal data for up to 10 persons.
1. Press the ON/OFF button.
The personal key number ashes.
2. Press the UP/DOWN buttons to select a personal key (P0 to P9).
3. Press the SET button.
The gender symbols ash.
4. Press the UP/DOWN buttons to select user gender and condition:
• Male (
User instructions
)
• Female (
User instructions
)
• Male Athlete (
User instructions
)
• Female Athlete (
User instructions
)
5. Press the SET button.
The display shows the height.
6. Use the UP/DOWN buttons to specify user height (user height range may be between
80cm–220 cm or 2’ 7.5”–7’ 2.5”).
7. Press the SET button.
The display shows the age (user age range may be between 6 and 100 years).
8. Use the UP/DOWN button to specify user age.
9. Press the SET button.
The personal data is now set and stored.
Weighing
1. Press the ON/OFF button.
2. Use the UP/DOWN button to select your personal key number.
3. Step on the scale with bare feet and wait while the scale analyses your weight.
4. On completion, the following screens will be displayed alternately:

5
ENGLISH
1. Weight
2. Fat percentage
3. TBW percentage
(Total Body Water)
1. KCAL (daily caloric reference1)
2. MUS percentage (muscle)
3. BON (bone weight)
1To lose weight, you must consume fewer calories than this.
Result guidelines – female
Body fat ratio chart (%)
Age Normal and athlete mode
Underweight Healthy Overweight Obese
6–15 3.0–16.0 16.1–21.0 21.1–29.6 29.7–50.0
16–30 3.0–16.4 16.5–22.0 22.1–30.4 30.5–50.0
31–60 3.0–17.0 17.1–22.4 22.5–31.4 31.5–50.0
61–80 3.0–17.6 17.7–23.0 23.1–32.0 32.1–50.0
Water ratio chart and muscle ratio chart (%)
Age Normal and athlete mode
Low Healthy High Body Muscle
6–15 < 54.0 54.0–59.0 > 59.0
Normal: > 44
Athlete: > 46
16–30 < 53.0 53.0–58.0 > 58.0
31–60 < 52.0 52.0–57.0 > 57.0
61–80 < 51.0 51.0–56.0 > 56.0
Bone weight chart (kg)
Weight < 45 45–60 > 60
Ref. bone weight ≈ 3.0 ≈ 4.2 ≈ 6.5
KCAL Chart
Age Weight (kg) KCAL (normal mode) KCAL (athlete mode)
6–17 50 1265 1445
18–29 55 1298 1498
30–49 60 1302 1490

6
ENGLISH
Age Weight (kg) KCAL (normal mode) KCAL (athlete mode)
50–69 60 1242 1332
70–80 50 1125
Result guidelines – male
Body fat ratio chart (%)
Age Normal and athlete mode
Underweight Healthy Overweight Obese
6–15 3.0–13.0 13.1–17.4 17.5–25.6 25.7–50.0
16–30 3.0–13.6 13.7–18.0 18.1–26.4 26.5–50.0
31–60 3.0–14.0 14.1–18.6 18.7–27.0 27.1–50.0
61–80 3.0–14.4 14.5–19.0 19.1–28.0 28.1–50.0
Water ratio chart and muscle ratio chart (%)
Age Normal and athlete mode
Low Healthy High Body Muscle
6–15 < 57.0 57.0–62.0 > 62.0
Normal: > 46
Athlete: > 48
16–30 < 56.0 56.0–61.0 > 61.0
31–60 < 55.0 55.0–60.0 > 60.0
61–80 < 54.0 54.0–59.0 > 59.0
Bone weight chart (kg)
Weight < 60 60–75 > 75
Ref. bone weight ≈ 4.5 ≈ 6.0 ≈ 7.5
KCAL chart
Age Female Male
Weight (kg) KCAL Weight (kg) KCAL
6–17 50 1445 60 2030
18–29 55 1498 65 1810
30–49 65 1411 80 1784
50–69 65 1346 80 1720
Replace batteries
Open the battery cover (on the underside of the scale) by releasing the clip and lifting the
cover.

7
ENGLISH
Replace the batteries.
)Be sure the polarity of the batteries is set properly.
Always replace all the batteries at the same time.
Close the cover.
Troubleshooting
Carry out the following checks if the scale is not working properly:
• Make sure that the scale is not damaged.
• Make sure that all display settings are set properly.
LCD screen displays:
“LO” Install new batteries.
“Err” of “OL” Maximum weight has been exceeded.
“Err 2%” Indicates the error margin in the body fat percentage.
Maintenance:
Clean the scale with a lightly moistened cloth.
Do not use cleaning solvents or abrasives.
Warranty:
Any changes and/or modications to the product will void the warranty. We cannot accept any liability for damage caused by
incorrect use of this product.
Disclaimer:
Designs and specications are subject to change without notice. All logos, brands and product names are trademarks or registered
trademarks of their respective holders and are hereby recognized as such.
Disposal:
• This product is designated for separate collection at an appropriate collection point.
Do not dispose of this product with household waste.
• For more information, contact the retailer or the local authority responsible for waste management.
This product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all member
states of the European Union. It also complies to all applicable specications and regulations in the country of sales.
Formal documentation is available upon request. This includes, but is not limited to: Declaration of Conformity (and product
identity), Material Safety Data Sheet, product test report.
Please contact our customer service desk for support:
via website: http://www.nedis.com/en-us/contact/contact-form.htm
via telephone: +31 (0)73-5993965 (during oce hours)
NEDIS B.V., De Tweeling 28, 5215 MC ’s-Hertogenbosch, THE NETHERLANDS

8
DEUTSCH
Einleitung
Die digitale Personenwaage dient der akkuraten Messung des Körpergewichts und des
Körperfettes. Diese Waage funktioniert auf dem Prinzip der bioelektrischen Impedanzanalyse
(BIA). Durch die Messung des elektrischen Widerstandes und unter Einbeziehung von festen
Größen (Alter, Größe, Geschlecht, Aktivitätsgrad), können der Prozentsatz des Körperfettes,
Körperwassers und der Muskelanteil im Körper bestimmt werden.
Die Waage bietet Speicherplatz für zehn Personen.
Um genaue Messergebnisse zu erzielen, sollte der Nutzer folgende persönliche Parameter
eingeben:
- Geschlecht
- Größe
- Alter
• Bitte lesen Sie die Bedienungsanleitung, bevor Sie die Waage benutzen.
• Bewahren Sie diese Bedienungsanleitung für späteres Nachschlagen auf.
Die Waage wird mit 3x 1,5 V AAA-Batterien (nicht im Lieferumfang enthalten) betrieben.
Technische Spezikationen
Display: Digitales LCD-Display
Kapazität: 180 kg/396 lb
Abstufung: 0,1 kg/0,2 lb/¼ lb
Anzeigeauösung Körperfettanteil: 0,1%
Anzeigeauösung Körperwasseranteil: 0,1%
Altersbereich für Körperfettanteil: 6–100 Jahre
Körpergröße: 80–220 cm
Einheit für Körpergröße: cm/ft-in
Speicher: 10 Personen
Einheit für Gewicht: Kilogramm (kg)/Stone (st)/Pfund (lb)
Abmessungen: 32 x 32 x 2,5 mm
Gewicht: 2 kg
Sicherheitsvorkehrungen
• Stellen Sie sich nicht auf die Ecken der Waage, damit diese nicht umkippt.
• Benutzen Sie die Waage nicht, wenn Sie einen Herzschrittmacher oder ein anderes
internes elektrisches medizinisches Gerät tragen.
• Schwangere Frauen sollten die Waage nur zur Gewichtsmessung verwenden.
• Önen Sie die Waage im Fall von Fehlfunktionen nicht selbstständig. Das Gerät sollte
ausschließlich von qualizierten Technikern geönet werden.
• Setzen Sie die Waage keinen hohen Temperaturen oder hoher Feuchtigkeit aus.
• Entfernen Sie die Batterien, wenn Sie die Waage über einen längeren Zeitraum nicht
benutzen.

9
DEUTSCH
Installationsanleitungen
1. Abdeckung des Batteriefaches
2. Wahltaste für Gewichtseinheiten
Einlegen der Batterien
1. Önen Sie die Abdeckung des Batteriefaches (an der Unterseite der Waage), indem Sie
den Clip lösen und die Abdeckung abheben.
2. Legen Sie die Batterien ein.
)Beachten Sie dabei die Polarität der Batterien.
3. Schließen Sie die Abdeckung.
Wählen Sie den Wiegemodus
Schalten Sie die Waage ein (ON/OFF-Taste).
Wählen Sie mit der entsprechenden Taste (an der Unterseite der Waage) die gewünschte
Gewichtseinheit (kg/lb/st).
Aufstellen der Waage
Platzieren Sie die Waage auf einen festen, achen und ebenen Untergrund, um die
Messgenauigkeit zu gewährleisten.

10
DEUTSCH
Gebrauchsanweisung
User instructions
1. Display
2. Elektroden
3. Taste EIN/AUS
4. Taste SET
5. Taste HOCH
6. Taste RUNTER
Persönliche Daten eingeben und speichern
Die persönlichen Daten von bis zu zehn Personen können auf der Waage gespeichert werden.
1. Drücken Sie die Taste ON/OFF.
Die persönliche Kennzier blinkt auf.
2. Drücken Sie die Tasten UP/DOWN, um die persönliche Kennzier (P0 bis P9) zu wählen.
3. Drücken Sie die Taste SET.
Das Symbol für das Geschlecht blinkt auf.
4. Drücken Sie die Tasten UP/DOWN, um das Geschlecht des Benutzers und dessen
Verfassung zu wählen:
• Mann (
User instructions
)
• Frau (
User instructions
)
• Mann Athlet (
User instructions
)
• Frau Athlet (
User instructions
)
5. Drücken Sie die Taste SET.
Auf dem Display wird die Größe angezeigt.
6. Stellen Sie mit den Tasten UP/DOWN die Größe des Benutzers ein (Körpergröße kann im
Bereich von 80cm–220cm oder 2’7,5”–7’2,5”liegen).
7. Drücken Sie die Taste SET.
Auf dem Display wird das Alter angezeigt (Das Alter des Benutzers muss zwischen 6 und
100 Jahren liegen).
8. Geben Sie das Alter des Benutzers mit den Tasten UP/DOWN an.
9. Drücken Sie die Taste SET.
Die persönlichen Einstellungen werden gespeichert.
Wiegen
1. Drücken Sie die Taste ON/OFF.
2. Wählen Sie mit der Taste UP/DOWN Ihre persönliche Kennzier.
Indice
Lingue:
Altri manuali König Scala