KELCO ub25 Manuale utente

INSTALLATION
INTRODUCTION
INSTALLATION AND OPERATION INSTRUCTIONS FOR
THE UB25 IN LINE FLOW SWITCH
OPERATING ENVIRONMENT
The UB25 ow switch is a magnetically operated switch that will turn on or off in response to liquid ow. The body of the switch contains a piston that partly
obstructs the line of ow. To pass through the switch, the process liquid must push the piston back and ow over it and out through the outlet of the switch.
When owing liquid pushes the piston back, a magnet inside the piston actuates a reed switch in the electrical housing. The reed switch is used to provide
a set of closed (or open) electrical contacts that are either used directly as a switch, or to control an in built Triac or relay which in turn is used as the output
device.
The output of the switch can be used in control circuits to indicate ow, or to directly actuate small pump motors. The body of the UB25 ow switch contains
a second magnet that opposes the magnet in the piston. The repulsive force generated between the piston and the body magnets constantly pushes the
piston back to the off position, against the incoming ow. This unique magnet system negates the need for metal springs and provides the switch with
exceptional reliability.
The UB25 ow switch has a high pressure rated solid metal body, suitable for applications involving neutral liquids such as hot or cold water, or oils. The
UB25 ow switch contains a close tting piston, and should only be used in applications where the process uid is reasonably clean and free of entrained
or suspended material. This switch should not be used with uids containing large particulate matter, ferrous materials or brous matter. If the degree of
contamination of the process uid can’t be guaranteed, then suitable line ltration should be tted to the system. The standard UB25 ow switch is
constructed from solid brass. The piston and electrical housing are made from glass reinforced polypropylene.
The UB25 ow switches are weatherproof to IP67 and they are suitable for all outdoor exposed applications. The switch should be protected from exposure
to liquid temperatures in excess of 90°C. The UB25 series ow switch should not be used in applications where the line pressure exceeds 200 bars, in the
interest of safety, the switch has a burst pressure rating of >400 bars. Care should be taken not to expose this ow switch to excess back pressures such
as may be generated by a sudden reverse ow. In such applications, a dedicated non return valve should be tted to the system. The environmental
limitations and the main performance parameters of both models are set out in the table below.
The UB ow switch can be mounted in any orientation in the pipe work, including upside down. There is a direction of ow arrow on he electrical enclosure.
This directionality must be adhered to, as the switch will not operate against a reversed ow. Pipe work can be used to support the switch, or the switch
can be screwed directly into valve manifolds or pump ports. Use thread tape or sealant and do not use this ow switch as a non-return valve.
For increased sensitivity, UB25 inline ow switch is supplied with a non-magnetic piston retainer. The non-magnetic piston retainer is for use in vertically
mounted applications only. Please see maintenance details overleaf for information on installing the non-magnetic piston retainer.
OPERATING PARAMETERS
WARNING
Please read these installation and operating instructions fully and carefully before installing or servicing this Inline
Flow Switch. The UB25 Series in line ow switch is mains voltage device. Death or serious injury may result if this
switch is not correctly installed and operated. All electrical work must be performed by a fully qualied and licenced
electrician.
Parameters UB25 Standard UB25 With supplied non-magnetic piston retainer tted
Switching Point on a Slowly Rising Flow +/-15% 1.5 Litres per Minute 30 Litres Per Hour +-10%
Switching Point on a Slowly Falling Flow +/- 15% 1.2 Litres per Minute 30 Litres Per Hour +-10%
Minimum Gravity Head Required to Actuate the Switch 1.5 Metres 0.5 Metres
Maximum Recommended Continuous Flow (Water) 90 Litres per Minute 90 Litres per Minute
Maximum Recommended Operating Pressure,
Static or Dynamic
200 Bars (2900 PSI) 200 Bars (2900 PSI)
Minimum Burst Pressure 400 Bars (5800 PSI) 400 Bars (5800 PSI)
Maximum Liquid Temperature 90ºC 90ºC
Minimum Liquid Temperature -20ºC -20ºC
Ingress Protection Rating (Weatherproof Rating) IP67 IP67

ELECTRICAL
This ow switch can be supplied with one of four optional
electrical modules. The details of the various modules are
set out in the table below. The model of the switch and its
electrical module is indicated by a label xed to the inside of
the electrical enclosure of every switch.
MAINTENANCE
Please Note: All UB25 series ow switches use reed switches as the primary switching element. Reed switches are one of
the most reliable mechanical switching devices ever devised. They offer an operating life in excess of 100 million cycles,
however, care needs to be taken to ensure they are not electrically overloaded or if applied in questionable applications,
suitable protection should be added to the control circuit.
If the UB25 ow switch is correctly installed and if the process uid is compatible with the materials of construction of this
switch, then a very long maintenance free service life can be expected. Factors that may contribute to early failure of this
ow switch include excess temperature, excess pressure or electrical loads in excess of the circuit boards rating.
To service the piston or to install the non-magnetic piston retainer, Use a pair of long nosed pliers to remove the spring
Circlip located in the outlet port of the switch. Press the piston back with your nger, it should pop out along with its three
nned magnetic spider. Ensure there are no pieces of iron scale adhered to the piston or spider and that both parts are free
of damage. Reassemble the switch and test it to ensure the piston is a free and smooth t.
Most component of this switch are available in spare part kits.
ELECTRICAL DATA
WARNING
All electrical work associated with the UB25 Series in line
Flow Switch must be carried out by qualied electrical
personnel and all electrical work must conform to AS/NZ
(or equivalent) standards and to local wiring rules.
MODEL MODULE
TYPE
CONTACT
CONFIGURATION
SWITCHED
POWER
MAXIMUM
SWITCHED
VOLTAGE
MAXIMUM
SWITCHED
CURRENT
RESISTIVE AC
(RMS) MAXIMUM
INDUCTIVE LOADS
(POWER FACTOR
0.4)
TYPICAL APPLICATION
UB25-B Dry Reed
Switch
S.P.S.T N.O 40W 240V AC
200V DC
1 Amp Not Suitable PLC and General
Control Circuits
UB25-C Dry Reed
Switch
S.P.D.T.
Break Before Make
20W 140V AC
150V DC
1 Amp Not Suitable PLC Control and
Safety Showers
UB25-R Solid State
Relay
S.P.S.T. 750W 12 TO 240V
AC
Spike to 40 Amp 4A at 240V AC
AC Control Circuits and
AC Motor Control to a
Maximum of 1 HP, 0.75KW
KELCO Engineering Pty Ltd
ABN 20 002 834 844 Head office and factory: 9/9 Powells Road Brookvale NSW 2100 Australia. Postal Address: PO Box 7485 Warringah Mall Post
Shop Brookvale NSW 2100 Australia. Phone: +61 2 9905 6425 Fax: +61 2 9905 6420 Email: [email protected] Web: www.Kelco.com.au
PLEASE NOTE: Kelco Engineering Pty Ltd reserves the right to change the specication of this product without notice. Kelco Engineering Pty Ltd accepts no liability for personal injury or economic loss as
a consequence of the use of this product. All rights reserved copyright Kelco Engineering Pty Ltd © 2014 The Kelco UB25 is protected by a 12 month return to base warranty. Full details of our warranty
can be downloaded from: http://www.kelco.com.au/warranty
Altri manuali KELCO Interruttore

KELCO
KELCO D40 Manuale utente

KELCO
KELCO E30 Istruzioni per il montaggio

KELCO
KELCO F29 Manuale di installazione

KELCO
KELCO E30 Manuale di installazione

KELCO
KELCO D50 Manuale per l'uso e la cura

KELCO
KELCO F21 Series Schema elettrico

KELCO
KELCO E30 Mk2 Istruzioni per il montaggio

KELCO
KELCO E20 Series Manuale di istruzioni

KELCO
KELCO C15 Series Schema elettrico

KELCO
KELCO F29 Mk2 Istruzioni per il montaggio