KERN MCN-M Manuale utente

KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-
sohn.com
Tel: +49-[0]7433-
9933-0
Fax: +49-[0]7433-9933-
149
Internet: www.kern-
sohn.com
Service Manual
Medical Chair scale
KERN MCN-M
Type TMCN 200K-1M-A
Version 2.0
05/2022
GB
MCN-M-SH-e-2220

2 MCN-M-SH-e-2220
GB
KERN MCN-M
Version 1.0 –05/2022
Servicemanual
Table of contents
1Basic Information........................................................................................... 3
2Introduction.................................................................................................... 3
3Appliance overview ....................................................................................... 4
3.1 Feature overview........................................................................................................................ 7
3.2 Keyboard overview..................................................................................................................... 8
3.3 Installing the chair scales ........................................................................................................... 9
3.4 Levelling ................................................................................................................................... 10
3.5 Mains connection...................................................................................................................... 12
3.6 Safety cable.............................................................................................................................. 12
3.7 Rechargeable battery operation with an optional battery power pack ..................................... 13
3.8 Battery operation...................................................................................................................... 14
3.9 Insert batteries.......................................................................................................................... 15
3.10 Initial Commissioning................................................................................................................ 16
4Calibration and sealing information........................................................... 17
4.1 General introduction:................................................................................................................ 17
4.2 Verification notes:..................................................................................................................... 17
4.3 Position adjustment switch and seals:...................................................................................... 18
4.4 Verification validity period (current status in G)........................................................................ 18
5Service Menu................................................................................................ 19
5.1 Software identification .............................................................................................................. 20
5.2 Adjustment................................................................................................................................ 20
5.3 Adjustment procedure .............................................................................................................. 21
6Maintenance................................................................................................. 22
6.1 Service, maintenance............................................................................................................... 22
6.2 Error Codes .............................................................................................................................. 22
6.3 Check the Load cell.................................................................................................................. 23
6.4 Checking the different Voltages ............................................................................................... 23
6.5 Trouble Shooting ...................................................................................................................... 24
7Exchange of components ........................................................................... 25
7.1 Spare parts list.......................................................................................................................... 25
7.2 Opening the device................................................................................................................... 25
7.3 Exchange of components......................................................................................................... 26
7.4 Replacement of the main board ............................................................................................... 26
8Technical drawings...................................................................................... 27
8.1 Exploded view chair construction............................................................................................. 27
8.2 Exploded view indicator............................................................................................................ 29
8.3 TKMG/TKMH Wiring Diagram.................................................................................................. 31
8.4 TKMG/TKMH Functional Block Diagram.................................................................................. 32
8.5 TKMG/TKMH Schematic Diagram ........................................................................................... 33

MCN-M-SH-e-2220 3
1 Basic Information
The device must be repaired only by trained specialist staff or personnel with
professional formation (such as a repair-specialist accredited by law concerning
verification). The service manual is obligatory for repair work. After repair, original
conditions of the device must be restored. Only original spare parts should be used.
Instructions about conformity-evaluated scales:
Repair must be carried only at 100% compliance with the type approval. A violation
of this specification will result in a loss of the type approval! After successful repair
the balance will have to be reverified before it can be used again in a statutorily
regulated field.
The operation and configuration of each scale is described in the accompanying
manual of the scale. Any safety information in respect for verification are also
described in the accompanying manual
2 Introduction
This service manual covers the MCN chair scale series and is edited for the
authorized servicing personnel.
Note all rights are reserved. Copying any part of this manual is prohibited without our
permission.

4 MCN-M-SH-e-2220
3 Appliance overview
1. Seat pan
2. Bubble level
3. Display Unit
4. Manipulations
5. Parking brake
6. Adjustment switch
7. Terminal power supply unit
8. Connection cable "Display - Chair"
9. Battery compartment
10. KUP interface (Kern Universal Port)

MCN-M-SH-e-2220 5
Details:
Parking brake open
Parking brake closed
Footrest and adjustment foot
Accessory bag

6 MCN-M-SH-e-2220
Folding arm rests

MCN-M-SH-e-2220 7
3.1 Feature overview
•Large LCD, 6-digit H=25mm, VA=100x40mm, no backlight
•Stable, zero, battery level, gloss/net weight indications
•Weighing unit: kg only
•6 buttons operated
•Tare up to Max
•Pre-Tare function, with 4 memories
•BMI function
•Display Hold function
•Print function
•Application menu
•Setup menu
•Service menu
•Kern Communication Protocol (KCP)
•Kern Universal Port (KUP) interface, VGA-15 female connector
•Built-in WiFi interface
•Optional internal Memory / Real Time Clock module
•Optional external RS-232 interface through KUP
•Optional external USB device interface through KUP
•Optional external Bluetooth BLE interface through KUP
•Multi-Plug (EU/UK) Power adaptor, 6V 1A
•Optional Alkaline Batteries, 6xAA size
•Optional rechargeable battery pack, Li-ion 3.7V 3700mAH

8 MCN-M-SH-e-2220
3.2 Keyboard overview
Button
Designation
Function
ON/OFF button
Turn on/off
HOLD button
Hold function/Calculation of a stable weight value
In menu:
•Select menu items
For numeric entry:
•Lowering numeric value
BMI button
Calculation of the Body Mass Index
In menu:
•Return to weighing mode
PRINT button
Data transfer via interface
In menu:
•Select menu items
For numeric entry:
•Increase numerical value
Function key
Function quick key
Quick call-up of a function stored before
Zeroing key
Weighing scale will be reset to „0.0“
In menu:
•Confirm selection
For numeric entry:
•Change decimal digit
•Confirm entry
TARE key
Tare balance

MCN-M-SH-e-2220 9
3.3 Installing the chair scales
Place scales on an even surface.
Check if the air bubble of the level is within the prescribed circle.
If the air bubble of the bubble level is not in the required circle, level the
balance using the adjustment feet as specified.
Check levelling regularly.

10 MCN-M-SH-e-2220
3.4 Levelling
•Levelling is restricted to specialist staff possessing well acquainted
with the workings of weighing scales.
Place scales on an even surface.
Lock brakes
Turn the wheel (1) until the air bubble of the bubble level is in the black
circle
Turn the counter nuts (2) right to the top
Indice
Altri manuali KERN Scala

KERN
KERN PCB Series Manuale utente

KERN
KERN KERN MBB-M series Manuale utente

KERN
KERN EFB Manuale utente

KERN
KERN HFC Manuale utente

KERN
KERN FCE 3K1N Manuale utente

KERN
KERN WTB-BA-e-1214 Manuale utente

KERN
KERN ADB-A Series Manuale utente

KERN
KERN FCB Series Manuale utente

KERN
KERN EW - 300 - 2M Manuale utente

KERN
KERN HFT 3T0.5 Manuale utente

KERN
KERN EOA Series Manuale utente

KERN
KERN GAB-N Series Manuale utente

KERN
KERN 572 KB Manuale utente

KERN
KERN KERN 440...N Manuale utente

KERN
KERN RFE 6K3M Manuale utente

KERN
KERN UOB 600K200 Manuale utente

KERN
KERN PNJ Manuale utente

KERN
KERN ADJ Series Manuale utente

KERN
KERN EOB 10K-3B Manuale utente

KERN
KERN PCB 250-3 Manuale utente