KING CRAFT GEN154A Manuale utente

201002 GEN154A
2000 Surge Watts / 1200 Running Watts
PORTABLE GENERATOR
INSTRUCTION MANUAL
READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.
This manual provides important information on proper operation & maintenance. Every effort has been
made to ensure the accuracy of this manual. These instructions are not meant to cover every possible
condition and situation that may occur. We reserve the right to change this product at any time without
prior notice.
IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE,
DO NOT OPERATE THIS PRODUCT!
DO NOT RETURN THIS PRODUCT TO THE RETAILER - CONTACT CUSTOMER SERVICE.
If you experience a problem, have questions or need parts for this product, call Customer Service at
1-866-460-9436, Monday-Friday, 8 AM - 4 PM Central Time. A copy of the sales receipt is required.
FOR CONSUMER USE ONLY – NOT FOR PROFESSIONAL USE.
KEEP THIS MANUAL, SALES RECEIPT & APPLICABLE WARRANTY FOR FUTURE
REFERENCE.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 2
GEN154A 2000 Surge Watts / 1200 Running Watts Portable Generator
FEATURES:
• 4-Stroke OHV Engine
• Recoil Start
• 2.8 HP Unleaded Gasoline Engine / 3600 RPM
• 2-120 Volt 60 Hz / 10 AMP AC Outlets
• 1-12 Volt DC Outlet / 8 AMP
• 1.8 Gallon Fuel Tank
• Engine Run Time: 11 Hours @ 50% Load
• 2000 Surge Watts / 1200 Running Watts
• EPA Approved
• Insulation class F
• Power Factor 1.0

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 3
TABLE OF CONTENTS
PACKAGE CONTENTS
PACKAGE CONTENTS..........................................................................................................................................9
PREPARING THE GENERATOR FOR USE...................................................................................................................11
Using This Generator For The First Time.............................................................................................................11
Step 1 – Add Oil...........................................................................................................................................11
Step 2 – Add Unleaded Gasoline.................................................................................................................12
Step 3 – Ground The Generator...................................................................................................................12
Subsequent Use Of This Generator......................................................................................................................13
Step 1 – Verify Oil Level...............................................................................................................................13
Step 2 – Verify Unleaded Gas Level............................................................................................................13
Step 3 – Ground The Generator...................................................................................................................13
STARTING THE GENERATOR.......................................................................................................................................14
USING THE GENERATOR..............................................................................................................................................15
AC Usage.............................................................................................................................................................15
DC Usage.............................................................................................................................................................17
MAINTENANCE/CARE....................................................................................................................................................18
Cleaning The Generator.......................................................................................................................................18
Checking The Oil Level.........................................................................................................................................19
Changing/Adding Oil.............................................................................................................................................19
Air Filter Maintenance...........................................................................................................................................20
Spark Plug Maintenance.......................................................................................................................................20
Emptying The Fuel Tank.......................................................................................................................................20
THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 .
The emission-related warranty is valid for two (2) years. Keep the purchase receipt and mail in the product registration card for proof of purchase.
NB Corp limits emission-related warranty repairs to authorized service centers for owners located within 100 miles of an authorized service center.
For owners located more than 100 miles from an authorized service center, NB Corp will, in its sole discretion, either pay for shipping costs to and
from an authorized service center, provide for a service technician to come to the owner to make the warranty repair, or pay for the repair to be made
at a local non-authorized service center. The provisions of this paragraph apply only for the contiguous states, excluding the states with high-altitude
areas identified in 40 CFR part 1068, Appendix III.
To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1-866-460-9436 (email address
[email protected]) and you will be instructed on where to take the engine for warranty service. Take the generator and proof of purchase (your
receipt) to the repair facility recommended by the Customer Service Representative. The warranty does not extend to generators damaged or
affected by fuel contamination, accidents, neglect, misuse, unauthorized alterations, use in an application for which the product was not designed
and any other modifications or abuse.
1 YEAR LIMITED WARRANTY
Generators are warranted to be free from defects in materials and workmanship for a period of 1 year from date of original purchase. NB Corp. is
not liable for any indirect, incidental or consequential damages from the sale or use of this product. Any implied warranties are limited to 1 year as
stated, or as otherwise stated, in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential
damages. Some states do not allow limitation on the length of an implied warranty. NB Corp will repair or replace, at its discretion, any part that is
proven to be defective in materials or workmanship under normal use during the 1 year warranty period. Warranty repairs or replacements will be
made without charge for parts or labor. Parts replaced during warranty repairs will be considered as part of the original product and will have the
same warranty period as the original product. This warranty gives you specific legal rights, and you may have other rights that vary from state to
state.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 4
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS
What You Need to Know About Safety Instructions
Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and
situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and
equipment.
Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, may
result in property damage.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 5
Notice Regarding Emissions:
Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on
regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine
Modifications (EM).
Legal Requirements:
Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended
use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators
to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site.
IMPORTANT SAFETY INSTRUCTIONS
STOP!
Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this
generator, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.
Carbon Monoxide Gas: Generator exhaust contains carbon monoxide (CO2). This is a poison gas you cannot see or smell. If you can smell
the generator exhaust, you are breathing CO2. But even if you cannot smell the exhaust, you could be breathing CO2. • NEVER use a
generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas.
Using a fan or opening windows and doors does NOT supply enough fresh air.
• ONLY use a generator outside and far away from windows, doors, and vents. These openings can pull in generator exhaust. Even when you
use a generator correctly, CO2 may leak into the home. ALWAYS use a battery-powered or battery-backup CO2 alarm in the home.
• If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have
carbon monoxide poisoning.
Chemicals: According to the State of California, the exhaust from this generator contains chemicals known to cause cancer, birth
defects, or other reproductive harm.
Flammable Gasoline: This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or
even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline.
• Do not operate this generator near open flame.
• Do not smoke near this generator.
• Always operate this generator on a firm, level surface.
Gasoline is highly flammable and explosive. Handling fuel can result in serious injury or burns.
• Always shut down this generator before refueling. Refuel in a well-ventilated area. Keep heat, sparks and flame away while refueling and
away from the location where gasoline is stored. Never refuel indoors where gasoline fumes may reach flames and/or sparks.
• Allow this generator to cool for at least 2 minutes before removing the fuel tank cap. Loosen the cap slowly to relieve pressure in the fuel
tank. Avoid spilling fuel.
• Do not fill the fuel tank above the upper limit line. Gasoline may expand during operation. Do not fill to the top of the tank.
• Always check for spilled gasoline and immediately wipe it up before starting this generator.
• Empty the fuel tank before storing or transporting this generator.
• Always handle fuel outdoors.
• Before transporting, turn the fuel valve to the “OFF” position and disconnect the spark plug.
Environment Required: Protect the generator from direct sunlight. Do not select a location that is permanently subject to temperatures of
more than 40 °C and less than -15°C.
• If the generator is not operated at a temperature of between 5 - 40 °C and a height of 0 - 1000 m, the connected power consumption must be
reduced!
• Prevent this to ensure the longevity of the device and hazards!

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 6
Powerful Voltage: This generator produces powerful voltage, which can result in electrocution.
• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual).
• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical
system to this generator without a qualified electrician. Such connections must isolate generator power from utility power and comply with local
electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in serious
injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when utility power is restored.
• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs are available in-line with
some extension cords.
• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and operate
it with dry hands.
• Do not touch bare wires or outlets (receptacles).
• Do not allow children or non-qualified persons to operate this generator.
High Temperatures: This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees
Fahrenheit (65 Degrees Celsius).
• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces.
• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and
before storing indoors.
• Hot exhaust may ignite some materials. Keep flammable materials away from this generator.
• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure.
Usage: Misuse of this generator can damage it or shorten its life.
• Use this generator only for its intended purpose.
• Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved
in an emergency.
• Allow this generator to run for several minutes before connecting any electrical devices.
• Promptly turn off any malfunctioning devices and disconnect them.
• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator.
• Do not turn on electrical devices until after they are connected to this generator.
• Turn off all connected electrical devices before stopping this generator.
• Generators vibrate in normal use. During and after the use of the generator, inspect the generator as well as extension cords and power
supply cords connected to it for damage resulting from vibration.
• Have damaged items repaired or replaced as necessary.
• Do not use plugs or cords that show signs of damage such as broken or cracked insulation or damaged blades.
• For power outages, permanently installed stationary generators are better suited for providing backup power to the home.
• Even a properly connected portable generator can become overloaded.
• This may result in overheating or stressing the generator components, possibly leading to a generator failure.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 7

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 8
In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator.

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 9
PACKAGE CONTENTS
The following items are supplied with this Model GEN154A 2000 Surge Watts / 1200 Running Watts Portable Generator. Verify that all items are
included.
STOP!
If there are missing items, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service. DO NOT RETURN THIS
GENERATOR TO THE RETAILER.
Item List:
NEMA L14-30 plug for connecting 120 Volt electrical devices
Spark plug wrench

GEN154A 2000 Surge Watts/1200 Running Watts Portable Generator 10
GENERATOR COMPONENTS
Observe the locations and functions of the various components and controls of this generator.
1
2
11
10
9
5
6
7
8 3
4
1) Fuel Tank Cap
2) Control Panel
3) Grounding Terminal
4) Oil Access
5) Recoil Starter
6) Carburetor Choke Lever
7) Fuel Cock
8) Power On/Off
9) 120 V AC Outlets 10 Amp
10) 12 Volt DC Outlet 8 Amp
11) Pilot Lamp
12) AC Reset
13) DC Reset
12
13
Indice