Klein Tools 93LCLG Manuale utente

INSTRUCTION MANUAL
日本語 p. 21
한국어 pg. 11
93LCLG
Self-Leveling Green Cross Line
Laser Level with Red Plumb Spot
ENGLISH
• HORIZONTAL
AND VERTICAL
CROSS LINES
• PLUMB SPOT
IP54
93LCLG

2
ENGLISH
GENERAL SPECIFICATIONS
Klein Tools 93LCLG is a self-leveling laser alignment instrument that can be used to
deliver horizontal and/or vertical cross lines, and/or plumb spots directly above/below the
instrument, for alignment and layout applications.
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <80% non-condensing
• Operating Temp: 20°F to 115°F (-10°C to 45°C)
• Storage Temp: -5°F to 140°F (-20°C to 60°C)
• Lasers: • 515-530 nm (cross lines)
• 630-680 nm (plumb spots)
• ≤1mW each beam, Class II Laser Product
• Accuracy: ±3/32" per 33' (±2 mm per 10 m) Vertical & Horizontal Beams
±1/8" per 33' (±3 mm per 10 m) Plumb Up Spot
±5/32" per 33' (±4 mm per 10 m) Plumb Down Spot
• Battery Type: 3 x 1.5V AA Alkaline
• Dimensions: 5.3" x 5.0" x 2.8" (134 x 127 x 65 mm)
• Weight: 26 oz. (820 g) without batteries
• Calibration: Accurate for one year
• Standards: Conforms to: EN61326-1:2013, EN60825-1:2014.
Complies with 21 CFR 1040.10 and 1040.11 except for conformance with
IEC 60825-1 Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019.
• Ingress Protection: IP54 Dust & Water Resistant
• Electromagnetic Environment: IEC EN61326-1:2013. This equipment meets
requirements for use in basic and controlled electromagnetic environments like
residential properties, business premises, and light-industrial locations.
Specifications subject to change.

3
WARNINGS
To ensure safe operation and service of the instrument, follow these instructions. Failure
to observe these warnings can result in serious personal injury, re, or electrical shock.
Retain these instructions for future reference.
WARNING: LASER RADIATION. DO NOT STARE INTO BEAM. Class II Laser.
• Exposing eyes to laser radiation can result in severe and permanent eye injuries. NEVER look
directly into the laser beam emitted by this instrument.
• Do not use the instrument if it appears to be damaged.
• Do not modify the instrument in any way, as to do so could result in emission of hazardous laser
radiation than could result in severe eye injuries .
• Do not use optical equipment such as lenses, prisms, optical scopes, etc. to transmit, retransmit,
or view the laser beam as this could result in severe eye injuries.
• This product should not be used by untrained operators or operators who have not read and fully
understood the instructions.
• This product should not be used in any location that could result in somebody looking at or having
their eyes inadvertently irradiated by the laser beam as this could result in severe eye injuries.
• The instrument should be powered off following use to minimize the risks of inadvertently
exposure to hazardous laser radiation that could result in severe eye injuries.
• Do not remove warning labels from this instrument as this could result in serious personal injury
and increases the risk of exposure to hazardous laser irradiation.
• The instrument should be securely located in a tidy work environment prior to operation as
unexpected drops or movement of the instrument may result in damage to the instrument and
increases the risk of inadvertent exposure to laser radiation that could result in severe eye injuries.
• This instrument is IP54 dust & water resistant. Following any contact with water, thoroughly dry
the instrument with a dry, lint-free cloth.
• There are no user serviceable parts in this instrument.
Warning label
on side of
93LCLG

4
ENGLISH
7. Pendulum with Lasers
8. Horizontal Line Aperture
9. Vertical Line Aperture
10. Plumb Spot Aperture
1. Horizontal Line On/Off Button 11. Battery Compartment Door
2. Vertical Line On/Off Button 12. 1/4-20 Tripod Mount
3. Plumb Spot On/Off Button 13. 5/8-11 Survey Tripod Mount
4. Low Battery Indicator 14. Magnetic Mount Bracket
5. Excessive Tilt Indicator 15. Magnets
6.
Power/Pendulum Lock/Unlock Switch
16. Clamp-On Wall Adapter
FEATURE DETAILS
NOTE: There are no user-serviceable parts inside this instrument.
SYMBOLS ON INSTRUMENT
Vertical Laser Line
(Green) Low Battery Indicator Ingress Protection IP54 Rating –
Dust & Water Resistant
Horizontal Laser
Line (Green) Excessive Tilt Indicator Hazardous laser radiation
Plumb Spot Laser
(Red) Battery Polarity Warning or Caution
WEEE: Electronics
disposal
Conformité Européenne:
Conforms with European
Economic Area directives
UKCA: UK Conformity
Assessment
Laser Class 2 DO NOT stare into beam or view
directly with optical instruments
Read instructions
16
2
6
7
8
5
10
31
9
4
TOP
11
SIDE
BACK
1213
BOTTOM
14
15
11

5
OPERATING INSTRUCTIONS
TURNING LASER BEAMS ON/OFF
Push the ON/OFF buttons for the horizontal line
1
, vertical line
2
, and plumb
spot
3
to turn ON and OFF their respective laser lines. These buttons are only active once
the Pendulum Lock/Unlock Slider Switch
6
has been set to the Unlocked position. If
the Pendulum Slider Switch is moved from the Unlocked to the Locked position while the
laser beams are active, they will be turned OFF. The different laser lines can be operated
independently or simultaneously.
NOTE: The plumb spot application projects laser beams both in upward and downward
directions. The downward beam may be used to locate a specific point on a floor layout
while the upward beam projects that same point to a ceiling.
PENDULUM SLIDER SWITCH & SELF-LEVELING
The laser assemblies are mounted on a pendulum so that the instrument can self-level. The
Pendulum Slider Switch
6
must be in the unlocked position for the instrument to self-
level. If the instrument is tilted by >4°from the horizontal plane, the pendulum will not be
capable of self-leveling; the active laser beams will flash and the Excessive Tilt Indicator
5
will blink to indicate that the instrument is not level and cannot self-level. The instrument
must be repositioned on a more level geometry for the self-Leveling pendulum to function
appropriately.
NOTE: If the instrument indicates that it is not level
(via flashing beams and/or a blinking Excessive Tilt
indicator
5
),
then it should not be used for laying
out level or plumb lines.
NOTE: Following use, the active laser beams must be
turned OFF and the Pendulum Slider Switch must be
placed in the Locked position prior to storage.
InstrumentInstrument TiltedTilted ExcessivelyExcessively
Horizontal Laser LineHorizontal Laser Line Vertical Laser LineVertical Laser Line Plumb Laser LinePlumb Laser Line

6
ENGLISH
OPERATING INSTRUCTIONS
MAGNETIC MOUNTING BRACKET 14
The instrument is attached to a magnetic mounting bracket. The bracket may be
magnetically attached to any magnetic structure such as steel studs, ducts, structural
beams, and steel doors. The bracket also features a key-hole for mounting the instrument
using a screw or nail to non-magnetic structures. Once mounted to a structure via the
mounting bracket the instrument can be rotated on the bracket through 360°to direct the
laser beams.
CLAMP-ON WALL ADAPTER 16
The clamp-on wall adapter may be clamped to a structural beam, or wall bracket for
suspended ceiling installations, to present a steel surface onto which the instrument's
magnetic mounting bracket may be attached. Once magnetically attached the instrument
may be positioned to deliver the laser line at the required location. The clamp-on adapter
also features a key-hole for mounting the instrument using a screw or nail.
Mounted via keyholeMounted via keyholeMounted via magnetMounted via magnet
Adapter mounted on ceiling bracketAdapter mounted on ceiling bracket Adapter mounted via keyholeAdapter mounted via keyhole

7
VERIFYING ACCURACY OF LASER LINES
Horizontal Beam Left/Right Tilt
Secure instrument via its mounting bracket at a distance xfrom a vertical wall structure as shown.
Rotate the instrument on the bracket to the left so that the right side of the beam is projected on the
wall directly across from the instrument, mark the vertical location on the wall. Rotate the instrument
to the right and repeat marking the vertical location of the left side of the beam. At ~33' (10 m) the
vertical distance dbetween the left-side and right-side markings should be ≤ 5/32" (4 mm). For
example, if xis set to 15' (4.6 m), the vertical distance dshould be ≤3/32" (2 mm).
WALL
Vertical distance
between markings
Right
Left
d
L
L
x
R
R

8
ENGLISH
VERIFYING ACCURACY OF LASER LINES
Vertical Beam Tilt
Position the instrument on the floor and project a vertical beam along a line xof about 6'
(1.9 m). Mark point a on the ceiling. Position the instrument on the other side of the line
and repeat marking point bon the ceiling. The distance dshould be ≤5/32" (4 mm) for a
33' (10 m) ceiling or ≤3/32" (2 mm) for a 15' (4.6 m) ceiling.
x
d
a
b
WALL
WALL
Horizontal Beam Out-of-Plane Tilt
Position the instrument parallel to a wall and project a beam along the wall, from left to right as
shown. Mark two locations (a, b) along the beam separated by distance x. Position the laser at
the other side of the wall and project the beam back through mark b, from right to left as shown,
and mark position c. If x is 30' (9.1 m), then the vertical distance dshould be ≤ 5/32" (4 mm). For
example, if xis set to 15' (4.6 m), then the vertical distance dshould be ≤ 3/32" (2 mm).
d
a
b
c
x
WALL
WALL

9
VERIFYING ACCURACY OF LASER LINES
Plumb Spot
Position instrument on the floor and project a spot with the plumb spot laser to the ceiling.
Rotate the laser by 180°and project the exact same spot to the ceiling. The distance d
should be ≤1/4" (6mm) for a 33' (10m) ceiling or ≤1/8" (3mm) for a 15' (4.6m) ceiling.
CEILING
d
180°

10
ENGLISH
BASED ON: 1390349 Rev 12/21 B
CLEANING
Be sure laser level is turned off and wipe with a clean, dry lint-free cloth.
Do not use
abrasive cleaners or solvents.
STORAGE
Remove the batteries when the instrument is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications section, allow the
laser level to return to normal operating conditions before using.
FCC AND IC COMPLIANCE
See this product’s page at www.kleintools.com for FCC compliance information.
Canada ICES-003 (B) / NMB-003 (B)
WARRANTY
www.kleintools.com/warranty
DISPOSAL /RECYCLE
Do not place equipment and its accessories in the trash. Items must be
properly disposed of in accordance with local regulations. Please see
www.epa.gov/recycle for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street Lincolnshire, IL 60069 1-800-553-4676
[email protected] www.kleintools.com
MAINTENANCE
BATTERY REPLACEMENT
When the Low Battery indicator
4
is illuminated red,
the batteries must be replaced.
1. Open the battery compartment door
11
.
2. Remove and recycle three spent AA batteries.
3. Install new batteries (note proper polarity).
4. Close battery compartment,
ensuring that it is securely shut.
한국어
Altri manuali per 93LCLG
1
Indice
Lingue:
Altri manuali Klein Tools Livello laser

Klein Tools
Klein Tools 93LCL Manuale utente

Klein Tools
Klein Tools 93PLL Manuale utente

Klein Tools
Klein Tools 93LCLS Manuale utente

Klein Tools
Klein Tools 93LCL Manuale utente

Klein Tools
Klein Tools 93LCLG Manuale utente

Klein Tools
Klein Tools LBL100 Manuale utente

Klein Tools
Klein Tools 93PLL Manuale utente

Klein Tools
Klein Tools 93LCLGR Manuale utente