KNOVA KN 8059 Manuale utente

KNOVA
Digital clamp multimeter
Multímetro digital de gancho
600V
KN 8059

Safety Information 1
Safety Symbols 1
Warning 1
Maintenance 2
Introduction 3
Description 3
Panel Description 5
Operation 6
Accuracy Specication 10
General Specications 13
Auto power off 13
Replace battery 14
Accessory 14
TABLE OF CONTENTS

KNOVA
SAFETY INFORMATION
This meter is designed and manufactured according to the safety
requirements set out by the IEC61010-1 standards for electronic test
instruments and the hand-hold digital multimeters. Its design and
manufacture is strictly based on the provisions in the CAT III 600V of
IEC61010-1 and the Stipulation of 2-Pollution Grade.
Safety Symbols
Risk of danger. Important information. See manual.
Hazardous voltage.
Application around and removal from Hazardous Live conductors is
permitted.
Double insulated (Protection class II)
Earth ground
• To avoid possible electric shock, personal injury, or death, read
the following before using the Meter:
• Use the test leads supplied to ensure operation safety. If required,
they must be replaced with test leads of the same model or class.
• Inspect the test leads before use. Do not use them if insulation is dam
aged or metal is exposed. Check the test leads for continuity. Replace
damaged test leads before using. Do not use the Meter if it appears
damaged.
• Do not touch the metal tips of the test leads when the meter is con
nected to the circuit to be measured.
1
!WARNING

• When Voltage > 60 V dc or ac peak .keep your ngers behind the
nger guards.
• Verify the Meter’s operation by measuring a known voltage before and
after using it. Do not use the Meter if it operates abnormally.
Select the highest range if the value scale to be measured in the
manual range is unknown.
• Do not take voltage measurement if the value between the terminals
and earth ground exceeds 600V.
• Disconnect the test leads from the circuit under test before turning the
rotary selector to change functions.
• Disconnect circuit power and discharge all high voltage capacitors
before testing resistance, continuity, diodes, or capacitor.
• Do not store or use the meter in areas exposed to direct sunlight, at
high temperature or with high relative humidity.
• Do not touch live circuit or exposed metal
MAINTENANCE
• Before opening the rear of the meter, disconnect test leads from all
sources of electric current.
• Use damp cloth and mild detergent to clean the meter; do not use
abrasives or solvents.
• Whenever it is likely that safety protection has been impaired, make the
Meter
• Inoperative and secure it against any unintended operation.
• Have the Meter serviced only by qualied service personnel
2

KNOVA
INTRODUCTION
This meter 3 3/4 digits with steady operations, fashionable structure
and highly reliable measuring instrument. The Meter uses large scale of
integrated circuit with double integrated A/D converter as its core and has
full range overload protection.
The meter can perform measurements of AC current, AC/DC voltage,
resistance, capacitance as well as continuity and diode test.
DESCRIPTION
1. Transformer Jaws:
Designed to pick up the AC current owing through the conductor.
2. Hand Guards:
To protect user’s hand from touching the dangerous area.
3. Rotary Switch
Select proper Range and function.
4. HOLD button
Pressing the “hold” button the meter stops updating the LCD panel,
LCD display “ ”,press the button again and the meter exits hold
mode.
5. RAN auto/manual Range button
In Voltage resistance measurement mode, the default mode is auto
range, press RAN button switch to turn to manual range; while in
manual range mode changes the full-scale range, press this button
more than 2 seconds ,the meter will switch to auto range.
H
3

6. LCD Screen
Max Display 3999
7. INPUT Terminals
Input positive terminals for all measurements except current measure
ments, connected with red test leads.
8. COM Terminals
Input common terminals for all measurements except current mea
surements, connected with black test leads.
9. Hz% Frequency and duty Switch Button
Under AC voltage measurement, press Hz% button to select a function
from voltage, frequency to duty.
10. SEL: Function selecting button
In voltage mode, press the SEL button to toggle from DCV to ACV;
in mode, it is used to select a function from resistance, capaci
tance, diode to continuity.
11. Back light
Press the “ ” button more than two seconds to turn on the back light,
press again to turn it off.
12. Trigger
Press the lever to open the transformer jaws. When the pressure
on the lever is released, the jaws will close.
13. Transformer Jaws Lighting Bulb
Switch rotary switch to current position, then turn on lighting Bulb and
back light.
4

KNOVA
1
2
3
4
5
6
8
9
10
11
12
13
7
PANEL DESCRIPTION
5

~
!
!
WARNING
WARNING
MEASUREMENT OPERATION
DC Voltage Measurement
1. Plug the black test lead into the COM terminals and the red test lead
into the INPUT terminals
2. Set the rotary switch to V , press SEL button switch to DC voltage,
connect the test leads to the object being measured.
3. The measured value shows on the display.
• Select the highest range if the value scale to be measured
in the manual range is unknown
•To avoid harms to you or damages to the Meter from electric shock
AC Voltage Measurement
1. Plug the black test lead into the COM terminals and the red test lead
into the INPUT terminals
2. Set the rotary switch to V , press SEL button switch to AC voltage,
connect the test leads to the object being measured.
3. The measured value shows on the display
•To avoid harms to you or damages to the Meter from
electric shock
~
6

KNOVA
AC Current Measurement
1. Set the rotary switch to proper current range.
2. Press the lever to open the transformer jaws, center the conductor
within the transformer jaw. Please only measure one conductor at a
time.
3. The measured value shows on the display.
•Select the highest range if the value scale to be measured is
unknown, then adjust the rotary switch until get satisfactory
resolution.
•To avoid harms to you or damages to the Meter when measuring
exposed conductor.
Measuring Resistance
1. Plug the black test lead into the COM terminals and the red test lead
into the INPUT terminals
2. Set the rotary switch to press SEL button switch to Ω, Connect
the test leads to the object being measured.
3. The measured value shows on the display
•At the manual range mode, when only “OL” is shown on the
LCD, it means the measurement has exceeded the range. A higher
range should be selected.
•When measuring in-circuit resistance, make sure that the power of
the circuit under test has been turned off and that all capacitors
have been fully discharged.
WARNING
WARNING
!
!
7

Measuring Diode
1. Plug the black test lead into the COM terminals and the red test lead
into the INPUT terminals
2. Set the rotary switch to , press SEL button switch to , Connect
the test leads to the object being measured (Connect the red test lead to
the anode and the black test lead to the cathode of the diode).
3. The Measured value shows on the display
Testing for Continuity
1. Plug the black test lead into the COM terminals and the red test lead
into the INPUT terminals
2. Set the rotary switch to , press SEL button switch to , Connect
the test leads to the object being measured.
3. The buzzer sounds if the resistance of a circuit under test is less than
60
The buzzer may or may not sounds if the resistance of a circuit
under test is between 60 Wto 120 W, the buzzer does not sound if
the resistance of a circuit under test is higher than 120W.
Measuring Capacitance
1. Plug the black test lead into the COM terminals and the red test lead
into the INPUT terminals
2. Set the rotary switch to , press SEL button switch to , connect
the test leads to the object being measured.
3. The Measured value shows on the display
8
Indice
Lingue:
Altri manuali KNOVA Multimetro
Manuali Multimetro popolari di altre marche

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuale utente

PeakTech
PeakTech 4000 Manuale per l'uso e la cura

YOKOGAWA
YOKOGAWA 90050B Manuale utente

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuale utente

Fluke
Fluke 8846A Manuale operativo e di manutenzione

Tempo Communications
Tempo Communications MM200 Manuale utente