BEFORE YOU BEGIN
!
!
!
!
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operation and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information -
.
This product complies with GB 4706.1-2005, GB4706.23-
2007 and GB 4706.27-2008.
please leave instructions for the
consumer
!
!
!
!
,
-
GB 4706.1-2005 GB4706.23-2007 GB
4706.27-2008
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
A licensed
electrician should make all electrical connections.
Connect only to
a circuit protected by a typical two-pole circuit breaker.
Disconnect
power before servicing.
!
!
!
!
!
!
!
!
!
!
Tape measure
Level
Screw driver
Connection wire
Wire cutter
Insulation tape
Bushing
Percussion Drill
Pen Knife
Wrench
!
!
!
!
!
!
!
!
!
!
RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS
Kohler reserves the right to change marked dimensions without prior notice.
Unit: mm
:
Reference Value
ROUGHING-IN
Junction Box Cover
49
179
28
10
217
Ventilation Outlet
410
429
300
450
Hot Air Outlet
242
270
290
©
©
Copyright Kohler China Investment Co., Ltd. 2018
2018
1290505-T01-C

-2-
SPECIFICATIONS
Model K-77315T-MZ/K-77315T-X-MZ/
K-77283T-MZ
K-77315T-MZ/K-77315T-X-MZ/
K-77283T-MZ
Voltage/Frequency /
220V~/50Hz 220V~/50Hz
Rated Input Power 2650W 2650W
Heater Power
Fan Power
Dry Clothing Power
Ventilation Power
2630W 2630W
30W 30W
2650W(Hot)/55W(Cool) 2650W( )/55W( )
25W 25W
Air-care Power 30W 30W
Lighting Power
Ventilation Volume
Ventilation Noise
Ingress Protection
12W 12W
2.7m /min
32.7m /min
3
39dB 39dB
IPX2 (Bathroom Heater) IPX2 ( )
IPX4 (Remote Control) IPX4 ( )
SIMPLIFIED DIAGRAM OF THE UNIT
Expansion Pipe
M6 Screw Rod
M6
M6 Butterfly Nut
M6 Hanger
BTP4*8 Self Tapping Screw
BTP4*8
Ventilation Outlet Assy.
Air Exhaust Pipe
Clamp
Air Outlet Window
Keel
M6 Nut
M6
6
6
Spring Washer 6Washer
6
BTP4*8 Triangular
Self Tapping Screw
BTP4*8
Note: Plaster or other ceiling opening dimension: 450 X 290 (mm)
450 X 290 (mm)
+5
0
+5
0
+5
0
+5
0
WIRING DIAGRAM
K-77315T-MZ
LED POWER
LED
HEATER 2 2
HEATER 1 1
THERMOSTAT
THERMAL FUSE
OVER CURRENT FUSE
VENT MOTOR
HOT MOTOR
CAPACITOR
CAPACITOR
ALL-POLE SWITCH (OPTIONAL)
220V
50Hz
CN4
CN7
CN8
CN5
CN6
CN2
CN3
CN9
CN13
CN1
CN11
CN12
CN10
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
AIR-CARE MODULE
STEPPER MOTOR
INDICATOR LIGHT
MODULE
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 20A
250V 20A
YELLOW/GREEN
/
RED
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
BLACK
BLACK
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
BROWN
BROWN
GRAY
PINK
PINK
YELLOW
YELLOW
ORANGE
ORANGE
MAIN CONTROL CIRCUIT BOARD
1290505-T01-C

-3-
+
+
+
+
+
+
There's no risk of damage to the insulation of power cord.
Copper cord must be inserted into the pillar terminal hole, and make
sure all the cords under the terminal are inserted into the pillar
terminal completely.
Suggest using a power cord which with specification 60227 IEC 53
Model's powercord Specified in GB/T 5023.5 and with cross section
of 3X1.5mm .
,
GB/T 5023.5 60227 IEC 53 ,
3X1.5mm
2
2
Terminal
Conductor
Insulation 8
(Unit: mm)
(: )
WARNING
Make sure the power cord installed firmly,
otherwise it may catch fire.
Conductor
Earth
Power Cord
8
8
13 10
LED POWER
LED
LED POWER
LED
HEATER 2 2
HEATER 2 2
HEATER 1 1
HEATER 1 1
THERMOSTAT
THERMOSTAT
THERMAL FUSE
THERMAL FUSE
OVER CURRENT FUSE
OVER CURRENT FUSE
VENT MOTOR
VENT MOTOR
HOT MOTOR
HOT MOTOR
CAPACITOR
CAPACITOR
CAPACITOR
CAPACITOR
ALL-POLE SWITCH (OPTIONAL)
ALL-POLE SWITCH (OPTIONAL)
220V
50Hz
220V
50Hz
CN4
CN4
CN7
CN7
CN8
CN8
CN5
CN5
CN6
CN6
CN2
CN2
CN3
CN3
CN9
CN9
CN13
CN1
CN11
CN12
CN12
CN10
CN10
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
AIR-CARE MODULE
CLOUD
COMMUNICATION
ASSEMBLY
STEPPER MOTOR
STEPPER MOTOR
INDICATOR LIGHT
MODULE
INDICATOR LIGHT
MODULE
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 20A
250V 20A
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 20A
250V 20A
YELLOW/GREEN
/
YELLOW/GREEN
/
RED
RED
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
BROWN
BROWN
BROWN
BROWN
GRAY
GRAY
PINK
PINK
PINK
YELLOW
YELLOW
YELLOW
ORANGE
ORANGE
ORANGE
MAIN CONTROL CIRCUIT BOARD
MAIN CONTROL CIRCUIT BOARD
K-77315T-X-MZ
K-77283T-MZ
1290505-T01-C

-4-
PREPARATIONS BEFORE INSTALLATION
A. Preparation before the installation A.
1. Open the hole of outlet window
Make sure that the outlet window s position (it should be
lower than the outlet of the bathroom heater to prevent the
water come back to the bathroom heater from the outlet
window), and open a round hole on the wall.
2. Outlet window installation
Fix the air exhaust pipe to the outlet window on the wall
with the clamp as the preparation of bathroom heater
installation. Seal the pipe and the outlet window with
foaming agent.
1.
(
)
2.
Ceiling
Air Exhaust Pipe
Wall
Inside Outside
Outlet Window
The situation of outlet window on the
wall outside.
The situation of outlet window on the
wall inside.
Outlet Window
Outlet Window
Hole on the Wall Hole on the Wall
80mm
80mm
115mm
115mm
B. Take out the bathroom from package. B.
Bathromm Heater
1290505-T01-C

1285547
80 Air Outlet Window
80
1285548
80 Air Exhaust Pipe
80
1285549
Clamp
2
1285552
Fixed Column Assy.
M6 Expansion Head
M6
10 Expansion Pipe
10
M6 Screw Rod
M6
1285553
Lock Assy. /
M6 Butterfly Nut
M6
6 Washer
6
6Spring Washer
6
M6 Nut
M6
Note: Initial Length:275mm
Stretch Length: 1300mm
275mm
1300mm
270mm
C. Packing List C.
-5-
1285554
Decorated Plate X2
X2
1285555
Remote Control
(Only K-77315T-MZ/
K-77315T-X-MZ)
( K-77315T-MZ/
K-77315T-X-MZ)
1285542
Install Template
1285550
Ventilation Outlet Assy.
1285551
Heater Accessories Package
Hanger
Triangular
Self-tapping Screw
BTP4*8
BTP4 8 Triangular
Self Tapping Screw
BTP4 8
1285556
Remote Control Base Assy.
Cover
*2
M4*25Screw
*2
Base
6 Plastic
Expansion Pipe
6*2
1288668
Remote Control
(Only )
()
K-77283T-MZ
K-77283T-MZ
1290505-T01-C

-6-
INSTALLATION
Caution before installation:
!
!
!
!
!
!
The installed product must be 200mm or above away from
curtains or other combustible materials.
The distance between the ceiling where the product is
mounted and the roof shall be 200mm or above.
Ensure that the gap between the product edge and the
wall is 300mm or above.
The power cord to the product shall have enough length
for the installation.
The distance between the product and the air outlet
window shall be 1000mm or lower.
Cut the screw rod(M6) to suit the distance between the
ceiling and the roof.
!
!
!
!
!
!
200mm
200mm
300mm
1000mm
(M6)
Air Exhaust Pipe
Wall Lower than 1000mm
1000
300mm above
300 300mm above
300
Air Outlet Window
Bathroom Heater
1. Connecting the power cord
(1) Pass the power cord through the ceiling.
1.
(1)
Power cord
Decorated Plate
1290505-T01-C

2. Fix the power cord to the bathroom heater
(1) Remove the screw on the wiring cover plate.
(2) Open the wiring cover plate.
(3) Lift the terminal protection cover.
(4) Loosen the screw fixing the power cord clip.
(5) Loosen the screw on the wiring terminal, insert the
power cord (not supplied) connected to the indoor fixed
line into the wiring terminal, tighten the wring terminal
screw.
(6) Fix the power cord with power cord clips. (The power
cord clip must pin the insulation sheath of power cord.)
(7) Use the screw removed in step (3) to fix the wiring
cover plate again.
2.
(1)
(2)
(3)
(4)
(5) (
)
(6) (
)
(7) (3)
Power cord
LN
Wiring Terminal
3. Installing the Main Body Method 1 integrated ceiling.
integrated ceiling should be 300*300, 300*450, 300*600
(1) Disassembly the decorated plate around the position of
the product installation.
3.
300*300 300*450 300*600
(1)
()
300mm*300mm integrated ceiling
300mm*300mm
Disassembly 6 pieces
6Disassembly 6 pieces
6
300mm*450mm integrated ceiling
300mm*450mm
300mm*600mm integrated ceiling
300mm*600mm
Disassembly 3 pieces
3
-7-
(2) Use the install template as the diagram to insert it into
the ceiling to mark the position of the drill.
(2) 90
300mm*300mm integrated ceiling
300mm*300mm
Bending line
Install Template
Install Template
Install Template
Install Template
Install Template
Cement Board
Cement Board
Ceiling
Drill Position
600
465
200
300
Bottom view
1290505-T01-C

-8-
(3) Fix the suspender on the right position of the cement
board, use the install template to adjust the M6 nut on
the suspender.
(4) Fix the suspension bracket on the suspender by 8
BTP4*8 screw.
(3)
M6
(4) 8 BTP4*8
M6 Butterfly Nut
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
M6 Nut
M6
BTP4*8 Triangular Self Tapping Screw
BTP4*8 (8 )
Suspender
Cement Board
Ceiling Surface Install template datum line
(5) Fix the product on the M6 suspender by the suspension
bracket.
(5) M6
M6 Butterfly Nut
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
M6 Screw Rod
M6
1290505-T01-C

-9-
(6) Install the air exhaust pipe
1) Fix the air exhaust pipe on the ventilation outlet assy.
by the clamp. The pipeline connected to outside of
the room must be slanted to prevent rain or
condensed water from flowing backwards.
(6)
1)
Outdoors
Indoors
Slant Taper 1
100
1
50
~
()
BTP4*8 Triangular
Self Tapping Screw
BTP4*8 (1 )
80 Ventilation Outlet Assy.
80
Ventilation Outlet Assy.
Clamp
Air Exhaust Pipe
()
80mm
(7) Install the decorated plate and adjust the nut on the
suspender to keep them on the same horizontal surface.
Lock the nut after the adjustment.
(8) Install the remaining decorated plate (finish the product
installation)
(7) M6 M6
(8) ( )
Decorated Plate
Base
300mm*300mm integrated ceiling
300mm*300mm
1290505-T01-C
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali Kohler Stufa

Kohler
Kohler S300 Manuale utente

Kohler
Kohler S600GP Manuale utente

Kohler
Kohler K-77316T-MZ Manuale utente

Kohler
Kohler S300G Manuale utente

Kohler
Kohler PA-253213 Manuale utente

Kohler
Kohler Veil S600P Manuale utente

Kohler
Kohler S300 Manuale utente

Kohler
Kohler S300 Manuale utente

Kohler
Kohler K-77316T-C-MZ Manuale utente

Kohler
Kohler K-21465T-G-0 Manuale utente
Manuali Stufa popolari di altre marche

Empire Heating Systems
Empire Heating Systems WCC65 Manuale utente

Wetekom
Wetekom 92 86 43 Manuale utente

Desa
Desa SPC170-F Manuale utente

Watlow
Watlow Watrod Electric Tubular Heaters Manuale utente

Haverland
Haverland ECO-DRY GPS Series Manuale elenco delle parti

Stelpro
Stelpro ASILVC2060 Series Manuale utente