BEFORE YOU BEGIN
!
!
!
!
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operation and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information -
.
This product complies with GB 4706.1-2005, GB4706.23-
2007, GB 4706.27-2008, GB7000.1, GB7000.202 and
GB/T17743.
please leave instructions for the
consumer
!
!
!
!
,
-
GB 4706.1-2005 GB4706.23-2007 GB
4706.27-2008 GB7000.1 GB7000.202 GB/T17743
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
A licensed
electrician should make all electrical connections.
Connect only to
a circuit protected by a typical two-pole circuit breaker.
Disconnect
power before servicing.
!
!
!
!
!
!
!
!
!
!
Tape measure
Level
Screw driver
Connection wire
Wire cutter
Insulation tape
Bushing
Percussion Drill
Pen Knife
Wrench
!
!
!
!
!
!
!
!
!
!
RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS
Kohler reserves the right to change marked dimensions without prior notice.
Unit: mm
:
Reference Value
ROUGHING-IN
Junction Box Cover
Ventilation Outlet
Hot Air Outlet
Kohler Logo
©
©
Copyright Kohler China Investment Co., Ltd. 2019
2019
564
589
600
300 289 268
167
148
Inlet(where filter mat is installed)
()
1367356-T01-A

-2-
SPECIFICATIONS
Model K-21463T-0/K-21463T-X-0/
K-21465T-0
K-21463T-0/K-21463T-X-0/
K-21465T-0
Voltage/Frequency /
220V~/50Hz 220V~/50Hz
Rated Input Power 2750W 2750W
Heater Power
Fan Power
Dry Clothing Power
Ventilation Power
2731W 2731W
30W 30W
2600W(Hot)/60W(Cool) 2600W( )/60W( )
33W 33W
Air-care Power 31W( )K-21463T-0/K-21463T-X-0 Only 31W( K-21463T-0/K-21463T-X-0)
Lighting Power
Ventilation Volume
Ventilation Noise
Ingress Protection
19W 2 (108pcx 0.2W) 19W 2 (108 0.2W)
m /min
3
3.3 3.3m /min
3
43dB 43dB
IPX2 (Bathroom Heater) IPX2 ( )
IPX4 (Remote Control)
IP20 (LED)
IPX4 ( )
IP20 (LED )
SIMPLIFIED DIAGRAM OF THE UNIT
WIRING DIAGRAM
K-21463T-0
Hanger
BTP4*8 Tri-Self Tapping Screw
BTP4*8
BTP4*8 Tri-Self
Tapping Screw
BTP4*8
Expansion Pipe
M6 Screw Rod
M6
M6 Butterfly Nut
M6
Keel
M6 Screw Nut
M6
6 Cushion
6
6 Washer
6
Air Outlet Window
Clamp
Air Exhaust Pipe
Ventilation Outlet Assy.
MAIN CONTROL CIRCUIT BOARD
ALL-POLE SWITCH (OPTIONAL)
220V
50Hz
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 20A
250V 20A
HOT MOTOR
VENT MOTOR
YELLOW/GREEN
/
HEATER 1 1
HEATER 2 2
THERMOSTAT
THERMAL FUSE
OVER CURRENT FUSE
CAPACITOR
CAPACITOR
CN4
P5
P4
P3
P2
P1
CN7
CN8
CN5
CN12
CN6
CN3
CN2
CN11
CN14
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
ANION GENERATOR
STEPPER MOTOR
STEPPER MOTOR
RED
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
RED
RED
BLACK
BLACK
WHITE
WHITE
WHITE
BROWN
BROWN
GRAY
GRAY
PINK
PINK
PINK
YELLOW
YELLOW
YELLOW
ORANGE
ORANGE
ORANGE
LED POWER
LED
1367356-T01-A

-3-
+
+
+
+
+
+
There's no risk of damage to the insulation of power cord.
Copper cord must be inserted into the pillar terminal hole, and make
sure all the cords under the terminal are inserted into the pillar
terminal completely.
Suggest using a power cord which with specification 60227 IEC 53
Model's powercord Specified in GB/T 5023.5 and with cross section
of 3X1.5mm .
,
GB/T 5023.5 60227 IEC 53 ,
3X1.5mm
2
2
Terminal
Conductor
Insulation 8
(Unit: mm)
(: )
WARNING
Make sure the power cord installed firmly,
otherwise it may catch fire.
Conductor
Earth
Power Cord
8
8
13 10
K-21465T-0
K-21463T-X-0
MAIN CONTROL CIRCUIT BOARD
ALL-POLE SWITCH (OPTIONAL)
220V
50Hz
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 20A
250V 20A
HOT MOTOR
VENT MOTOR
YELLOW/GREEN
/
HEATER 1 1
HEATER 2 2
THERMOSTAT
THERMAL FUSE
OVER CURRENT FUSE
CAPACITOR
CAPACITOR
CN4
P5
P4
P3
P2
P1
CN7
CN8
CN5
CN12
CN6
CN3
CN2
CN11
CN14
STEPPER MOTOR
STEPPER MOTOR
RED
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
BLACK
WHITE
WHITE
WHITE
BROWN
BROWN
GRAY
GRAY
PINK
PINK
YELLOW
YELLOW
ORANGE
ORANGE
LED POWER
LED
MAIN CONTROL CIRCUIT BOARD
ALL-POLE SWITCH (OPTIONAL)
220V
50Hz
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 20A
250V 20A
HOT MOTOR
VENT MOTOR
YELLOW/GREEN
/
HEATER 1 1
HEATER 2 2
THERMOSTAT
THERMAL FUSE
OVER CURRENT FUSE
CAPACITOR
CAPACITOR
CN4
P5
P4
P3
P2
P1
CN7
CN8
CN5
CN12
CN6
CN3
CN2
CN11
CN14
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
ANION GENERATOR
STEPPER MOTOR
STEPPER MOTOR
RED
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
RED
RED
BLACK
BLACK
WHITE
WHITE
WHITE
BROWN
BROWN
GRAY
GRAY
PINK
PINK
PINK
YELLOW
YELLOW
YELLOW
ORANGE
ORANGE
ORANGE
LED POWER
LED
CLOUD
COMMUNICATION
ASSEMBLY
RED
WHITE
WHITE
WHITE
WHITE
1367356-T01-A

-4-
PREPARATIONS BEFORE INSTALLATION
A. Preparation before the installation A.
1. Open the hole of outlet window
Make sure that the outlet window s position (it should be
lower than the outlet of the bathroom heater to prevent the
water come back to the bathroom heater from the outlet
window), and open a round hole on the wall.
2. Outlet window installation
Fix the air exhaust pipe to the outlet window on the wall
with the clamp as the preparation of bathroom heater
installation. Seal the pipe and the outlet window with
foaming agent.
1.
(
)
2.
Ceiling
Air Exhaust Pipe
Wall
Inner Wall Outer Wall
Outlet Window
Outer wall installing. Inner wall installing.
Outlet Window
Outlet Window
Hole on the Wall Hole on the Wall
120mm
120mm
110mm
110mm
B. Take out the bathroom from package. B.
Bathromm Heater
1367356-T01-A

1367446
100 Air Outlet Window
100
1367447
100 Air Exhasut Pipe
100
1285549
Clamp
2
1367441
Fixed Column Assy.
M6 Expansion Head
M6
10 Expansion Pipe
10
M6 Screw Rod
M6
1285553
Lock Assy. /
M6 Butterfly Nut
M6
6 Washer
6
6Spring Washer
6
M6 Nut
M6
Note: Initial Length: 140mm
Stretch Length: 2000mm
140mm
2000mm
305mm
C. Packing List C.
-5-
Remote Control
(Only K-21465T-0)
( K-21465T-0)
Remote Control
(Only K-21463T-0/
K-21463T-X-0)
( K-21463T-0/
K-21463T-X-0)
1367444
Installation Template
S600
1367445
Ventilation Outlet Assy.
S600
1285551
Heater Accessories Assy.
Hanger
Triangular
Self-tapping Screw
BTP4*8
BTP4 8 Triangular
Self Tapping Screw
BTP4 8
Cover
*2
Cover
*2
M4*25 Screw
*2
M4*25 Screw
*2
Base
Base
6 Plastic
Expansion Pipe
6*2
6 Plastic
Expansion Pipe
6*2
Remote Control Base Assy.
Remote Control Base Assy.
1367443
Remote Control Assy.
1367442
Remote Control Assy.
1367356-T01-A

-6-
INSTALLATION
Caution before installation:
!
!
!
!
!
!
The installed product must be 200mm or above away from
curtains or other combustible materials.
The distance between the ceiling where the product is
mounted and the roof shall be 200mm or above.
Ensure that the gap between the product edge and the
wall is 300mm or above.
The power cord to the product shall have enough length
for the installation.
The distance between the product and the air outlet
window shall be 2000mm or lower.
Cut the screw rod(M6) to suit the distance between the
ceiling and the roof.
!
!
!
!
!
!
200mm
200mm
300mm
2000mm
(M6)
Air Exhaust Pipe
Wall
Under 2000mm
2000mm
Above 300mm
300mm Above 300mm
300mm
Air Outlet Window
1. Connecting the power cord
(1) Pass the power cord through the ceiling.
1.
(1)
Power Cord
Decorated Plate
1367356-T01-A

2. Fix the power cord to the bathroom heater
(1) Remove the screw on the wiring cover plate.
(2) Open the wiring cover plate.
(3) Lift the terminal protection cover.
(4) Loosen the screw fixing the power cord clip.
(5) Loosen the screw on the wiring terminal, insert the
power cord (not supplied) connected to the indoor fixed
line into the wiring terminal, tighten the wring terminal
screw.
(6) Fix the power cord with power cord clips. (The power
cord clip must pin the insulation sheath of power cord.)
(7) Use the screw removed in step (1) to fix the wiring
cover plate again.
2.
(1)
(2)
(3)
(4)
(5) (
)
(6) (
)
(7) (1)
Power Cord
NL
Wiring Terminal
3. Installing the Main Body Method 1 integrated ceiling.
integrated ceiling should be 300*300, 300*450, 300*600
(1) Disassembly the decorated plate around the position of
the product installation.
3.
300*300 300*450 300*600
(1)
()
300mm*300mm integrated ceiling
300mm*300mm
Disassembly 6 pieces
6Disassembly 6 pieces
6
300mm*450mm integrated ceiling
300mm*450mm
300mm*600mm integrated ceiling
300mm*600mm
Disassembly 3 pieces
3
-7-
(2) Bend the installation template to 90 at the bending line.
Push the template to the location of fixed hole A in the
ceiling as the diagram shows.
°(2) 90
A( )
300mm*300mm integrated ceiling
300mm*300mm
Bending Line
Install Template
Install Template
Install Template
Install Template
Install Template
Install Template
Cement Board
Cement Board
Ceiling
Drill Position
Fixed Hole A
A
Drill Position
600
580
200
300
Bottom View
Bottom View
1367356-T01-A

-8-
(3) Fix the suspender on the right position of the cement
board, use the install template to adjust the M6 nut on
the suspender.
(4) Fix the suspension bracket on the suspender by 8
BTP4*8 screw.
(3)
M6
(4) 8 BTP4*8
M6 Butterfly Nut
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
M6 Nut
M6
BTP4*8 Triangular Self Tapping Screw
BTP4*8 (8 )
Suspender
Cement Board
Ceiling Surface Install template datum line
(5) Fix the product on the M6 suspender by the suspension
bracket.
(5)
M6 Butterfly Nut
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
Hanger
*4
1367356-T01-A

-9-
(6) Install the air exhaust pipe
1) Fix the air exhaust pipe on the ventilation outlet assy.
by the clamp. The pipeline connected to outside of
the room must be slanted to prevent rain or
condensed water from flowing backwards.
(6)
1)
Outdoors
Indoors
Slant Taper 1
100
1
50
~
()
BTP4*8 Triangular
Self Tapping Screw
BTP4*8 (1 )
Ventilation Outlet Assy.
Ventilation Outlet Assy.
Clamp
Air Exhaust Pipe
(7) Install the decorated plate and adjust the nut on the
suspender to keep them on the same horizontal surface.
Lock the nut after the adjustment.
(8) Install the remaining decorated plate (finish the product
installation)
(7) M6 M6
(8) ( )
300mm*300mm integrated ceiling
300mm*300mm
1367356-T01-A
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali Kohler Stufa

Kohler
Kohler K-77316T-MZ Manuale utente

Kohler
Kohler S300 Manuale utente

Kohler
Kohler K-77283T-2-MZ Manuale utente

Kohler
Kohler K-77316T-C-MZ Manuale utente

Kohler
Kohler PA-253213 Manuale utente

Kohler
Kohler S300G Manuale utente

Kohler
Kohler S300 Manuale utente

Kohler
Kohler S300GP Manuale utente

Kohler
Kohler S450 Manuale utente

Kohler
Kohler S300P Manuale utente
Manuali Stufa popolari di altre marche

Empire Heating Systems
Empire Heating Systems WCC65 Manuale utente

Wetekom
Wetekom 92 86 43 Manuale utente

Desa
Desa SPC170-F Manuale utente

Watlow
Watlow Watrod Electric Tubular Heaters Manuale utente

Haverland
Haverland ECO-DRY GPS Series Manuale elenco delle parti

Stelpro
Stelpro ASILVC2060 Series Manuale utente